Agilent Cell Analysis and BioTek Laboratory Instrumentation
Integrated solutions for live-cell biology and microplate automation by Agilent Cell Analysis and BioTek: Seahorse metabolic flux analyzers, multimode imaging readers, automated washers, and cytometers.
Agilent Seahorse XF Pro and XFe96 Extracellular Flux Analyzers
Specialized analytical workstations engineered for real-time kinetic measurement of cellular respiration and glycolysis. Systems quantify oxygen consumption rate OCR alongside extracellular acidification rate ECAR across standard 96-well microplates with high reproducibility.
- Solid-state sensor cartridges with optical fluorophores detecting oxygen and proton flux
- Four automated pneumatic drug injection ports per well for programmable compound delivery
- Precision isothermal chamber maintaining uniform thermal equilibrium for cell cultures
- Standardized kinetic protocols for mitochondrial stress testing and glycolytic rate profiling
BioTek Cytation 5 and Cytation 7 Cell Imaging Multimode Readers
Automated digital microscopy workstations combining automated imaging optics with multimode microplate detection. Features automated brightfield, phase contrast, and multichannel fluorescence detection paired with variable monochromator optics for comprehensive phenotypic screening.
- Motorized objective turret accommodating 1.25x to 60x magnifications with autofocus
- Dual imaging engine featuring both inverted and upright microscope optical configurations
- Hybrid optical architecture merging Quad monochromators with sensitive bandpass filter cubes
- Environmental gas controller regulating carbon dioxide and oxygen for kinetic live-cell assays
BioTek Synergy Neo2 and Synergy H1 Hybrid Multimode Microplate Readers
High-throughput multi-mode microplate readers designed for demanding biochemical screening and cellular assays from 6 to 1536-well density. Incorporates independent optical pathways utilizing variable Quad monochromators alongside high-transmission filter modules for ultra-sensitive readout.
- Dedicated photomultiplier tubes delivering high sensitivity for HTRF, TR-FRET, and FP modes
- Interchangeable optical filter cubes and high-powered AlphaScreen laser excitation source
- Programmable linear and orbital shaking with uniform incubation temperature up to 65 °C
- Dual automated reagent syringe injectors facilitating rapid flash luminescence kinetic assays
BioTek LogPhase 600 Microbiology Readers and Epoch 2 Spectrophotometers
Purpose-built absorbance microplate readers engineered for continuous microbial growth curve monitoring at OD600. Instruments deliver simultaneous automated acquisition across four 96-well microplates with robust continuous shaking mechanisms preventing microbial sedimentation.
- Parallel automated capacity accommodating up to four standard 96-well plates simultaneously
- High-energy orbital shaking mechanism maintaining homogeneous microbial suspension in wells
- Integrated Condensation Control thermal gradient preventing droplet formation on plate lids
- Monochromator optical selection spanning UV-Vis wavelengths from 200 nm to 999 nm on Epoch 2
BioTek 405 TS and 50 TS Automated Microplate Washers
Industry-benchmark automated washing systems optimized for 96-well and 384-well microplate protocols across ELISA, magnetic bead assays, and adherent cell cultures. Equipped with built-in Ultrasonic Advantage technology preventing manifold needle clogging from crystallized salts.
- Integrated ultrasonic water bath automatically clearing manifold dispensing and aspiration pins
- Specialized Cell Wash gentle fluidic control minimizing detachment of delicate monolayer cells
- Intuitive touchscreen interface programming multi-point bottom aspiration for low residual volumes
- Dual-Action wash manifolds supporting independent buffer routing without cross-contamination
BioTek MultiFlo FX Multimode Dispensers and BioSpa 8 Incubators
Versatile automated liquid handling workstations handling dispensing and washing across 6- to 1536-well plate geometries. MultiFlo FX modular architecture accommodates up to four independent dispensing technologies combining peristaltic tubing heads and high-precision syringe drives.
- Parallel combination of low dead-volume peristaltic pumps and precision syringe dispensers
- Random Access Dispensing RAD technology enabling single-well custom volume liquid addition
- Autoclavable dispensing tubing cartridges maintaining sterile conditions for cell growth media
- Full hardware synchronization with BioSpa 8 automated incubators and BioStack plate stackers
Agilent xCELLigence Real-Time Cell Analysis (RTCA) Systems
Label-free cell analysis platforms utilizing high-density microelectronic biosensor arrays to monitor cellular phenotypic dynamics. Real-time electrical impedance measurements quantify cell adhesion, proliferation rate, barrier function, and cytotoxicity kinetics without perturbation.
- Specialized E-Plate consumables with integrated gold microelectrodes across well bottoms
- Label-free non-invasive continuous acquisition preserving authentic cell biology in tests
- RTCA DP analyzer architecture featuring three independent 16-well cradles inside incubators
- Dual-chamber CIM-Plate consumables quantifying kinetic cell migration and invasion assays
Agilent NovoCyte and NovoCyte Quanteon High-Performance Flow Cytometers
High-performance benchtop flow cytometers engineered for complex multiparameter cellular analysis and immunophenotyping. Equipped with up to four spatially separated solid-state lasers and up to 25 fluorescence detection channels covering a wide dynamic range across diverse cell assays.
- Direct volumetric fluidic sampling delivering precise absolute cell counts without beads
- Silicon photomultiplier sensors providing high sensitivity with over 7-decade dynamic range
- Automated NovoSampler Q accommodating tube racks alongside 96- and 384-well microplate trays
- Automated fluidic decontamination and rinsing cycles virtually eliminating sample carryover
Calibration and hydration protocols for Seahorse XF sensor cartridges
Determining cellular oxygen consumption rate OCR and extracellular acidification rate ECAR across Agilent Seahorse XF Pro and XFe96 analyzers requires proper hydration of solid-state sensor cartridges.
