Beckman / Beckman Coulter (Beckman Coulter Life Sciences) Instruments & Spare Parts
Analytical and bioprocessing instruments by Beckman / Beckman Coulter / Beckman Coulter Life Sciences: Optima, Avanti and Allegra centrifuges, CytoFLEX and Navios flow cytometers, Biomek and Echo liquid handlers, particle counters and PAT700 TOC.
Optima XPN, XE, MAX & AUC Ultracentrifuges
Floor-standing Optima XPN and XE reach 100,000 rpm and 802,000 x g up to 1,500 mL. Benchtop Optima MAX-XP delivers 150,000 rpm and 1,019,000 x g for viral vectors and exosomes. Beckman Coulter service parts cover vacuum seals, drive assemblies, imbalance sensors, and control boards.
- Optima XPN / XE: up to 100,000 rpm, 802,000 x g, 1,500 mL
- Optima MAX-XP: up to 150,000 rpm, 1,019,000 x g, 194.4 mL
- Optima MAX-TL / Airfuge: 110,000-120,000 rpm compact units
- Spares: vacuum pumps, shaft seals, drives, optical AUC detectors
Avanti High-Speed & Allegra Benchtop Centrifuges
Avanti JXN-30 and JXN-26 deliver 26,000-30,000 rpm and up to 110,510 x g across 4-6 L capacity. Compact Allegra 64R, V-15R, X-30, and Microfuge units support routine pelleting and cell harvesting. Replaceable hardware includes brushless drives, lid latches, cooling loops, and rotor ID sensors.
- Avanti JXN-30 / JXN-26: 26,000-30,000 rpm, up to 110,510 x g
- Avanti J-HC: 9.0 L bioprocessing capacity, 10,000 rpm
- Allegra 64R / V-15R / C-34R: 13,500-30,000 rpm benchtop models
- Spares: brushless motors, lid locks, refrigeration valves, PCBs
Centrifuge Rotors, BioSafety Buckets & Adapters
Beckman Coulter rotors include fixed-angle, swinging-bucket, vertical, near-vertical, continuous-flow, 3 L zonal, AUC, and 2-50 um elutriation types. BioSafety canisters contain aerosols during runs. Replacement kits cover O-rings, trunnion pins, adapters, and OptiMate tools.
- Geometry: fixed-angle, swinging-bucket, vertical, zonal (3 L)
- Elutriation & AUC: 2-50 um cell separation and optical rotors
- Containment: BioSafety sealed canisters and transparent covers
- Spares: O-ring kits, bucket lids, adapters, tube racks, vises
CytoFLEX, Navios EX Flow Cytometers & Cell Sorters
Research CytoFLEX platforms scale from 1 laser and 4 channels to 3 lasers and 13 channels (CytoFLEX), 4 lasers (CytoFLEX S), and 6 lasers (CytoFLEX LX), with 13 interchangeable bandpass filters. Clinical Navios EX tracks 12 parameters, while CytoFLEX SRT adapts MoFlo sorting to 15 channels.
- CytoFLEX / S / LX: 3 to 6 lasers, interchangeable bandpass filters
- Navios EX: 3 solid-state lasers, 12 parameters, integrated optics
- CytoFLEX SRT / MoFlo lineage: 4 lasers, 15 channels, 4-way sort
- Spares: laser modules, flow cells, sheath pumps, capsule filters
Biomek i-Series & Echo Acoustic Liquid Handlers
Biomek i3, i5, and i7 systems offer 20, 25, or 45 deck positions for 0.5-5,000 uL pipetting. Echo 650 Plus and Echo 525 acoustic dispensers transfer droplets down to 2.5 nL and 25 nL without tips at up to 700 droplets per second using ADE and Dynamic Fluid Analysis.
