SUSA Technology (Susa Electronics) Gas Sensors & Micro Pumps

4-Series & 7-Series electrochemical sensors (4CO-SF, 4CO, 4H2S-AS, 4O2-GS), 4PID VOC sensors with in-house VUV lamps, catalytic elements, and oil-free 138 pumps.

4CO-SF, 4CO, 4CO-AF — Electrochemical CO Sensors

SUSA 4CO-SF and 4CO 3-electrode electrochemical sensors measure 0-2000 ppm CO with 75±15 nA/ppm positive sensitivity. The 4CO-AF variant covers 0-100 ppm at 200±50 nA/ppm. Built in the standard 4-Series layout, they serve portable and fixed industrial safety monitors.

  • 4CO-SF & 4CO: 0-2000 ppm CO range, 75±15 nA/ppm positive signal
  • 4CO-AF: 0-100 ppm CO range, 200±50 nA/ppm positive sensitivity
  • 3-electrode (W/C/R) 4-Series architecture with linear response
  • Recommended CO span check: 200-400 ppm gas at 100-300 ml/min

4H2S-AS, 4NO2-CT, 4SO2-NT — Toxic Gas Cells

SUSA 4H2S-AS (0-100 ppm), 4NO2-CT (0-20 ppm), and 4SO2-NT (0-1000 ppm) cells monitor toxic hazards in petrochemical and metallurgical plants. The 4-Series and higher-resolution 7-Series also cover Cl2 (CL2-DS, CL2-LS) and NO-HS. Low power draw simplifies detector integration.

  • 4H2S-AS: 0-100 ppm H2S, 800±200 nA/ppm positive sensitivity
  • 4NO2-CT: 0-20 ppm NO2, 600±150 nA/ppm negative output signal
  • 4SO2-NT: 0-1000 ppm SO2, 50±10 nA/ppm positive sensitivity
  • 7-Series cells deliver higher resolution for chemical plants

NH3-AR, 4NH3-SR, 4SiH4-LS, 4HCHO-DM, 4THT-LT

Specialty cells target ammonia NH3-AR (0-100 ppm) and 4NH3-SR (0-500 ppm), silane 4SiH4-LS (0-50 ppm), unbiased formaldehyde 4HCHO-DM (0-10 ppm), and gas odorant 4THT-LT (0-50 mg/m3). Additional models include PH3-CS, HCN-LS, and HF-DS for industrial safety.

  • NH3-AR (0-100 ppm, 150±50 nA/ppm) & 4NH3-SR (0-500 ppm, 50±20 nA/ppm)
  • 4SiH4-LS silane: 0-50 ppm range, 130±50 nA/ppm sensitivity
  • 4HCHO-DM formaldehyde: zero bias, 0-10 ppm, 550±150 nA/ppm
  • 4THT-LT odorant: 0-50 mg/m3 range, 140±50 nA/(mg/m3)

4O2-GS Oxygen & Biased Electrochemical Cells

The 4O2-GS oxygen sensor measures 0-25% O2 (30% O2 overload), outputs 100±20 uA in air with a 10 s response, and runs at -600 mV bias. SUSA 3-electrode geometry also supports +200/+300 mV positive bias for low-activity gases such as ETO-AS, HCL-LS, and NO-HS.

  • 4O2-GS: 0-25% O2 (30% overload), 100±20 uA in air, 10 s response
  • 4O2-GS operates with -600 mV bias; 0 mV cells ship shorted
  • +200/+300 mV bias enables oxidation on ETO-AS, HCL-LS, and NO-HS
  • Biased cells require at least 24 hours stabilization after power-up

4PID Series — Photoionization VOC Sensors

SUSA 4PID photoionization sensors combine a self-developed vacuum UV lamp, low-noise circuit, and micro ionization chamber for VOC detection from 5 ppb up to 10,000 ppm. Models span 4PID-20 to 4PID-10000 (3.2-5 V, 1.8-3 V output) plus 3.3V-plus variants.

  • 4PID-20 to 4PID-10000: 3.2-5 V supply, 1.8-3 V output, 5 ppb limit
  • /3.3V-plus series: 3.3±0.1 V supply, 2.0±0.5 V signal output
  • Sensitivity from >75 mV/ppm (20 ppm) to >0.15 mV/ppm (10,000 ppm)
  • Compact 4-Series layout with Ex ia intrinsically safe design

Vacuum UV PID Lamps & Ionization Chambers

SUSA Technology independently designs and manufactures multiple specifications of vacuum ultraviolet (PID) lamps. Low ignition voltage and reduced operating current extend battery runtime and lamp longevity across handheld and fixed VOC gas analyzers.

