Alicat Scientific mass flow and pressure controllers

Technical selection of Alicat Scientific instruments (Tucson, Arizona, USA, part of Halma): gas mass flow controllers and meters, CODA Coriolis instruments, liquid flow meters, pressure controllers and FusionFlow gas mixers.

MC mass flow controllers for gas

MC controllers use laminar differential pressure: 0.5 SCCM to 12,000 SLPM full scale, 11.5-160 PSIA, control response as fast as 30 ms, 10,000:1 control range. Accuracy is as good as ±0.5% of reading or ±0.1% of full scale. MCS is corrosion resistant, MCQ runs to 320 PSIA, MCD is bidirectional.

  • Flow 0.5 SCCM to 12,000 SLPM
  • Control response from 30 ms
  • 10,000:1 control range
  • MCQ pressure up to 320 PSIA

M, MQ, MS and BIO gas flow meters

M meters use laminar differential pressure and measure mass flow, volumetric flow, temperature and pressure: 0.5 SCCM to 12,000 SLPM at 11.5-160 PSIA, a 10,000:1 range and accuracy as good as ±0.5% of reading. MQ runs at 11.5-320 PSIA, MS handles 130 gases, BIO serves bioreactors.

  • Flow 0.5 SCCM to 12,000 SLPM
  • 10,000:1 measurement range
  • Accuracy as good as ±0.5%
  • MS: 130 gases

Whisper low pressure drop controllers

Whisper MCW suits systems with limited source pressure: pressure drop as low as 0.07 PSID, 0.5 SCCM to 1,000 SLPM, 60 PSIA maximum. Accuracy is as good as ±0.6% of reading or ±0.1% of full scale, 200:1 control range, 30 ms response. MCDW holds pressure in a closed volume for leak checking.

  • Pressure drop from 0.07 PSID
  • Flow up to 1,000 SLPM
  • Pressure up to 60 PSIA
  • 200:1 control range

MCV and SFF vacuum controllers

MCV and SFF are preconfigured for vacuum processes such as CVD, ALD, PVD and coating: 0.5 SCCM to 20 SLPM, 10,000:1 range, accuracy as good as ±0.5% of reading or ±0.1% of full scale. MCV has an integrated pneumatic shutoff valve; SFF has a SEMI footprint and replaces the MCE series.

  • Flow 0.5 SCCM to 20 SLPM
  • CVD, ALD and PVD processes
  • MCV pneumatic shutoff valve
  • SFF SEMI footprint

CODA Coriolis instruments

CODA Coriolis instruments measure mass flow, density and temperature of gases and liquids, even of unknown composition, from 40 g/h to 300 kg/h. In high accuracy versions the KC gas controller reaches ±0.5% of reading with 50:1, the K liquid meter ±0.2% with 500:1. KG pump systems cover 1-100 kg/h.

  • Flow 40 g/h to 300 kg/h
  • KC for gas: ±0.5% of reading
  • K for liquids: ±0.2%
  • KG pump system: 1-100 kg/h

L and LC liquid flow instruments

L and LC instruments use laminar differential pressure for water or 9 other pure liquids. The LC controller covers 0.5 CCM to 10 LPM, up to 100 PSIG, ±2% of full scale accuracy, a 0.01-100% control range and 30 ms response. LCS handles corrosive liquids, LB is a battery powered portable meter.

  • LC flow 0.5 CCM to 10 LPM
  • LC pressure up to 100 PSIG
  • LC accuracy ±2% of full scale
  • LC control response 30 ms

PC and PCD pressure controllers

PC controllers hold absolute, gauge or differential pressure from 0.07 to 3,000 PSI with ±0.125% of full scale accuracy and ±0.08% repeatability; vacuum options are ±0.5%. PC3 measures pressure at one point and controls it at another. Dual valve PCD units serve closed volumes.

  • PC ranges 0.07 to 3,000 PSI
  • PC accuracy ±0.125% of full scale
  • Repeatability ±0.08%
  • Dual valve PCD

IS-Max controllers for hazardous areas

IS-Max ISMC controllers are intrinsically safe for Class I Div 1 and Zone 0 with no purge gas or explosion-proof housing: 0.5 SCCM to 250 SLPM, 11.5-160 PSIA, up to 320 PSIA for ISMCQ, IP66 enclosure. ISMCS carries 128 gas calibrations. For Class I Div 2, MC controllers come with the -X option.

  • Class I Div 1 and Zone 0
  • Flow 0.5 SCCM to 250 SLPM
  • IP66 enclosure
  • ISMCS: 128 gas calibrations

Choosing a gas mass flow controller

The core range is MC controllers and M meters with laminar differential pressure sensing: 0.5 SCCM to 12,000 SLPM with a 10,000:1 range.

Where source pressure is low, Whisper MCW drops as little as 0.07 PSID; vacuum processes such as CVD, ALD and PVD use MCV and SFF; gases of unknown composition go to CODA KC Coriolis controllers for 40 g/h to 300 kg/h.

For OEM equipment, compact BASIS controllers with a MEMS thermal sensor cover 100 SCCM to 100 SLPM at 0-145 PSIG with accuracy as good as 1.5% of reading or 0.2% of full scale. MB portable meters serve as transfer standards for flow verification.

FusionFlow gas mixers

FusionFlow IMX blends up to 4 gas streams at combined flow rates from 0-20 to 0-3200 SLPM, with mix accuracy as good as ±0.6% of the targeted percentage. FusionFlow MXM handles up to 10 streams and up to 120,000 SLPM in total; both mixers use Alicat mass flow controllers on every channel.

Pressure controllers and liquid instruments

PC pressure controllers serve flowing processes in ranges from 0.07 to 3,000 PSI with ±0.125% of full scale accuracy, dual valve PCD units serve closed or dead-ended volumes, and PC3 controls pressure at one point from a sensor at another.

For liquid flow, choose L meters and LC controllers for water or 9 other pure liquids (LC covers 0.5 CCM to 10 LPM), or CODA K for liquids and slurries.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.