Milestone microwave sample preparation and mercury analyzers
Technical selection of Milestone equipment: ETHOS, ultraWAVE and ultraCLAVE microwave digestion systems, DMA-80 evo and DMA-1 evo mercury analyzers, the ETHOS M muffle furnace and clean chemistry tools.
ETHOS microwave digestion system
ETHOS is a rotor-based microwave digestion system; with accessories it also runs solvent extraction, evaporation and high-temperature processes. The housing is stainless steel and the door stays locked until a user-set temperature. The easyTEMP sensor tracks temperature.
- Easy, Up and Plus terminals
- Plus display 10.1 in
- SafeVIEW camera on Up and Plus
- easyTEMP contactless sensor
ETHOS LEAN compact labstation
ETHOS LEAN, now in its second series, is a compact labstation for digestion and solvent extraction. Rotors shown include MAXI-14 with 14 positions and large-volume PTFE vessels, SK-6 with six vessels for reactive samples, and MAXI-14 HP for higher temperatures and pressures.
- MAXI-14 rotor: 14 positions
- SK-6 rotor: 6 vessels
- MAXI-14 HP: 14 positions
- ultraFAST option: up to 1200 °C
ultraWAVE single reaction chamber systems
In the ultraWAVE 2 eco and ultraWAVE 3 all samples digest together in one PTFE-lined stainless-steel chamber pre-pressurized with inert gas. The 2 eco uses an internal thermocouple and air cooling; the ultraWAVE 3 has a contactless temperature sensor and a water-cooling circuit.
- One SRC chamber for all samples
- ultraWAVE 3: racks up to 40 vials
- 2 eco: PTFE, quartz, glass vials
- 2 eco: air cooling
ultraCLAVE automated digestion system
ultraCLAVE digests up to 77 samples in one SRC reactor at up to 300 °C and up to 200 bar. The stainless-steel reactor exceeds 4 L and holds a 3.5 L PTFE vessel. The system closes the reactor and loads nitrogen pressure on its own; an external chiller cools the vials.
- Temperature up to 300 °C
- Pressure up to 200 bar
- Racks up to 77 positions
- PTFE vessel 3.5 L
DMA-80 evo mercury analyzer
The DMA-80 evo measures mercury directly in solid, liquid and gas samples with no sample preparation. Mercury is trapped on a gold amalgamator and released into multiple measuring cells; cuvettes are held at 120 °C against condensation. The carrier is compressed air or oxygen.
- Solid, liquid and gas samples
- Cuvettes at 120 °C
- 40-position plates
- Carrier: air or oxygen
DMA-1 evo compact mercury analyzer
The DMA-1 evo is a compact standalone mercury analyzer with an integrated terminal for labs with limited mercury throughput. Solid and liquid samples are weighed into metal or quartz boats. The easyCONTROL software supports Auto-blank, LIMS connection and data import and export.
- Metal or quartz boats
- Solid and liquid samples
- Integrated terminal
- LIMS connection
ETHOS M microwave muffle furnace
ETHOS M replaced the former PYRO system and handles ashing, sulfated ashing, loss on ignition, residue on ignition and fusion. Two magnetrons heat a silicon carbide element in the muffle; a Venturi exhaust supplies air. The muffle comes in three interchangeable configurations.
- Up to 18 crucibles
- Two magnetrons
- Three muffle configurations
- Venturi exhaust
Clean chemistry and dosing
subCLEAN purifies HF, HNO3 and HCl by sub-boiling distillation with fluoropolymer wetted parts, air-cooled. duoPUR has two quartz units with infrared heating, typically 20 °C below boiling. traceCLEAN steam-cleans labware in about an hour; easyFILL doses up to six reagents.
- duoPUR: 2 quartz units
- 20 °C below boiling point
- traceCLEAN cycle about 1 hour
- easyFILL: up to 6 reagents
Choosing a Milestone sample preparation system
Milestone was established in 1988; Milestone SpA is headquartered in Sorisole (Bergamo, Italy) with offices in the United States, China, Japan and Korea, and its R&D and manufacturing sites are in Germany (MLS) and Switzerland (MWS).
The maker site shows, among others, the ETHOS and ETHOS LEAN rotor-based microwave digestion systems, the ultraWAVE 2 eco, ultraWAVE 3 and ultraCLAVE single reaction chamber systems, the DMA-80 evo and DMA-1 evo mercury analyzers, the ETHOS M muffle furnace and clean chemistry tools.
Rotor-based system or SRC chamber
In the rotor-based ETHOS and ETHOS LEAN each sample is digested in its own PTFE-TFM vessel inside a protective shield.
The rotor is chosen by vessel count and volume; ETHOS rotors shown by the maker include the SK-15 (up to 15 vessels of 100 mL) and the MAXI-44 (up to 44 vessels of 100 mL), and ETHOS LEAN rotors include the MAXI-14, SK-6 and MAXI-14 HP.
In SRC systems all vials sit in one chamber under shared gas pressure: the ultraWAVE 3 takes racks of 7, 20, 27 and 40 vials; the ultraCLAVE digests up to 77 samples at up to 300 °C and up to 200 bar, with a cycle of about 60 minutes for 40 or 77 samples.
Extraction, synthesis and ashing
ETHOS X handles 24 samples in 40 minutes for solvent extraction, with sample amounts up to 30 g. For synthesis, the synthWAVE uses a 1 L PTFE-lined stainless steel chamber at up to 300 °C and up to 199 bar; the flexiWAVE has two 950 W magnetrons, a cavity over 70 L and up to 15 high-pressure vessels.
The ETHOS M microwave muffle furnace replaced the former PYRO system: ashing, sulfated ashing and fusion, up to 18 crucibles, three interchangeable muffle configurations.
Milestone and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Milestone and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Biotage
- Equipment and parts for SOTAX
- Equipment and parts for Wyatt Technology
- Equipment and parts for Nanalysis
Documents and sources
- About Milestone — history and sites
- Milestone contacts — Sorisole head office
- milesCARE support program — maker service
- ETHOS system — rotors and terminals
- ETHOS LEAN labstation — rotors
- ultraWAVE 2 eco — SRC chamber
- ultraWAVE 3 — racks and cooling
- ultraCLAVE — pressure and temperature
- DMA-80 evo mercury analyzer — design
- DMA-1 evo mercury analyzer — design
- ETHOS M muffle furnace — configurations
- subCLEAN acid purification — sub-boiling
- duoPUR and subPUR — quartz units
- traceCLEAN — acid steam cleaning
- easyFILL dosing station — reagents and racks
- ETHOS X extraction — throughput
- synthWAVE synthesis — chamber and limits
- flexiWAVE synthesis — magnetrons and cavity