KEB (KEB Automation KG) drive technology and automation
Source COMBIVERT drives, motors, brakes and control components for industrial equipment. Select the configuration against the motor, duty and machine design.
COMBIVERT F6 drive controllers
F6 combines variable-frequency and servo functions. Select the power unit for the enclosure and cooling arrangement. Verify the control board and feedback interface for the installed motor.
- Motion control
- Power unit
- Control board
- Cooling arrangement
COMBIVERT S6 servo drives
S6 serves controlled axes with motor feedback. The drive supports brake handling. Check the feedback interface and control inputs alongside the machine controller configuration.
- Servo drive
- Motor feedback
- Brake handling
- Control inputs
G6 and F5 inverters
COMBIVERT G6 regulates motor speed. F5 is a multipurpose drive family. A retrofit starts with a comparison of output current, mounting dimensions, control and duty cycle.
- G6 inverter
- F5 drive
- Output current
- Duty cycle
COMBIVERT H6 multi-axis systems
H6 axes share a DC link. The system configuration depends on the motor and the role of each axis. Match the supply and axis modules against the cabinet design.
- Supply module
- Axis module
- Common DC link
- Cabinet design
COMBILINE filters and chokes
COMBILINE covers E6 EMC filters and chokes. Identify where the component sits in the circuit. Match mains filters to supply and drive current, and output components to the motor and cable route.
- E6 EMC filter
- Choke
- Mains connection
- Motor cable
TA series servomotors
Select TA servomotors for the axis load. A replacement must match the flange, shaft and connector. Check the motor feedback and brake option against the assembly drawing.
- TA family
- Flange and shaft
- Motor connector
- Brake option
COMBISTOP brakes and clutches
COMBISTOP spring-applied brakes hold the mechanism when the coil is de-energised. Check torque, coil voltage and shaft fit for a replacement. Identify where a clutch transfers torque in the mechanism.
- Spring-applied brake
- Coil
- Braking torque
- Shaft fit
C6 Remote I/O modules
C6 Remote I/O connects machine signals. Identify the channel type and station layout before replacing a module. Verify terminals, power supply and head module against the control project.
- Remote I/O
- Signal channels
- Terminal block
- Head module
Selecting a KEB drive
Select the controller against the motor, motion cycle and machine interface. Begin with a single axis and its intended work. A fan that runs for hours at a steady setpoint presents a different load from a moving carriage with frequent reversals.
Record the duration of acceleration, travel, deceleration and dwell. Include the expected workpiece or payload and any mechanical transmission. Ask the machine designer to define the production cycle if the motor rating is the only data available.
For an installed machine, compare the proposed controller against the equipment already in use. Its full designation and configuration provide a starting point for identifying the supply, feedback and control options.
A new machine requires agreement between the panel designer and the mechanical team. Define the limits of the purchased assembly before comparing offers for combinations of controller, motor and brake.
G6, F6 and S6 applications
Consider COMBIVERT G6 for a speed-regulated motor application. Where the machine needs dynamic motion or controlled positioning, assess the appropriate F6 or S6 configuration.
Define the command path from the machine controller, the source of speed or position demand, and the feedback required for the machine sequence. A fieldbus connection and a hardwired arrangement call for different interface checks.
Current and overload capability depend on the selected execution and on the load cycle. Verify the exact device rather than inferring the limits from the family name. For a retrofit from an older F5 unit, identify the parameters the original machine uses.
Compare status signals, terminal functions and the motor feedback. If the machine uses the original controller programme, a change in signal names or behaviour can affect startup and recovery.
Motor and mechanical fit
Assess the motor with its transmission and the load. For a geared axis, check ratio and mounting orientation, as well as shaft loading and the direction of useful motion. For a directly coupled motor, compare the flange, shaft and coupling dimensions.
Look at space around the connectors and the direction of cable exit. Space allocated to the motor body is only one part of the installed envelope.
Confirm the feedback device, signal connection and holding brake against the electrical design. Record which cables belong to the motor and which are routed through a moving carrier. A replacement with the same flange may still require a different harness.
Plan the practical cable route before ordering a motor for equipment that is difficult to reach, such as a vertical slide or an enclosed handling axis.
Multi-axis H6 arrangements
The H6 system couples the axis modules through a common DC link. Its supply module should be selected with a view of the entire machine sequence. A listing of motor ratings does not show which axes accelerate together or which are decelerating while the others draw power.
Identify simultaneous moves and the consequences of an axis losing its supply. For an extension, collect the module identities and the cabinet drawing before ordering a new axis.
The system architecture also determines whether cooling, connections and physical order match the intended panel layout. For a replacement, compare the axis unit and the surrounding modules with the specified assembly.
For a new project, clarify the supply boundary and the items delivered as part of the cabinet. Verify access for inspection and replacement after the cabinet is wired.
Holding brakes and deceleration
Distinguish mechanical holding from drive-controlled deceleration in the design brief. When selecting a COMBISTOP brake, specify the holding requirement, the coil supply and the attachment geometry. Check whether the proposed execution is intended for the specified operating and emergency duty.
For a vertical axis, define how the mechanism is supported when de-energised and which machine logic controls release.
Assess electrical braking from the motion cycle and the route by which energy leaves the drive. A braking resistor or energy recovery equipment must fit the circuit and the repetitive duty. Note which parts of the braking arrangement are included in the order and which are external.
Where braking accessories are supplied as a kit, list their actual ratings alongside the drive configuration.
Filters, chokes and cabinet space
For COMBILINE, establish whether the component is on the mains side or the motor side. The electrical design, cable route and applicable compatibility requirements inform the selection. A mains filter should be checked with the intended supply and drive.
An output component is selected in relation to the motor and cable. Use the circuit drawing to establish the position of an installed device before selecting a replacement.
When the panel already exists, review the available enclosure depth, ventilation paths and clearances for wiring. Leave room for the termination work and any fastening tools.
When a separate filter is proposed for a drive upgrade, check its installation arrangement, electrical data and continued access. This early review avoids finding that the installed assembly cannot be serviced with the panel in place.
Machine control and I/O
For C6 Remote I/O, start with a channel schedule. List the sensor or actuator function, signal type, terminal allocation and expected state on loss of supply. Match the station head and communication interface with the intended control system.
When one module is replaced, compare the position and type of its channels against the existing configuration.
For a new station, compare the channel list with the rest of the machine project before releasing the order. Some circuits are used for process status, while others request motion or provide confirmation that an operation is complete.
Agree which devices and connection materials will be supplied and how the configured machine will be verified. A complete schedule makes it possible to compare the ordered modules with the wiring diagrams during installation.
Defining the equipment order
For a single replacement, supply the exact designation, application and available documentation. For a system build, include the drive, motor, brake, filtering and control items required by the machine drawing.
This identifies where an accessory belongs and makes it easier to see whether an offer meets the required scope. Where only part of the designation remains legible, reference photographs and the cabinet drawing help recover relevant configuration information.
For a multi-machine installation, check whether all cabinets use the same execution. Machines that look alike may use different connector sets or control programme versions. List the units with any meaningful differences and identify which spare parts can serve more than one machine.
Agree which mechanical and electrical dimensions can be checked on delivery and which interfaces will be validated after installation.
KEB and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of KEB and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.