CellaVision digital morphology analyzers and RAL stainers
Technical selection of CellaVision equipment (Lund, Sweden): DM9600, DM1200 and DC-1 digital cell morphology analyzers, RAL Stainer 2, RAL Stainer and RAL StainBox stainers and RAL staining kits.
CellaVision DM9600 analyzers
Analyzer for high-volume hematology labs, launched in 2014. Eight magazines of 12 slides with continuous feed and up to 30 slides per hour for a complete differential. Immersion oil is dispensed automatically from a replaceable oil pack.
- Loading: 96 slides
- Up to 30 slides/h
- Size 580×560×790 mm
- Weight 93 kg
CellaVision DM1200 analyzers
Analyzer for large and medium-sized labs, launched in 2009. One magazine of 12 slides, up to 20 slides per hour for a complete differential and up to 15 slides per hour for body fluid smears. Oil is dispensed automatically; barcode labeled slides are required.
- Loading: 12 slides
- Up to 20 slides/h
- Size 576×450×710 mm
- Weight 80 kg
CellaVision DC-1 analyzer
Compact analyzer for low-volume labs, launched in 2019. Slides are loaded one at a time, up to 10 slides per hour for a complete differential, with a built-in smear check. Oil is applied manually; the analyzer runs on 12 VDC from an external power supply.
- Loading: one slide
- Up to 10 slides/h
- 12 VDC, 7 A input
- Weight 11 kg
RAL Stainer 2 automated stainer
Automated bath stainer for peripheral blood and bone marrow slides. Two magazines of 10 slides, about 30-40 slides per hour and dual-axis agitation. Baths are filled, drained and cleaned automatically, and an active carbon cartridge filters vapors.
- Loading: 20 slides
- About 30-40 slides/h
- Active carbon cartridge
- Weight 25.7 kg
RAL Stainer automated stainer
Closed automated stainer for 30-200 slides per day: up to 10 slides per cycle, 4 staining stations and 1 rinsing station. Protocols load from the RFID tag of each RAL Diagnostics kit, and an activated carbon filter cleans the chamber air.
- Up to 10 slides/cycle
- 4 staining + 1 rinsing station
- 2×10 L containers
- Weight 28 kg
RAL StainBox semi-automated stainer
Semi-automated stainer for low-volume labs using the bath method with step-by-step guidance. 5 slides per cycle, about 20 slides per hour and ready-to-use methanol-free staining kits. Together with the DC-1 it forms the DIFF-Line set.
- 5 slides per cycle
- About 20 slides/h
- 12 V via power adapter
- Weight 3.988 kg
RAL staining kits
CellaVision makes its reagents in-house in Martillac, France; RAL Diagnostics joined the group in 2019. Kits for the stainers include RAL Stainer MCDh (ref. 360200), RAL StainBox MCDh (ref. 360300) and RAL Stainer 555 (ref. 360250); the catalogue also lists RAL immersion oil.
- Stainer MCDh kit: ref. 360200
- StainBox MCDh kit: ref. 360300
- Stainer 555 kit: ref. 360250
- RAL immersion oil
DM and DC-1 analyzer accessories
For the DM9600 the manufacturer lists the CellaVision Immersion Oil Pack, barcode labeled slide magazines, QC barcode labels and a label printer kit. For the DC-1: immersion oil, QC barcode labels, a label printer kit and a hand-held barcode reader.
- Immersion oil pack
- Slide magazines
- QC barcode labels
- Hand-held barcode reader
Choosing an analyzer by slide volume
The DC-1 is designed for low-volume hematology labs: one slide at a time and up to 10 slides per hour for a complete differential. The DM1200 suits large and medium-sized labs with a 12-slide magazine and up to 20 slides per hour.
The DM9600 is built for high volume: 96 slides with continuous feed and up to 30 slides per hour. Since 2021 small labs can use the DIFF-Line set of the DC-1 analyzer and the RAL StainBox semi-automated stainer.
DM analyzers process blood and body fluid smears and require barcode labeled slides; the DC-1 processes blood smears, and the slide ID is entered manually or with a hand-held reader.
Choosing a RAL stainer
RAL StainBox is a semi-automated stainer for 5 slides per cycle and about 20 slides per hour. RAL Stainer is a closed automated unit for 30-200 slides per day and up to 10 slides per cycle; it runs only RAL Diagnostics kits, and the protocol loads from the kit RFID tag.
RAL Stainer 2 holds 20 slides in two magazines, stains about 30-40 slides per hour, handles peripheral blood and bone marrow slides and works with May-Grünwald Giemsa and MCDh Zero stains.
Software and analyzer networks
CellaVision Server Software keeps one database for one or several sites: up to 70 analyzers and 75 remote reviewers (200 GB), with support for the DM1200, DM9600, DC-1 and Review Software. The analyzers talk to the LIS over ASTM through Ethernet 10/100 Mbps.
CellaVision and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of CellaVision and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Agilent Cell Analysis
- Equipment and parts for Olympus
- Equipment and parts for Bioquell
Documents and sources
- Company history — since 1994
- About the company — production and range
- DM9600 analyzer — specifications
- DM1200 analyzer — specifications
- DC-1 analyzer — specifications
- DIFF-Line set — scope
- RAL StainBox — specifications
- RAL Stainer — specifications
- RAL Stainer 2 — specifications
- Reagent catalogue — kits and oil
- Server Software — capabilities