Wyatt Technology light scattering instruments
Selection of Wyatt instruments: DAWN, omniDAWN, miniDAWN and ultraDAWN MALS detectors, Optilab refractometers, ViscoStar viscometers, DynaPro DLS instruments, Eclipse and Calypso systems.
DAWN MALS detector
Multi-angle light scattering detector for SEC-MALS and FFF-MALS with photodiodes at 18 angles and molar mass from 200 Da to 1 GDa. Options are a heated/cooled model from -15 to +150 °C, a UHT model up to +210 °C and a 785 nm laser for fluorescing samples. A built-in COMET unit cleans the cell.
- 18 detection angles
- Molar mass 200 Da to 1 GDa
- H/C option: -15 to +150 °C
- UHT option: up to +210 °C
omniDAWN UHPLC detector
The omniDAWN multi-angle light scattering detector is built for UPLC and UHPLC systems. It uses 18 scattering angles and measures molar mass from 200 Da to 1 GDa. The System Ready Monitor shows system status on the front panel, and an integrated ultrasonic module cleans the cell in situ.
- UPLC and UHPLC systems
- 18 scattering angles
- Molar mass 200 Da to 1 GDa
- In situ ultrasonic cleaning
miniDAWN detector
Three-angle multi-angle light scattering detector for SEC: molar mass from 200 Da to 10 MDa for proteins or up to 1 MDa for linear polymers, ambient temperature only. Faulty modules are replaced and validated on site without realignment, and the WyattQELS DLS module is also installed on site.
- 3 detection angles
- Proteins: up to 10 MDa
- On-site module exchange
- WyattQELS DLS module
ultraDAWN real-time detector
ultraDAWN measures multi-angle light scattering in real time right in the process stream: up to 300 measurements per minute and a molar mass range of 1 kDa to 1 GDa. Inline flow is up to 150 mL/min for ultraDAWN and up to 1000 mL/min for ultraDAWN Pilot at 1 cP. Data goes out via OPC-UA.
- Up to 300 measurements/min
- Molar mass 1 kDa to 1 GDa
- Pilot: up to 1000 mL/min
- OPC-UA integration
Optilab RI detector
Differential refractive index detector for SEC-MALS and FFF-MALS: a dRI range of -0.0047 to +0.0047 RIU, temperature control from 4 to 65 °C, a 7.4 µL flow cell volume and a 660 nm light source. The separate Optilab HC version handles protein concentrations up to 180 mg/mL.
- dRI range -0.0047 to +0.0047 RIU
- Temperature 4 to 65 °C
- 7.4 µL flow cell
- Optilab HC: up to 180 mg/mL
ViscoStar viscometer
Online differential viscometer for SEC-MALS-IV measuring the intrinsic viscosity of polymers and proteins. Dynamic range of over 135,000:1, a 6.9 kPa differential pressure range protected against overpressure and temperature control from 4 to 70 °C. Flow: up to 1.5 mL/min aqueous, 3 mL/min THF.
- Dynamic range over 135,000:1
- Temperature 4 to 70 °C
- 6.9 kPa differential pressure
- Aqueous: up to 1.5 mL/min
DynaPro DLS instruments
The cuvette-based DynaPro NanoStar II covers radii of 0.2 to 1000 nm and -10 to +120 °C, with samples from 2 µL in a quartz cuvette and a 658 nm laser. DynaPro ZetaStar adds electrophoretic light scattering for zeta potential, a 785 nm laser and up to 96 samples per autosampler run.
- NanoStar: 0.2 to 1000 nm
- NanoStar: -10 to +120 °C
- ZetaStar: 785 nm laser
- ZetaStar: up to 96 samples
Eclipse FFF system
The Eclipse FFF system separates macromolecules and nanoparticles from 1 to 1000 nm in size with no stationary phase. Cross-flow is regulated from 6.67 to 0.03 mL/min and the wetted path resists pH 2 to 12. The factory-installed DCM option raises detector concentration up to 10 times.
- Sizes 1 to 1000 nm
- Cross-flow 0.03 to 6.67 mL/min
- Resists pH 2 to 12
- DCM option: up to 10x
Choosing Wyatt instruments
Wyatt Technology LLC is a US maker of light scattering instruments headquartered in Santa Barbara, California; its founder and chairman of the board is Dr. Philip Wyatt. In May 2023 the company was acquired by Waters Corporation.
The European unit, Wyatt Technology Europe, is based in Dernbach, Germany.
The line-up covers the DAWN, omniDAWN, miniDAWN, microDAWN and ultraDAWN multi-angle light scattering (MALS) detectors, Optilab refractometers, ViscoStar viscometers, DynaPro dynamic and electrophoretic light scattering instruments, Eclipse field-flow fractionation systems and the Calypso system for CG-MALS.
MALS and concentration detectors
DAWN, omniDAWN and ultraDAWN measure at 18 angles, miniDAWN and microDAWN at 3. DAWN sits downstream of GPC, HPLC or FPLC systems with a molar mass range of 200 Da to 1 GDa; the H/C and UHT models are ordered as options.
omniDAWN covers the same mass range for UPLC and UHPLC, and microDAWN connects to UHPLC-SEC systems. miniDAWN is ambient only.
ultraDAWN goes into the process stream with up to 300 measurements per minute and OPC-UA data output; ultraDAWN Pilot handles inline flow up to 1000 mL/min and is also ambient only.
The Optilab refractometer measures concentration (4 to 65 °C, 7.4 µL cell) and the ViscoStar viscometer measures intrinsic viscosity (4 to 70 °C).
DLS, FFF and CG-MALS instruments
DynaPro NanoStar II measures samples from 2 µL in a cuvette. DynaPro ZetaStar adds zeta potential: electrophoretic light scattering runs from 4 to 70 °C and DLS and SLS from -10 to +120 °C; above 7 mS/cm conductivity it needs the Atlas or a backpressure regulator.
DynaPro Plate Reader measures in 96, 384 or 1536 well plates.
The Eclipse system separates particles from 1 to 1000 nm in size; the DCM module and FFF-SEC switching are factory-installed options, and the Mobility module is an add-on. Calypso II with three syringe pumps works together with a DAWN or miniDAWN detector and is designed for aqueous solutions.
Wyatt Technology and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Wyatt Technology and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Biolin Scientific
- Equipment and parts for Biotage
- Equipment and parts for Infors HT
- Equipment and parts for Alicat Scientific
Documents and sources
- About Wyatt — part of Waters since 2023
- Contact — Santa Barbara headquarters
- Products — line-up overview
- MALS detectors — model comparison
- DAWN detector — specifications
- omniDAWN detector — overview
- miniDAWN detector — specifications
- ultraDAWN detector — specifications
- Optilab detector — specifications
- ViscoStar viscometer — specifications
- DLS and ELS instruments — model comparison
- DynaPro NanoStar — specifications
- DynaPro ZetaStar — specifications
- Eclipse FFF system — specifications
- Calypso system — specifications
- Services and support — maker overview
- Customer support — instrument support lifetime
- Service plans — scope of work
