Particle Measuring Systems particle counters
Selection of PMS instruments: Lasair, AirNet II and IsoAir Pro airborne counters, Ultra DI, HSLIS and LiQuilaz II liquid counters, the HPGP gas counter and MiniCapt air samplers.
Lasair Pro portable counter
Portable aerosol particle counter for cleanrooms, built in three flow rates: 25, 50 and 100 LPM. It connects via Ethernet, Wi-Fi, Modbus, serial or analog outputs and keeps an audit trail of up to 30,000 entries. With the HPD III diffuser it checks compressed air, argon, CO2 and nitrogen.
- Flow 25, 50 or 100 LPM
- Audit trail up to 30,000 entries
- Ethernet, Wi-Fi, Modbus links
- Gases via HPD III diffuser
Lasair III 110 0.1 µm counter
Laser particle counter with 0.1 µm detection for high-grade cleanrooms and filter testing. It comes as a mobile or inline model with pulse output as standard. With the HPD-II diffuser it measures pressurised inert gas. The earlier Lasair III is no longer sold, service for it remains.
- 0.1 µm particle detection
- Mobile or inline model
- Pulse output as standard
- Lasair III: serviced, not sold
AirNet II remote sensors
Remote particle counters for continuous monitoring. The 2-channel models count 0.5 and 5.0 µm at 1.0 CFM, the 4-channel models cover 0.2 to 10.0 µm depending on the model at 0.1 or 1.0 CFM. They connect via Ethernet and Modbus TCP/IP and take distributed power, a local plug or PoE.
- 2-channel: 0.5 and 5.0 µm
- 4-channel: 0.2 to 10.0 µm
- 4-channel: 0.1 or 1.0 CFM
- Ethernet, Modbus TCP/IP
IsoAir Pro remote counter
Particle counter for monitoring systems with an integrated HEPA-filtered blower, so no external vacuum is needed. Range 0.3 to 25.0 µm, 316L stainless steel enclosure with IP65 and NEMA 4X ratings. IsoAir Pro-E runs on PoE. The earlier IsoAir 310P was made obsolete at the end of 2022.
- Range 0.3 to 25.0 µm
- 316L steel enclosure, IP65
- Built-in HEPA blower
- Pro-E: PoE power
Ultra DI and Chem 20 counters
Particle counters for ultrapure water and chemicals. Ultra DI 20 Plus detects particles down to 20 nm, Ultra DI 50 covers a broader range. Chem 20 counts down to 20 nm in chemicals, Chem 20 SM serves hazardous area solvents (IPA, PGMEA). UltraChem 40 became obsolete in 2025.
- Ultra DI 20 Plus: down to 20 nm
- Ultra DI 50: broader range
- Chem 20: 20 nm in chemicals
- Chem 20 SM: IPA, PGMEA solvents
HSLIS water and chemical counters
The HSLIS series monitors DI water and process chemicals, including hydrogen fluoride, down to 0.05 µm in DI water and 0.065 µm in chemicals. Models: M50E for 0.05 to 0.2 µm, M65E for 0.065 to 0.2 µm, M100E for 0.1 to 1.0 µm. Outputs: Ethernet, 4-20 mA and RS-232 diagnostics.
- M50E: 0.05 to 0.2 µm
- M65E: 0.065 to 0.2 µm
- M100E: 0.1 to 1.0 µm
- Ethernet, 4-20 mA, RS-232
LiQuilaz II and APSS-2000
LiQuilaz II uses volumetric sampling: the E series covers 1.5 to 125 µm for pharma water and parenteral samples, the S series 0.2 to 20 µm for chemicals, DI water and photoresists. Up to 15 size channels. APSS-2000 combines a syringe sampler, LiQuilaz E and SamplerSight Pharma software.
- E series: 1.5 to 125 µm
- S series: 0.2 to 20 µm
- Up to 15 size channels
- APSS-2000: volumes within 0.4 mL
MiniCapt and BioCapt samplers
Active air samplers for microbial monitoring. MiniCapt Pro-E 25 runs at 25 LPM on PoE, Pro-Plus 25 and Pro-Plus 100 at 25 and 100 LPM on AC 85-264 VAC or DC 24 VDC. MiniCapt Mobile is portable and takes the CG kit for compressed gas. BioCapt impactors come for 25-50 and 100 L/min.
