TEIKOKU canned motor pumps and spare parts

Source TEIKOKU canned motor pumps by operating duty and liquid properties. Send the model and assembly drawing for spare parts.

Basic F pumps

The F type serves low to medium temperature liquids without suspended solids. The pump and motor form one close-coupled unit. A TRG meter helps monitor bearing wear.

  • Liquids without solids
  • Austenitic stainless steel wetted parts
  • TRG bearing monitoring
  • Duty point selection

F-M, R-M and B-M multistage pumps

Multistage pumps address high head duties. The impellers are arranged in opposing pairs to balance axial thrust. Include the full type code in an enquiry.

  • High head duty
  • Opposing impeller pairs
  • Axial thrust balance
  • Section drawing check

R reverse circulation pumps

The R type serves volatile liquids. The circulation flow lubricates the bearings and cools the motor. It returns to the vapour space of the supply vessel.

  • Volatile liquid duties
  • Motor cooling flow
  • Bearing lubrication
  • Return to vapour space

B high temperature separation pumps

The B type uses liquid cooling and separates the high temperature section. Applications include hot water and heat transfer fluids. Include cooling conditions when specifying a unit.

  • Hot water duty
  • Heat transfer fluids
  • Liquid cooling
  • Piping review

G self-priming pumps

The G type provides a self-priming arrangement. It can start pumping before the suction line fills completely. Record the installation elevation and start conditions.

  • Self-priming arrangement
  • Start conditions
  • Installation elevation
  • Suction layout review

K jacketed pumps

The K type handles liquids with a high melting point and a tendency to crystallise. A jacket is part of the arrangement. State the temperature maintenance requirements when requesting a quotation.

  • Jacketed arrangement
  • Crystallising liquids
  • Temperature control
  • Heating circuit review

D fine-slurry pumps

The D type serves liquids carrying a small amount of fine solids. A mechanical seal separates the process liquid from fluid on the motor side. An external clean flush lubricates the bearings.

  • Fine solids
  • Mechanical seal
  • External clean flush
  • Solids data required

SG and XG gas chamber pumps

SG and XG handle slurries with a relatively high solids content. A gas chamber separates the process liquid from the motor. Provide solids concentration and particle size data for selection.

  • Higher solids content
  • Gas separation chamber
  • Solids concentration
  • Particle size data

Canned motor pump selection

For a TEIKOKU pump quotation, specify flow, head, operating temperature and liquid composition. If the process has several modes, give each operating point on its own line, with the paired flow and head and the expected duration.

Distinguish measurements on an existing plant from values calculated for a new project. Supply the source vessel arrangement, the level range and the expected pressure above the liquid so that the suction conditions can be reviewed.

Include the intended operating frequency when a drive controls motor speed.

On a new system, mark which nozzle orientations and installation dimensions can still be changed. On a replacement, identify the fixed interfaces, access for lifting and the maintenance clearance available after the pump is installed.

State whether the duty unit and the standby unit run under the same suction conditions. If they share a line, include a drawing showing how the line is switched.

Liquid properties and circulation

The F family handles low to medium temperature liquids without suspended solids. For volatile duties the R arrangement returns the circulation stream to the vapour space of the vessel. In an R enquiry, show the return connection and the normal and limiting liquid levels.

Include the temperatures and vessel pressures associated with each mode, especially when the liquid is near a change of phase.

If composition varies between batches, specify the concentration range, any impurities and the cleaning medium used to flush the system. Identify what remains in the circuit during standby. Ask for the wetted material schedule against the offered model.

Check the specified material against both the pumped product and the cleaning liquid used during operation or maintenance.

Hot liquids and crystallising duty

The B type is a liquid cooled high temperature separation design for hot water and heat transfer fluids. The jacketed K arrangement serves liquids with a high melting point that can crystallise. Provide a separate set of parameters for the process stream and for each utility circuit.

Where viscosity changes substantially with temperature, attach the available data over the expected range.

For a cooling service, state the supply conditions and available return route. For a heating jacket, identify the heating medium and the conditions maintained while the pump is idle. Obtain a general arrangement drawing with auxiliary connections marked before completing the piping design.

If part of the utility system is already installed, mark the available connection points and the limits of the new equipment supply.

Suspended solids and clean flush

The D type serves liquids containing a small amount of fine solids and uses a mechanical seal and an external clean flush. SG and XG use a gas chamber between the process liquid and the motor. For a slurry enquiry, identify the particle material, size distribution, density and solids concentration.

Specify whether the concentration is by volume or by mass. Describe how the product behaves after standing and whether the pump can encounter a settled layer after a shutdown.

For the D arrangement, supply the available flush liquid data and state whether it can contact the product. If the flush source is shared with other equipment, identify the conditions that must be met when those consumers are running.

For an SG or XG proposal, compare the offered assembly and connections with the plant drawing. Include the batch change and cleaning conditions when agreeing the materials.

High head and self-priming applications

F-M, R-M and B-M are multistage arrangements for high head duties. Opposing impeller pairs balance axial thrust. Include the system curve and list the operating points the pump has to cover.

For a plant with parallel process lines, show which branches can operate together and the sequence in which they are brought into service. Provide any outlet pressure requirements and the basis for the specified head.

The G type is designed to self-prime when the suction line is not completely filled. State the installation elevation, the suction pipe arrangement and how the plant prepares the pump for starting. Compare the proposed starting arrangement to the conditions in the manufacturer documentation.

In a constrained installation, identify where the suction and auxiliary pipes can be inspected or removed for maintenance.

Mechanical and electrical interfaces

Send base dimensions, nozzle orientation and any lifting restrictions for the site layout. Identify which connections have to match existing pipework and where maintenance staff need room for removing a pump or a monitoring device.

For an installed line, mark the actual locations of mating flanges and supports on a dimensioned sketch. A photograph is useful for locating obstacles and the sketch supplies the dimensions needed for checking fit.

State supply voltage, frequency and site protection requirements separately from the motor information. Identify the control signals available at the panel. If a monitoring device is required, describe how readings and alarms will be handled by the site system.

Record who supplies cables, sensors, auxiliary valves and counterflanges before the equipment drawing is approved.

Spare parts and monitoring devices

For bearings, impellers and monitoring devices, include the pump nameplate, serial number and the position number on the assembly drawing. Add a photograph of the device label and its connection if the item being sourced is a monitoring instrument.

The manufacturer describes TRG bearing wear monitoring for the basic F pump. Verify a proposed device against the documentation for the installed equipment.

For an enquiry covering several pumps, list the units separately even when the series marks match. State quantity and required documents for each item. When purchasing a complete replacement, specify whether commissioning spares belong in the pump package.

For planned maintenance stock, provide the equipment duty and list the positions already held on site. Record any revisions in the pump drawings since the equipment was received.

Enquiry package and delivery acceptance

Provide quantities, country of delivery, installation limits and the document schedule with the enquiry. For a staged delivery, list the pumps and accessories that belong to each shipment.

If shared components are being procured for more than one plant, identify the destination of each item and whether common packing is allowed. For an installation assembled on site, check that the packing sequence supports the intended order of work.

Before approving the order, compare the proposed pump code, interface drawing, auxiliary connection schedule and identification marking against the equipment list. State which checks are required before dispatch and which will be performed on receipt.

Attach the project test or inspection form if it has already been specified. Have the agreed drawing and purchase specification available when checking the equipment on arrival.

TEIKOKU and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of TEIKOKU and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.