- Biomek i3 / i5 / i7: 20, 25, or 45 deck positions, 0.5-5,000 uL
- Biomek NGeniuS & Access: integrated NGS and robotic workcells
- Echo 650 Plus / 525: 2.5 nL and 25 nL tip-less ADE transfer
- Spares: pipetting pods, grippers, ALP stations, transducers, valves
Multisizer, LS 13 320 XR, HIAC, MET ONE & PAT700 TOC
Multisizer 4e measures 0.2-1,600 um via Coulter apertures, while LS 13 320 XR covers 10 nm-3,500 um by laser diffraction and PIDS. MET ONE air counters, HIAC 9703+ liquid counters, and PAT700 online TOC analyzers comply with ISO 21501-4, USP 643/645, and EP 2.2.44.
- Multisizer 4e: Coulter Principle 0.2-1,600 um, 10,000 counts/s
- LS 13 320 XR: 10 nm-3,500 um with 450/600/900 nm PIDS optics
- MET ONE & HIAC 9703+: 0.3-10.0 um airborne and 1-1,000 mL liquid
- PAT700 / Anatel TOC: PW/WFI/CIP online UV lamps, flow cells, valves
Selecting Beckman / Beckman Coulter / Beckman Coulter Life Sciences Systems by Application
Beckman / Beckman Coulter / Beckman Coulter Life Sciences (USA, Danaher Life Sciences) covers centrifugation (Optima ultracentrifuges, Avanti high-speed, Allegra and Microfuge benchtop), flow cytometry and cell sorting (CytoFLEX, Navios EX, CytoFLEX SRT with MoFlo heritage), automated liquid handling (Biomek i-Series and Echo acoustic dispensers), particle counting and sizing (Multisizer 4e, LS 13 320 XR, HIAC 9703+, MET ONE), and online TOC analysis (PAT700 / Anatel).
Configuration depends on target RCF and rotor volume, laser excitation lines and bandpass filters, deck capacity, particle size detection limits (10 nm to 3,500 um), and pharmacopeial or cleanroom standards.
Rotors, Consumables & System Integration for Biopharma and Research
Centrifuge systems pair with fixed-angle, swinging-bucket, vertical, near-vertical, continuous-flow, 3 L zonal, AUC, and elutriation rotors plus BioSafety containment accessories.
Flow cytometers and Biomek i5/i7 workstations integrate with 96-well plate loaders, Access robotic cells, and Echo 525/650 Plus acoustic transfer units.
Cleanroom and pharmaceutical QC facilities deploy MET ONE portable/remote counters, HIAC 9703+ liquid counters, and PAT700 TOC/conductivity analyzers engineered for USP 643/645, EP 2.2.44, ISO 14644, and 21 CFR Part 11 data integrity.
Beckman / Beckman Coulter and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Beckman / Beckman Coulter and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Infors HT
- Equipment and parts for Biolin Scientific
- Equipment and parts for Biotage
- Equipment and parts for Boule Diagnostics
- Equipment and parts for CellaVision
Documents and sources
- Beckman Coulter Life Sciences — Company profile and Danaher heritage
- Beckman Coulter — Optima XPN, XE, MAX-XP, MAX-TL & Airfuge Ultracentrifuges
- Beckman Coulter — Avanti High-Speed Centrifuges (JXN-30, JXN-26, J-HC)
- Beckman Coulter — Allegra & Microfuge Benchtop Centrifuges
- Beckman Coulter — Centrifuge Rotors (Fixed-Angle, Swinging-Bucket, Zonal, AUC)
- Beckman Coulter — CytoFLEX Research Flow Cytometer Configurations
- Beckman Coulter — Navios EX Clinical Flow Cytometer
- Beckman Coulter — CytoFLEX SRT Cell Sorter
- Beckman Coulter — Biomek i-Series Automated Liquid Handlers
- Beckman Coulter — Echo Acoustic Liquid Handlers
- Beckman Coulter — Multisizer 4e Coulter Counter Particle Analyzer
- Beckman Coulter — LS 13 320 XR Laser Diffraction Particle Size Analyzer
- Beckman Coulter — PAT700 Total Organic Carbon (TOC) Analyzer
- Beckman Coulter — MET ONE Airborne Particle Counters
- Beckman Coulter — HIAC 9703+ Liquid Particle Counter
- Beckman Coulter — Instrument Qualification (IQ/OQ) and Calibration