CPS Instruments disc centrifuges
Selection of CPS Instruments disc centrifuges for particle size analysis: DC12000, DC18000 and DC24000UHR models, the gradient builder, autosampler, low density disc and calibration standards.
DC12000, DC18000, DC24000UHR centrifuges
CPS disc centrifuges separate particles by size via centrifugal sedimentation in a liquid with a density gradient. Models differ in maximum speed: DC12000 runs at 12,000 rpm, DC18000 at 18,000 rpm and DC24000UHR at 24,000 rpm; DC24000UHR also measures smaller particles.
- DC12000: up to 12,000 rpm
- DC18000: up to 18,000 rpm
- DC24000UHR: up to 24,000 rpm
- Typical run of 3 to 15 minutes
Speed ramp inserts
Disc inserts let the speed change during a measurement without mixing the liquid. Speed rises from below 1,800 rpm to 24,000 rpm (24,000 is the DC24000UHR limit). Maker example: polystyrene of 20 to 0.075 microns takes about 19 hours at fixed speed and about 30 minutes with ramping.
- Ramp from below 1,800 rpm
- Size ratio of 1,000 or more
- Runs up to 100 times shorter
- Speed Ramp Insert parts
Low density disc
Particles lighter than the fluid were hard to measure by sedimentation. In the CPS low density disc the sample is deposited at the bottom of the spinning chamber, not the fluid surface, and the particles move toward the centre of rotation. The design is covered by US Patent 5,786,898.
- Sample fed at chamber bottom
- Particles move to the centre
- US Patent 5,786,898
- Polybutadiene standards
Automatic gradient builder
The builder fills the disc with a density gradient and removes manual filling errors. The operator selects the total volume and starts the fill cycle; the gradient forms in under a minute. It works with water and many non-aqueous gradients; tubing kits and sucrose are made for it.
- Gradient in under a minute
- Water and non-aqueous fluids
- Autogradient tubing kit
- Sucrose for solutions
Autosampler for 20 samples
The autosampler carousel hooks onto the front of the centrifuge and holds up to 20 samples and calibration standards. The software makes injections during unattended operation, with no manual start for each run. Injection uses the Dispensing Needles from the CPS accessory list.
- Up to 20 samples and standards
- Unattended injections
- Mounts on the front panel
- Dispensing needles
Control and analysis software
The standard CPS software is fully graphical with point-and-click commands. It reports weight, surface, number and absorption distributions on log or linear scaling. Centrifuge speed is set on screen, and all data files export as comma separated values for custom analysis methods.
- Weight and number distributions
- Log or linear scaling
- On-screen speed control
- CSV data export
Particle size standards
Every analysis on a CPS disc centrifuge is run against a known calibration standard. CPS standards are verified by direct physical means, and the stated average size is within 2 percent. The range covers PVC in water, dry PVC and polybutadiene for low density particles.
- Stated average size within 2%
- PVC standards in water
- Dry PVC standards
- Low density polybutadiene
Centrifuge replacement parts
For upkeep of the centrifuge CPS makes replacement parts and accessories: disc closures and the disc closure tool, the air filter, speed ramp inserts, dispensing needles and autogradient tubing. We match them to the centrifuge model and the configuration of the unit.
- Disc closures
- Disc closure tool
- Centrifuge air filter
- Needles and gradient tubing
Choosing CPS centrifuges
CPS Instruments, Inc. is a US company that has made disc centrifuges for particle size analysis since 1992, headquartered in Prairieville, Louisiana.
CPS and its distributors provide trial sample measurements, on-site installation, training and ongoing technical support; the company also offers particle size analysis services.
The line has three models with different maximum speeds: DC12000 (up to 12,000 rpm), DC18000 (up to 18,000 rpm) and DC24000UHR (up to 24,000 rpm). DC24000UHR reaches smaller particles than the other two models. Most samples take 3 to 15 minutes.
Particle size range
The upper size limit for nearly all samples is about 50 microns; the lower limit depends on particle density: gold sols (19 g/mL) down to about 3 nm, ceria (7.2 g/mL) to about 8 nm, polystyrene (1.052 g/mL) to about 35 nm. Narrow peaks that differ by 2% are fully separated.
At fixed speed the largest practical size ratio in one analysis is about 70.
Speed ramp inserts raise the speed during a measurement from below 1,800 rpm to 24,000 rpm (24,000 rpm is the DC24000UHR limit); the ratio then reaches 1,000 or more, and runs of very broad samples become up to 100 times shorter.
Accessories and standards
The automatic gradient builder forms a density gradient in under a minute, for water and many non-aqueous fluids. The autosampler on the front of the centrifuge holds up to 20 samples and standards and injects them unattended.
The low density disc, covered by US Patent 5,786,898, takes the sample at the bottom of the chamber.
Every analysis is run against a calibration standard: CPS makes PVC standards in water, dry PVC standards and polybutadiene standards for low density particles. Replacement parts include disc closures, the air filter, speed ramp inserts, dispensing needles and autogradient tubing.
CPS Instruments and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of CPS Instruments and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Wyatt Technology
- Equipment and parts for Particle Measuring Systems
- Equipment and parts for SOTAX
- Equipment and parts for Biolin Scientific
Documents and sources
- About CPS — founding and headquarters
- CPS disc centrifuge — models and specs
- Industry applications — materials
- Why CPS — standards and sample analysis
- Learning center — technical notes
- Disc closure — replacement part
- Disc closure tool — accessory
- Air filter — replacement part
- Speed ramp insert — accessory
- Dispensing needles — consumable
- Autogradient tubing — kit
- Sucrose for gradients — consumable
- PVC standards in water — particle size
- Dry PVC standards — particle size
- Polybutadiene standards — low density