City Technology Gas Sensors (CiTiceL & CiTipeL)

UK-engineered CiTiceL electrochemical cells and CiTipeL catalytic pellistors for O2, CO, toxic, and LEL gas analyzers (5FO, 2FO, AO2, 4P-90C, 4P-75C, 4CFC, ECO-Sure 2e).

5FO / 5 Series — Flue Gas Sensors

5FO CiTiceL (AAA32-400) measures 0-25% vol. O2 with a 30% vol. overload in flue gas analyzers. Output signal reaches 0.41 mA in air with T95 under 20 seconds. Bayonet mounting fits 5 Series monitors for CO, NO, NO2, and SO2. PCB socket connections prevent thermal pin damage.

  • 5FO CiTiceL (AAA32-400): 0-25% vol. O2, 0.41 ± 0.05 mA
  • T95 < 20 s, 100 Ohm max load, bayonet fitting, 44 g
  • Operating range -20°C to +45°C, 2-year life in air
  • 5 Series line covers O2, CO, NO, NO2, SO2, and H2-comp. CO

2FO / AO2 — Automotive & Emissions O2

AO2 CiTiceL (AA428-210) partial-pressure cell measures 0-100% O2 in exhaust gas analyzers. Output is linear at 9-13 mV in air with T90 under 5 seconds. Red ABS enclosure integrates a 3-pin Molex header. 2FO monitors 0-25% O2 alongside AO3 and NX1.

  • AO2 (AA428-210): 0-100% O2, 9-13 mV, T90 < 5 s, 40 g
  • 3-pin Molex 22-29-2031, external load ≥ 10 kOhm, red ABS
  • 2FO: 0-25% vol. O2 for ambient and emissions monitoring
  • Rated life 360,000 % O2 hours at 20°C or 2 years in air

4P90C / 4P75C / 300PZ — CiTipeL Pellistors

4P90C CiTipeL (PM463-000, 3.3 Vdc) and 4P75C CiTipeL (PM483-000, 3.0 Vdc) catalytic bead sensors measure 0-100% LEL combustible gases in 316 stainless steel housings with enhanced H2S and silicone poison resistance. 300PZ runs at 2.0 Vdc. Bridge voltage must match.

  • 4P90C (PM463-000): 3.3 Vdc, 75 mA, 28 mV/% methane
  • 4P75C (PM483-000): 3.0 Vdc, 263 mW max, 24 mV/% methane
  • 300PZ (PM792--000): 2.0 Vdc, 280 mA, KOVAR pins, T90 < 15 s
  • 0-100% LEL methane/propane/H2, H2S filter 1000 ppm·h

4CFC / 4CF+ — 4-Series CO CiTiceL Sensors

4CFC CiTiceL (2112B2006, 0-1000 ppm CO) and 4CF+ CiTiceL (2112B2005, 0-500 ppm CO) are 3-electrode electrochemical cells with built-in filters for acid gases and hydrocarbons using a 5 Ohm load resistor. Overload reaches 2000 ppm. PCB socket mounting is mandatory.

  • 4CFC (2112B2006): 0-1000 ppm CO, overload 2000 ppm CO
  • 4CF+ (2112B2005): 0-500 ppm CO, 0.07 ± 0.015 µA/ppm
  • 5 Ohm load resistor, T90 < 20 s, Noryl 110 enclosure, 5 g
  • Continuous -20°C to +40°C, 2-year life in air, no bias

ECO-SURE 2E / X — Long-Life CO Sensors

ECO-SURE (2E) (2112B3000) and ECO-SURE X (2112B3001) are 2-electrode electrochemical CO sensors for fire detection and ventilation control. Operating life exceeds 6 and 10 years. Sensitivity is 45-50 nA/ppm into a 5 Ohm load with UL2075 recognition.

  • ECO-SURE 2E (2112B3000): 0-500 ppm CO, 45 ± 15 nA/ppm, > 6 yrs
  • ECO-SURE X (2112B3001): 4-500 ppm CO, 50 ± 10 nA/ppm, > 10 yrs
  • 5 Ohm load resistor, 1000 ppm overload, T90 < 30 s
  • Noryl N110 housing, 5 g nominal, UL2075 component recognition

1series / iseries — Slim & Digital Sensors

1series compact square cells (1CO, 1H2S, lead-free 1O2, 1SO2, LEL) cut sensor height to one third with a 5-year operating life. Digital iseries iCO (AB010-R01D-CIT) uses a 3.1-3.3 V UART protocol. Pre-calibration and fault alerts simplify field swaps.

  • 1series: 1CO, 1H2S, lead-free 1O2, 1SO2, LEL, 5-year life
  • Surface-mount spring contacts and replaceable outer membrane
  • iseries iCO (AB010-R01D-CIT): UART 3.1-3.3 V, 0-1000 ppm CO
  • Pre-calibrated output, OEM lock codes, predictive alerts

Industrial Applications of City Technology Gas Sensors

Founded in Portsmouth, UK, and now part of Honeywell Industrial Automation, City Technology manufactures CiTiceL electrochemical cells and CiTipeL catalytic pellistors across more than 300 models detecting 28 gases for portable, fixed, and emissions analyzers.

Portable safety monitors rely on 4-Series and slim 1series sensors, flue gas analyzers use 5-Series cells such as 5FO, automotive exhaust benches deploy AO2 and 2FO, while OEM instruments integrate UART-based digital iseries iCO modules.

Electrical Matching and PCB Installation Rules

Catalytic pellistors require exact bridge excitation matching: 3.3 Vdc for 4P90C (PM463-000), 3.0 Vdc for 4P75C (PM483-000), and 2.0 Vdc for 300PZ (PM792--000). Electrochemical CO cells 4CFC and ECO-SURE operate into a 5 Ohm load resistor with zero bias.

All pin-type CiTiceL sensors must plug into PCB sockets rather than direct solder joints, as soldering heat damages seals. For AO2 Molex-equipped sensors, tighten only by hand to protect the housing thread.

Storage Life and Poison Protection

Sealed storage life is 6 months from dispatch at 0-20°C for 5FO and CiTipeL pellistors, or 10-30°C for 4CFC and ECO-SURE CO cells. Integrated filters in 4CFC and iCO scrub acid gases and interfering hydrocarbons.

Perform PCB degreasing before fitting sensors and prevent exposure to solvent vapors, adhesives, and volatile silicones such as HMDS that poison catalytic beads.

City Technology and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of City Technology and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.