Hardy Process Solutions weight controllers and load cells
Technical selection of Hardy Process Solutions (formerly Hardy Instruments) equipment: HI6850 controllers, HI 6500 and HI 6200 processors, the HI6600 system, HI 1756-WS and HI5069 modules for Rockwell PLCs, HISBHC14, HI STLB and HISP4 load cells.
HI6850 weight controller
HI6850 is a dual-core weight controller with up to 4 weight channels. The main scale input card updates at 250 Hz and three optional scale cards at 100 Hz, with stable resolution of 1:30,000. It has dual-port Ethernet with an embedded switch, the HI6150 7-inch touchscreen and an 8-relay card.
- Up to 4 weight channels
- Resolution 1:30,000
- Main scale card: 250 Hz
- Relay card with 8 outputs
HI 6500 and HI 6500-XP weight processors
HI 6500 units are EtherNet/IP weight processors that also offer Modbus, Ethernet and analog options. HI 6500 and HI 6510 deliver 1:10,000 resolution at 110 updates per second, while HI 6500-XP reaches 660 updates per second at 1:30,000. A stainless NEMA 4X wall enclosure has an IP66 display panel.
- HI 6500: resolution 1:10,000
- HI 6500: 110 updates per second
- HI 6500-XP: 660 updates per second
- Enclosure display panel: IP66
HI 6200 single-channel processors and transmitters
The HI 6200 series covers single-channel weight processors with EtherNet/IP or PROFINET and weight transmitters with 4-20 mA output. Processors deliver 100 updates per second at resolution above 1:10,000, the analog version 50. It mounts on a DIN rail and replaces analog strain gage transmitters.
- 4-20 mA output or PROFINET
- Processor: 100 updates per second
- Analog version: 50 per second
- Up to 8 load cells at 350 ohm
HI6600 modular system with up to 30 channels
HI6600 is a modular weight processor system that sends up to 30 weight channels to a PLC over one fieldbus connection. Each channel takes signals from up to four load cells and updates 110 times per second. Modules connect to the gateway with Cat5e cable; uses include tank farms and fillers.
- Up to 30 weight channels
- Up to 4 load cells per channel
- 110 updates per second
- Cat5e link to the gateway
HI 1756-WS modules for ControlLogix
The single-channel HI 1756-WS and dual-channel HI 1756-2WS mount in an Allen-Bradley ControlLogix chassis and pass weight data over the backplane. Each scale drives up to four 350 ohm load cells at 5 V, internal resolution is 1:8,388,608; Series C updates 100 times per second, Series A and B 50.
- HI 1756-WS and 2WS modules
- Up to 4 load cells at 350 ohm
- Series C: 100 updates per second
- Operating range 0 to 60 °C
HI5069 and HI5034-WS modules for Rockwell
HI5069-WS and HI5069-2WS plug onto the backplane of CompactLogix 5380 controllers and deliver filtered weight 250 times per second, using a 24-bit sigma-delta ADC, device authentication and firmware encryption. HI5034-WS for PointMax I/O adaptors delivers 125 updates per second.
- HI5069: 250 updates per second
- 24-bit sigma-delta ADC
- HI5034-WS: 125 updates per second
- Up to 8 load cells per channel
Shear beam load cells and OneMount load points
The HISBHC14 stainless steel, fully hermetic shear beam load cell comes in 500, 1000, 2500 and 5000 lbs with IP68/IP69K protection, ±0.02 % combined error and 5-15 V excitation. OneMount HIONELP load points cover 1,125 to 22,500 lbs; spacers carry full capacity before the load cell is fitted.
- HISBHC14: 500 to 5000 lbs
- HISBHC14 protection IP68/IP69K
- Combined error ±0.02 %
- OneMount: up to 22,500 lbs
S-beam and single point load cells
The HI STLB S-type sensor in 17-4PH stainless steel with IP67 rating works in tension and compression under hanging vessels, hoppers and filling machinery, from 100 kg to 5000 kg. The HISP4 single point load cell for 20, 50 and 100 kg is rated Class III and has threaded holes for multi-head fillers.
- HI STLB: 100 to 5000 kg
- HI STLB protection IP67
- HISP4: 20, 50 and 100 kg
- HISP4 accuracy Class III
Choosing a Hardy weighing instrument
For multi-channel weighing with process control, the HI6850 controller offers up to 4 weight channels, 1:30,000 resolution and an embedded Ethernet switch.
Where weight only has to be measured and passed to the control system, HI 6500 processors (1:10,000, 110 updates per second) or the fast HI 6500-XP with 660 updates per second are used.
The single-channel HI 6200 replaces analog strain gage transmitters as a processor with EtherNet/IP or PROFINET or a transmitter with 4-20 mA output. Tank farms and multi-head fillers use the HI6600 modular system with up to 30 weight channels.
Weigh modules for Rockwell PLCs and feeder control
Hardy modules install directly in Rockwell Automation PLCs: HI 1756-WS and HI 1756-2WS in a ControlLogix chassis, HI5069-WS on the CompactLogix 5380 backplane and HI5034-WS in PointMax I/O adaptors. Weight reaches the controller over the backplane without a separate weighing instrument.
For feeder control, the HI 1769-FC module for CompactLogix and MicroLogix 1500 drives auger, belt and vibratory feeders, updates 100 times per second and runs a five-point automatic rate calibration.
Load cells and load points for vessels
Vessels and hoppers on supports use HISBHC14 shear beam load cells for 500 to 5000 lbs and OneMount HIONELP load points for 1,125 to 22,500 lbs. In OneMount load points, matched mV/V/ohm load cells are replaced without recalibration.
Hanging vessels use HI STLB S-type sensors for 100 to 5000 kg, while fillers and platform scales use HISP4 single point load cells for 20, 50 and 100 kg. Load cells with C2 allow calibration without test weights.
Hardy Process Solutions and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Hardy Process Solutions and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for HBM
- Equipment and parts for Kistler
- Equipment and parts for JADEVER
- Equipment and parts for Veeder-Root
Documents and sources
- Home page — weighing solutions
- Our story — company history since 1918
- Contact us — San Diego headquarters
- HI6850 weight controller — specifications
- HI 6500 weight processors — specifications
- HI 6200 weight processors — specifications
- HI6600 modular sensor system — modules and channels
- HI 1756-WS ControlLogix modules — specifications
- HI5069 Compact 5000 modules — specifications
- HI5034-WS PointMax module — specifications
- HI 1769-FC feeder controller — functions
- HISBHC14 shear beam load cell — specifications
- OneMount HIONELP load points — specifications
- HI STLB tension load cell — capacities
- HISP4 single point load cell — specifications
- WAVERSAVER vibration eliminator — settings
- C2 weightless calibration — verification
- Calibration and preventive maintenance — methods
- Installation and startup — checklist
- Hardy repair program — load cell evaluation