Optical fluorophore sensors must be submerged in Seahorse XF Calibrant liquid inside a non-CO2 incubator at thirty-seven degrees for at least eight hours prior to analytical runs.
Loading drug delivery ports with metabolic modulators including Oligomycin, FCCP, and Rotenone demands precision pipetting without touching delicate well walls. Verifying pneumatic manifold seals ensures consistent delivery pressure without fluidic leakage across kinetic runs.
Optical alignment and objective lens upkeep on BioTek Cytation workstations
Automated digital microscopy systems BioTek Cytation 5 and Cytation 7 integrate sensitive optics with high-precision microplate positioning stages.
Preserving imaging resolution across 1.25x to 60x microscope objectives requires routine wiping of front lens elements using spectroscopic-grade alcohol and optical tissue.
Accumulation of culture media vapors on fluorescence filter cubes increases background noise and distorts multi-color image analysis.
Calibrating motorized laser autofocus mechanisms against dedicated validation plates maintains reliable optical focal tracking across long kinetic live-cell experiments.
Optical pathway alignment and monochromator care for Synergy Neo2 readers
Multimode microplate readers BioTek Synergy Neo2 and H1 utilize variable Quad monochromator networks alongside optical bandpass filters for HTRF and TR-FRET assays. Ensuring excitation energy throughput requires periodic inspection of optical mirror alignment and fiber optic light guides.
During high-density screening from 96- to 1536-well microplates, detector compartments remain isolated from chemical vapors. Routine dark current baseline checks against reference verification plates validate photomultiplier linearity across UV and visible wavelengths.
Temperature gradient regulation and condensation control on LogPhase 600
Microbial absorbance readers BioTek LogPhase 600 and Epoch 2 spectrophotometers monitor continuous optical density kinetics of bacterial and fungal suspensions at OD600.
Condensation Control technology maintains an engineered vertical thermal gradient, preventing moisture droplet accumulation on microplate lids during multi-day incubations. Continuous orbital shaking across four standard microplates requires periodic inspection of drive suspension dampers.
Wiping optical lenses free from dust particles prevents false absorbance fluctuations.
Manifold maintenance and ultrasonic decontamination for BioTek 405 TS washers
Operating microplate washers across 405 TS and 50 TS series during ELISA assays involves salt crystallization hazards within fine aspiration and dispensing pins.
Integrated Ultrasonic Advantage cleaning reservoirs require daily deionized water replenishment and regular ultrasonic clearing cycles following operational shifts.
Disassembling Dual-Action manifolds for biochemical residue removal includes thorough inspection of elastomeric O-rings and internal fluid channels. Routine rinsing of vacuum traps and overflow float switches prevents moisture ingress into dry vacuum pump modules.
Peristaltic module calibration and pump upkeep on MultiFlo FX dispensers
BioTek MultiFlo FX multimode dispensers utilize precision peristaltic tubing heads and syringe drives for non-contact micro-dispensing into microplates up to 1536-well density.
To preserve volumetric accuracy, elastomeric pump tubing requires periodic gravimetric volume verification and pump coefficient adjustments. Autoclaving fluidic modules in disassembled configurations protects tubing elasticity against thermal micro-cracking.
Wiping RAD dispensing pins removes protein deposits and avoids droplet deflection during low-volume liquid transfers into individual wells.
Microelectrode biosensor verification on xCELLigence RTCA workstations
Label-free impedance analysis across Agilent xCELLigence RTCA DP and RTCA eSight systems depends on the electrical integrity of gold biosensors in E-Plate consumables.
Prior to experimental setup, recording baseline electrical impedance across buffer-filled wells verifies spring-loaded gold contact pins on incubation station cradles.
Ribbon interconnect cables routing signals between the incubator pod and the external analyzer controller must remain free from sharp bends or thermal stress. Wiping station contact pins with isopropyl alcohol prevents high-resistance contact artifacts.
Fluidic system decontamination and laser alignment on NovoCyte flow cytometers
Detection sensitivity and volumetric precision across Agilent NovoCyte and NovoCyte Quanteon flow cytometers require laminar hydrodynamic flow within the quartz flow cell.
Routine fluidic decontamination using NovoClean reagent followed by deionized NovoRinse flushes prevents fluorochrome dye carryover and cell debris build-up in sample intake needles. Monitoring sheath fluid reservoir pressure ensures uninterrupted hydrodynamic focusing during acquisition batches.
Periodic calibration with fluorescent alignment beads confirms stable detector amplification factors and spectral separation.
Agilent Cell Analysis and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Agilent Cell Analysis and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Agilent Technologies
- Equipment and parts for Agilent Spectroscopy
- Equipment and parts for Agilent Vacuum Technologies
- Equipment and parts for Edwards Vacuum
Documents and sources
- Seahorse XF Pro Extracellular Flux Analyzer — Official Product Data Sheet and Kinetic Specifications (PDF)
- BioTek Cytation 5 Cell Imaging Reader — Product Brochure for Automated Microscopy and Detection (PDF)
- BioTek Synergy Neo2 Hybrid Reader — Technical Brochure for High-Throughput Screening (PDF)
- BioTek LogPhase 600 Microbiology Reader — Product Brochure for Microbial Growth Kinetics (PDF)
- BioTek 405 TS Microplate Washer — Technical Data Sheet for Automated Washing Systems (PDF)
- BioTek MultiFlo FX Multimode Dispenser — Product Data Sheet for Automated Liquid Handling (PDF)
- xCELLigence RTCA DP Impedance Analyzer — Product Brochure for Real-Time Cell Monitoring (PDF)
- Agilent NovoCyte Flow Cytometer — Product Brochure for Multiparameter Cell Analysis (PDF)