Biotage flash chromatography, synthesis and evaporation systems
Technical selection of Biotage equipment (Uppsala, Sweden): Selekt, Isolera and Flash 400 flash chromatography systems, Initiator+ and Alstra microwave synthesizers, TurboVap and V-10 Touch evaporators and Extrahera sample preparation workstations.
Biotage Selekt flash chromatography systems
Flash chromatography systems for drug discovery and research labs. The Selekt runs at 1–300 mL/min and up to 30 bar with two column lines and four solvent lines. The Selekt Enkel for routine purification runs at 1–150 mL/min and up to 15 bar with one column line and columns up to 120 g.
- Selekt flow: up to 300 mL/min
- Selekt pressure: 0–30 bar
- Selekt columns: up to 1.85 kg
- UV detector: 200–400 nm
Isolera flash chromatography systems
The Isolera One is a single-channel system for 1–5 purifications per day: 1–200 mL/min, 10 bar and a 200–400 nm or 200–800 nm detector. The Isolera LS is built for scale-up labs: 50–500 mL/min, up to 150 g of sample per run and two 11 mL constant-volume HPFC pumps.
- Isolera One: 1–200 mL/min
- Isolera One: 10 bar
- Isolera LS: up to 150 g per run
- Isolera LS weight: 40 kg
Flash 400 production flash systems
Skid-mounted flash purification for kilogram-scale separations, in Flash 400L and Flash 400M versions. Radial column compression at 80–100 psig, a pneumatic solvent pump up to 6.9 bar and a recommended flow of 2–5 L/min. The system is driven by inert gas and needs no electrical supply.
- Flow: 2–5 L/min
- Compression: 80–100 psig
- Inlet pressure: 6.9 bar
- Weight about 455 kg
Initiator+ microwave synthesizers
A synthesizer for organic chemistry: 40–300 °C, up to 30 bar and reaction volumes of 0.2–20 mL. A 0–400 W magnetron at 2.45 GHz and a 300–900 rpm magnetic stirrer. Manual loading can be upgraded to the Robot Eight for 8 vials or the Robot Sixty for 60 vials.
- Heating: 40–300 °C
- Pressure: 0–30 bar
- Magnetron: 0–400 W
- Stirrer: 300–900 rpm
Initiator+ Alstra peptide synthesizers
A fully automated single-channel microwave peptide synthesizer for scales from 5 µmol to 2 mmol. Reactor vials of 5, 10 and 30 mL, 40–100 °C, 0–120 W and three digital syringe pumps with a 10 mL sample loop. Branches software handles cyclic and branched peptides.
- Scale: 5 µmol to 2 mmol
- Vials: 5, 10 and 30 mL
- Heating: 40–100 °C
- Weight 42 kg
TurboVap evaporators
Nitrogen blowdown evaporation with vortex shearing, four configurations on one platform: LV for 24 or 48 samples, II for 6 tubes with end-point detection, EH for Extrahera racks and P+ for 48 samples. The TurboVap 96 Dual heats gas up to 65 °C and the plate up to 80 °C.
- LV, II, EH, P+ nitrogen: 4–9 bar
- TurboVap LV: 24 or 48 samples
- II end point: 0.5 or 1.0 mL
- 96 Dual: up to 90 L/min per manifold
Biotage V-10 Touch evaporator
Evaporation of aqueous and organic solvents, including NMP and DMF, with sample rotation at 3000–8000 rpm. Heating 20–70 °C, a 5 mbar internal vacuum pump and a −25 °C refrigerated condenser. With an external pump on the KF-16 flange, solvents boiling up to 205 °C can be removed.
- Rotation: 3000–8000 rpm
- Heating: 20–70 °C
- Condenser: −25 °C
- Weight 50 kg
Extrahera sample preparation workstations
Automated solid-phase extraction under 0–5 bar positive pressure. The LV-200 has an 8-channel head for 96-well plates, the HV-5000 four channels of 250–5000 µL and up to 48 samples in parallel, and the Classic handles plates and cartridges. Five automatic and five manual solvent reservoirs.
- Pressure: 0–5 bar, 0.1 bar steps
- HV-5000: up to 48 samples
- LV-200 and HV-5000: 80 kg
- Classic: 75 kg
Choosing a flash system by flow and scale
The Selekt Enkel serves routine purification in drug discovery labs: 1–150 mL/min, 0–15 bar and columns up to 120 g. The Selekt runs at 1–300 mL/min and 0–30 bar, takes Sfär columns from 5 to 340 g and up to 1.85 kg with a safety valve, and has two column lines.
The Isolera One offers 1–200 mL/min and 10 bar for 1–5 purifications per day, and the Isolera LS 50–500 mL/min and up to 150 g of sample per run.
The Flash 400L and Flash 400M are skid-mounted systems for kilogram scale: a recommended flow of 2–5 L/min, radial column compression at 80–100 psig, a pneumatic pump up to 6.9 bar, inert gas drive and a weight of about 455 kg.
Microwave synthesis: Initiator+ and Alstra
The Initiator+ handles organic synthesis at 40–300 °C and up to 30 bar, with reaction volumes of 0.2–20 mL, a 0–400 W magnetron and the Robot Eight or Robot Sixty for 8 or 60 vials.
The Initiator+ Alstra synthesizes peptides from 5 µmol to 2 mmol at 40–100 °C with 5, 10 and 30 mL reactor vials, three syringe pumps and a weight of 42 kg.
Sample preparation and evaporation
The Extrahera LV-200 handles low volumes in 96-well plates, the HV-5000 takes 3–15 mL cartridges and up to 48 samples, and the Classic works with plates and cartridges, all at 0–5 bar. The Horizon 5000 runs disk extraction of 40–2000 mL water samples, up to 12 at a time.
The PrepXpert-8 runs two methods at once with six solvents.
Evaporators: the TurboVap LV for 24 or 48 samples, the TurboVap II for 6 tubes with end-point detection, the TurboVap 96 Dual for 96, 48 or 24 well plates, and the V-10 Touch for vials at 3000–8000 rpm.
Biotage and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Biotage and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for BÜCHI Labortechnik
- Equipment and parts for Agilent Technologies
- Equipment and parts for Shimadzu
- Equipment and parts for CellaVision
Documents and sources
- Company history — since 1969
- Contacts — Uppsala headquarters
- Spare parts list — system part numbers
- Selekt flash system — specifications
- Selekt Enkel flash system — specifications
- Isolera One flash system — specifications
- Isolera LS flash system — specifications
- Flash 400 production system — specifications
- Initiator+ microwave synthesizer — specifications
- Initiator+ Alstra peptide synthesizer — specifications
- TurboVap evaporators — specifications
- TurboVap 96 Dual evaporator — specifications
- V-10 Touch evaporator — specifications
- Extrahera LV-200 workstation — specifications
- Extrahera HV-5000 workstation — specifications
- Extrahera Classic workstation — specifications
- Horizon 5000 disk extraction — specifications
- PrepXpert-8 system — specifications