Agilent CrossLab Chromatography Columns and Laboratory Consumables

Supply of chromatography columns, sample preparation products, and laboratory consumables by Agilent CrossLab: Poroshell 120, ZORBAX columns, J&W capillaries, Bond Elut SPE cartridges, vials, and hollow cathode lamps.

Agilent InfinityLab Poroshell 120 HPLC and UHPLC Columns

Analytical chromatography columns featuring superficially porous particles with a solid silica core and porous outer layer. Delivers exceptional separation resolution at half the system backpressure, accelerating complex gradient methods across standard liquid chromatographs.

  • Superficially porous microparticles engineered in 1.9, 2.7, and 4 um diameters
  • Broad portfolio of reversed-phase chemistries including EC-C18, EC-C8, and Phenyl-Hexyl
  • Full pressure compatibility with high-throughput liquid systems up to 600 and 1300 bar
  • Dedicated Aq-C18 and HILIC phases optimized for polar metabolite retention

Agilent ZORBAX Reversed-Phase Analytical HPLC Columns

Industry-standard chromatography columns packed with ultrapure ZORBAX Rx-SIL porous silica for routine analysis of pharmaceuticals, chemical precursors, and biomolecules. Offers reproducible selectivity paired with extended chemical stability across broad pH mobile phases.

  • ZORBAX Eclipse Plus packings delivering symmetrical peaks for basic compounds
  • Non-endcapped StableBond SB-C18 phases offering stability in low-pH mobile phases
  • Bidentate-bonded Extend-C18 columns providing durability across pH 2.0 to 11.5
  • Wide-pore 300SB packings engineered for polypeptide, protein, and macromolecule recovery

Agilent J&W Capillary Gas Chromatography Columns

Fused silica capillary columns protected with polyimide coatings and chemically bonded stationary phases across DB and HP series. Delivers ultra-low column bleed for sensitive mass spectrometry detection alongside stable retention timing in gas analysis workflows.

  • Non-polar and mid-polarity DB-1, DB-5ms, and HP-5ms phases for routine screening
  • Polyethylene glycol DB-WAX and VF-WAXms columns for alcohol and solvent testing
  • High-temperature DB-HT metal and silica columns operating up to 400 degrees
  • Porous polymer PoraPLOT tubing separating permanent gases and volatile hydrocarbons

Agilent Bond Elut Solid Phase Extraction Cartridges and Plates

Engineered SPE extraction sorbents and pre-packed barrels designed to selectively isolate target analytes while eliminating matrix interferences. Extensively deployed across clinical toxicology, wastewater monitoring, and pharmacokinetic screening of complex biological fluids.

  • Polymeric monodisperse Bond Elut Plexa sorbent minimizing endogenous protein binding
  • Silica-based reversed phase chemistries including C18, C8, Diol, and Aminopropyl
  • Ion exchange sorbents SAX, SCX, PRS, and CBA for selective ionic compound recovery
  • High-density 96-well extraction microplates compatible with automated workstations

Agilent QuEChERS Sample Preparation Kits and Captiva Filters

Rapid sample clean-up solutions tailored for food matrices, agricultural products, and biological extracts. QuEChERS extraction packets and Captiva syringe filters efficiently eliminate lipids, pigments, and microparticles, safeguarding chromatography columns from fouling.

  • Pre-weighed QuEChERS extraction salts and dispersive SPE sorbents matching EN and AOAC
  • Captiva Premium syringe filters with chemical-resistant PTFE, Nylon, PVDF, and PES membranes
  • Captiva EMR-Lipid filtration tubes removing hydrophobic fats without analyte loss
  • Low-extractable filter membranes tested for minimal ultraviolet and MS background noise

Agilent Autosampler Vials, Caps, Septa, and Precision Syringes

Engineered glass and polymer 2 mL sample vials, microvolume inserts, and automated autosampler syringes for chromatography injectors. Guarantees leak-tight sample preservation for volatile solvents while preventing needle coring and bent plunge errors during high-speed runs.

  • Borosilicate glass vials fabricated from Class 1 Type A and Type B hydrolytic glass
  • Screw and crimp closure caps featuring bonded pre-slit PTFE and silicone septa
  • Deactivated A-Line surface-treated vials preventing adsorption of trace basic compounds
  • Gold Brand and Blue Line precision syringes offering zero dead volume needle travel

Agilent Spectroscopy Hollow Cathode Lamps, Torches, and Nebulizers

Optical and plasma consumables engineered for atomic absorption and inductively coupled plasma instrumentation. Ensures stable spectral emission lines, reproducible sample aerosolization, and uninterrupted detector operation across aggressive acid and brine sample streams.

  • Single-element and multi-element hollow cathode lamps HCL designed for AA spectrometers
  • One-piece and demountable quartz ICP torches fitted with alumina or quartz injectors
  • Scott double-pass spray chambers and cyclonic mist chambers with fluoropolymer fittings
  • Color-coded peristaltic pump tubing with calibrated internal bore geometry

Agilent InfinityLab Quick Connect Fittings, Capillaries, and Standards

Fluidic interconnection hardware for liquid and gas chromatography manifolds, delivering zero dead volume seals without thread damage risks. Prevents chromatographic band broadening while safeguarding baseline stability and retention time precision throughout laboratory analytical batches.