  • In-house VUV PID lamp engineering and manufacturing since 2009
  • Low starting voltage and low working current for portable instruments
  • Serviceable micro ionization chambers and detection boards for 4PID
  • Selective to VOCs, arsine, and NH3 without N2/O2/CO2/CH4 interference

4RCAT3, Cat23CH, NAP25 — Catalytic LEL Sensors

SUSA catalytic sensors include 4RCAT3 (0-100% LEL, >15 mV/%CH4), acetylene detector element Cat23CH (0-2.5% C2H2, <10 s response), and methane beads NAP25, MJC42.8LN-090, MJC42.9±0.2J(B), Cat2.5VN-180, and Cat2.7VNM-200 with high poison and shock resistance.

  • 4RCAT3: 0-100% LEL combustible gases, >15 mV/%CH4 sensitivity
  • Cat23CH acetylene element: 0-2.5% C2H2, >=12 mV/1% C2H2, <10 s
  • MJC42.8LN-090 (0-5% CH4, >20 mV/1% CH4) & NAP25 (>=12 mV/1% CH4)
  • Cat2.5VN-180, Cat2.7VNM-200, and MJC42.9±0.2J(B) for gas alarms

138 Micro Suction Pumps & Smart Sensor Modules

Oil-free micro suction pumps (3.0V 138-000-030, 3.3V, 3.6V 138-600-100, 4.25V 138-000-043, 3.3V Pr 138-331-000, 3.6V TPr 138-602-100) deliver 40-42 kPa vacuum and 10,000+ hour life. Smart modules (3.5-5.5 V DC, 0.4-2.5 V output) add plug-and-play EMI immunity.

  • 3.3V Pr (138-331-000, >500 ml/min) & 3.6V TPr (138-602-100, >400 ml/min)
  • 4.25V (138-000-043, 500±100 ml/min) & 3.0V (138-000-030, 450±100 ml/min)
  • Oil-free, <25-30 mA draw, 40-42±5 kPa vacuum, >=10,000 h continuous run
  • Smart modules: 3.5-5.5 V DC supply, 0.4-2.5 V output, RF/EMI shielding

SUSA Technology Gas Sensor Portfolio (Shanghai, Est. 2009)

Shanghai Susa Electronics Technology Co., Ltd. (SUSA Technology) develops and manufactures 4-Series, 7-Series, and miniature electrochemical gas cells, 4PID photoionization sensors powered by in-house vacuum UV lamps, catalytic LEL elements, smart modules, and oil-free micro suction pumps.

Electrochemical models cover CO (4CO-SF, 4CO, 4CO-AF), H2S, NO2, SO2, O2, NH3, SiH4, HCHO, and THT, while 7-Series cells add higher resolution for chemical and environmental analyzers. Catalytic elements include 4RCAT3 (0-100% LEL) and acetylene element Cat23CH.

Electrical Interfaces, Bias Aging, and Socket Mounting

Zero-bias 3-electrode cells ship shorted and need no aging, whereas biased cells (+200/+300 mV for ETO-AS, HCL-LS, NO-HS and -600 mV for 4O2-GS) must stabilize under power for at least 24 hours.

Match 4PID supply rails carefully between standard 3.2-5 V (1.8-3 V out) and 3.3±0.1 V (/3.3V-plus, 2.0±0.5 V out).

Smart sensor modules operate from 3.5-5.5 V DC with a 0.4-2.5 V analog signal and high RF/EMI immunity. All pin-type cells must plug into PCB sockets; direct soldering onto sensor pins is prohibited due to electrolyte leakage risk.

Span Calibration, Gas Line Materials, and Protection

SUSA recommends calibration every 12 months with zeroing in clean air or N2. Use 100-300 ml/min flow for CO (200-400 ppm), 200-400 ml/min for H2S/NO2/SO2/NO/ETO, and >=500 ml/min for strongly adsorbing Cl2, NH3, HCl, HCN, and HF.

Construct sample lines and filter gaskets for reactive gases using PTFE or 316 stainless steel rather than polyurethane or bare steel mesh, keep the hydrophobic PTFE membrane intact, and prevent exposure to silicones, oils, adhesives, and organic solvent vapors.

SUSA Technology and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of SUSA Technology and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.