- Pro-E 25: 25 LPM flow
- Pro-Plus 100: 100 LPM flow
- AC 85-264 VAC or DC 24 VDC
- BioCapt 25 L/min: 4 hours
Choosing PMS instruments
Particle Measuring Systems (PMS) is a US maker of contamination monitoring instruments for clean manufacturing and is part of Spectris plc. Its headquarters and a manufacturing facility are in Niwot, Colorado, with a second manufacturing facility in Zhuhai, China.
The company has worked on laser particle counting since 1972, has a team of 700 employees and local sales and service teams in over 50 countries.
The line-up covers the Lasair, AirNet II, IsoAir Pro, HandiLaz Mini II and NanoAir 10 airborne particle counters, the Ultra DI, Chem 20, HSLIS and LiQuilaz II liquid particle counters, the HPGP 101-C gas particle counter, MiniCapt air samplers with BioCapt impactors, the AirSentry II molecular contamination monitor and the FacilityPro monitoring system.
Airborne particle counters
For portable work there is Lasair Pro at 25, 50 or 100 LPM and Lasair III 110 with 0.1 µm detection as a mobile or inline model; the handheld HandiLaz Mini II counts 0.2 to 10 µm.
For continuous monitoring there are AirNet II sensors (2-channel: 0.5 and 5.0 µm; 4-channel: 0.2 to 10.0 µm) and IsoAir Pro with an integrated blower (0.3 to 25.0 µm).
For semiconductor tools there is the NanoAir 10 condensation particle counter for 10 nm: 12 months of maintenance-free monitoring and the 10-port ParticleSeeker manifold. Lasair III and IsoAir 310P are obsolete and were succeeded by Lasair Pro and IsoAir Pro.
Liquids, gases and microbial air
Ultrapure water is monitored by Ultra DI 20 Plus (down to 20 nm) and Ultra DI 50, chemicals by Chem 20 (down to 20 nm) and Chem 20 SM for hazardous area solvents. The HSLIS series: M50E for 0.05 to 0.2 µm, M65E for 0.065 to 0.2 µm, M100E for 0.1 to 1.0 µm.
LiQuilaz II comes as the E series (1.5 to 125 µm) and S series (0.2 to 20 µm) with up to 15 channels; APSS-2000 is built on LiQuilaz E.
In-line gas at up to 150 psig is measured by HPGP 101-C (0.1 to 5.0 µm), and HPD diffusers prepare compressed gases for standard counters. MiniCapt Pro samplers run at 25 and 100 LPM, BioCapt impactors at 25-50 and 100 L/min.
AirSentry II detects acids and bases with a lower detection limit of 70 ppt.
Particle Measuring Systems and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Particle Measuring Systems and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Wyatt Technology
- Equipment and parts for Alicat Scientific
- Equipment and parts for Specim
- Equipment and parts for ADVACAM
Documents and sources
- About PMS — part of Spectris
- Offices — Niwot headquarters
- Parent company Spectris — divisions
- PMS service — repair and calibration
- Lasair Pro counter — overview
- Lasair III 110 counter — overview
- Lasair III counter — no longer sold
- AirNet II sensors — models
- IsoAir Pro counter — overview
- IsoAir 310P sensor — obsolete
- Ultra DI counters — models
- Chem 20 counters — models
- UltraChem 40 counter — obsolete
- HSLIS counters — models
- LiQuilaz II counters — series
- APSS-2000 system — components
- MiniCapt Pro sampler — models
- MiniCapt Mobile sampler — overview
- BioCapt impactors — flow rates
- Compressed gas kit — pressure
- HPGP 101-C gas counter — overview
- HPD high pressure diffusers — overview
- AirSentry II monitor — overview
- NanoAir 10 counter — overview
- HandiLaz Mini II handheld — overview
- FacilityPro monitoring system — versions