  • Finger-tight Quick Connect and Quick Turn spring-loaded fittings requiring no wrenches
  • Stainless steel and inert PEEK capillary tubing with square precision-cut ends
  • Solvent inlet reservoir filter frits and inline degassing micro-membranes for pumps
  • Traceable chemical calibration standards for instrument qualification and tuning

Conditioning and equilibration protocols for Poroshell 120 columns

Preparing analytical Agilent InfinityLab Poroshell 120 chromatography columns requires preliminary flushing and thermal equilibration before initiating gradient runs.

Flush newly installed columns with a mobile phase blend of HPLC-grade acetonitrile and deionized water at reduced volumetric flow to gently equilibrate porous packing resistance.

When transitioning from buffered salt eluents to high-organic solvent compositions, insert an intermediate wash step with pure water to prevent inorganic salt precipitation inside particle pores.

Monitoring system backpressure stability alongside optical absorbance confirms complete capillary equilibration before running high-throughput sample sequences.

Regeneration procedures and solvent storage for ZORBAX reversed-phase packings

Extended operation of Agilent ZORBAX Eclipse Plus and StableBond columns with biological matrices leads to hydrophobic contaminant accumulation at the inlet frit.

Restoring chromatographic efficiency involves multi-step regeneration using solvents of increasing elution strength: isopropanol blended with methanol, followed by pure acetonitrile flushes.

Perform regeneration in reversed flow orientation without connecting columns to sensitive mass spectrometry or optical detectors. Store porous silica columns exclusively in organic solvents containing at least eighty percent acetonitrile to inhibit microbial growth inside the stationary phase bed.

Installation and thermal conditioning of Agilent J&W capillary GC columns

Installing fused silica Agilent J&W capillary columns across DB and HP series into gas chromatography injectors and detectors requires square precision cuts using a ceramic scoring wafer. Jagged silica edges distort carrier gas flow dynamics and cause peak broadening for volatile hydrocarbons.

Column insertion depth must be verified against manufacturer inlet scales. After tightening capillary fittings, purge the gas flow line with high-purity helium or hydrogen for thirty minutes to eliminate ambient oxygen.

Perform temperature conditioning by ramping oven heat slowly toward maximum phase limits with detectors disconnected.

Optimizing solid phase extraction workflows on Bond Elut sorbent beds

Developing extraction methods on Agilent Bond Elut SPE cartridges begins by selecting appropriate conditioning solvents to solvate bonded functional ligands.

Polymeric Bond Elut Plexa sorbents withstand bed drying without losing analyte recovery, whereas traditional silica C18 sorbents require continuous wetting prior to sample loading.

Regulate vacuum manifold aspiration rates between one and two milliliters per minute to ensure kinetic binding equilibrium. Stepwise washing steps eliminate endogenous polar salts and proteins, producing concentrated sample extracts ready for downstream liquid chromatography.

QuEChERS extraction protocols and Captiva membrane filtration techniques

Analyzing pesticide residues in food matrices using pre-packaged QuEChERS salt packets accelerates multiresidue sample clean-up workflows. Phase partitioning between aqueous homogenates and acetonitrile is driven by magnesium sulfate and sodium chloride addition paired with centrifugation.

Dispersive clean-up tubes containing primary secondary amine PSA and graphitized carbon black GCB remove organic acids and chlorophyll.

Filter final extract supernatants through chemically inert Captiva syringe filters equipped with 0.2 um PTFE or PVDF membranes to prevent particulate clogs in autosampler loops.

Preventing evaporation and analyte adsorption across autosampler vials and septa

Preserving volatile organic compounds during chromatography batch sequences relies on reliable sample vial sealing integrity. Utilizing pre-slit PTFE and silicone septa reduces autosampler needle penetration resistance while preventing rubber coring debris from contaminating injection valves.

For trace protein and peptide samples, Agilent A-Line deactivated glass vials eliminate polar analyte adsorption onto active silanol sites on glass interior walls.

Tighten screw caps to uniform compression stops to form airtight seals without wrinkling elastomeric septum layers during prolonged automated runs.

Maintenance guidelines for ICP torches, spray chambers, and hollow cathode lamps

Maintaining spectral emission intensity during elemental analysis on ICP-OES and AA instruments requires routine optical and plasma component upkeep. Quartz torches undergo ultrasonic cleaning in diluted nitric and hydrochloric acid baths to dissolve accumulated salt deposits and matrix residues.

Injector tips and alumina tubes should be examined for thermal micro-cracking. Hollow cathode lamps HCL must be installed according to polarity and warmed up at operating current for fifteen minutes until cathode discharge stabilizes.

Optimize optical alignment to achieve maximum baseline transmission.

Installing InfinityLab Quick Connect fittings and preserving fluidic pathway hygiene

Deploying Agilent InfinityLab Quick Connect and Quick Turn fittings enables finger-tight HPLC capillary installations without requiring mechanical wrenches.

The spring-loaded internal plunger automatically presses capillary tubing flush against column and valve connection seats, eliminating dead volume and preventing peak tailing.

Routine replacement of solvent reservoir filter frits paired with ultrasonic cleaning of pump degassing units prevents dissolved gas bubbles and baseline pressure oscillations, ensuring reproducible retention times throughout gradient chromatography.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

Nastia — scan this QR code to add her on WeChat

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

QR code to open Telegram: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.