Modular chillers LUC, LSF fan coils, LMV VRF systems, VENT air handling units, LUR rooftops, close-control cabinets, LUQ condensing units, and LZ-CG hydronic skids configured to project specs.

LUC Air-Cooled Chillers

Series C modular air-cooled scroll chillers cover 33 to 260 kW and link up to 16 modules for 4160 kW total capacity. The range adds Series X inverter chillers down to -10 °C, LUC-E(I)HA(D)A...CAW to 82 kW, and free-cooling units. Scroll compressors, EEVs, and flow switches are sourced.

  • 33–260 kW per module, up to 16 units (4160 kW)
  • Economizer +6% capacity, EER up to 7.1
  • Free-cooling and Series X inverter operation to -10 °C
  • Daikin / Danfoss scroll compressors, shell-and-tube evaporator

LSF Fan Coil Units & Piping Kits

LSF hydronic terminals cover wall KH22, cassette BM22 / BM42 / BP22C, floor-ceiling AQ22, and 30 / 50 Pa ducted DG42 / DD22H(E) units. Both 2-pipe and 4-pipe water circuits serve hotels and commercial halls. Fan motors, PCBs, LZ-V valves, and thermostats are matched.

  • 2-pipe and 4-pipe water coils, 30 Pa and 50 Pa static
  • Cassette LSF-BM42, B1J22, BP22C, BE42C series
  • Ducted LSF-DG42 / DD22H(E) / DR22(E) and Slice units
  • LZ-V2 / LZ-V4 3-way actuators and piping valve kits

LMV Multi-Zone VRF Systems

LMV VRF lines cover NEO (Mini C 8–17.5 kW, Citadel V6 20–90 kW, Alliance V6 to 270 kW, Submarine, Heat Recover V6) and EVO (12–101 kW). Full-inverter compressors and fans allow up to 130% indoor load. Inverter boards, EEVs, sensors, and LZ-UPW controllers are available.

  • NEO up to 270 kW modular and EVO 12–101 kW lines
  • 2-pipe heat pump and 3-pipe heat recovery systems
  • Full DC-inverter drive, up to 130% diversity ratio
  • Inverter boards, EEV coils, and LZ-UPW / LZ-HJPW controls

VENT Air Handling & ERV Units

Central VENT AHUs span industrial, hygienic (F5–F9, H10–H14, UV stage), arctic (-60 °C without plastics), rooftop, and pool dehumidifier builds. Compact units integrate rotary or membrane heat recovery up to 85% and EC fans. Replacement EC motors, coils, filters, and actuators are sourced.

  • Central AHUs: industrial, hygienic, arctic down to -60 °C
  • Compact ERVs with up to 85% heat recovery
  • Filtration stages G4 / F5–F9 / H10–H14 and UV modules
  • EC motor fans, water/electric coils, GTC control panels

LUR Packaged Rooftop Units

Packaged rooftops LUR-WF22...450 (cooling) and LUR-WFR22...450 (heat pump) serve warehouses, retail halls, and bays. Galvanized anti-corrosion housings integrate scroll compressors and factory refrigerant charge. Replacement compressors, blower motors, TXVs, pressure switches, and PCBs are supplied.

  • LUR-WF (cooling) and LUR-WFR (heat/cool) 22–450 range
  • Factory-charged refrigeration circuit with scroll compressors
  • Galvanized anti-corrosion outdoor housing
  • Replacement blower motors, belts, pressure controls, PCBs

LSP / LUE Close-Control Units

Precision cabinets span 5.5–20 kW (GMCC rotary inverters, LSP-VCA / LUE-VCP) and 27–120 kW (Hitachi scroll). Built for data centers and labs, they run at -40 to +45 °C with 100 m piping and 30 m lift. EC fans, EEVs, Modbus RS485 controllers, and T/RH sensors are matched.

  • 5.5–20 kW (GMCC rotary) and 27–120 kW (Hitachi scroll)
  • 100 m piping, 30 m vertical lift, -40 to +45 °C ambient
  • EC fans, EEVs, Modbus RS485 and 64-unit group rotation
  • Touch display boards, T/RH sensors, and humidifier parts

LUQ Condensing & LZ-CG Hydronics

LUQ-E...AUA2(4)-H(V) inverter condensing units (10–73 kW, linked to 219 kW) feed AHU coils via LZ-AHU kits. Factory LZ-CG...-O and dual-pump LZ-CG...D-O skids deliver 5.7–292 m³/h at 6 bar with Wilo pumps. Wilo pumps, expansion vessels, probes, and EEV kits are sourced.

  • LUQ-E inverter condensing units 10–73 kW (up to 219 kW)
  • LZ-CG...-O / D-O pump skids: 5.7–292 m³/h, 6 bar max
  • Wilo circulation pumps for water and 50% glycol loops
  • Heated control panels, expansion tanks, and LZ-AHU kits

LZ Controls, Valves & Interfaces

Factory controls cover LZ-AHU155VA2 / 360TA2 / 560TA2 DX interface kits with EEVs and probes, chiller remotes LZ-MIPW / MIPS / MPPW2 / CEPW5, and VRF remotes LZ-UPW4F / UPW6 / UPW7 / HJPW. Piping assemblies use LZ-V2 / V4 valves and ZRU-P kits. Exact spares match by code.

  • LZ-AHU155VA2 / 360TA2 / 560TA2 DX interface modules
  • Chiller controllers LZ-MIPW, LZ-MIPS, LZ-MPPW2, LZ-CEPW5
  • Wired and touch VRF remotes LZ-UPW / LZ-HJPW / LZ-KMP
  • LZ-V2 / LZ-V4 3-way motorized valves and ZRU-P kits

Chiller Plant Architecture & Hydronic Skids

Central chilled-water plants combine Series C modular air-cooled scroll chillers (33–260 kW per module, linking up to 16 units to 4160 kW with economizers and EER up to 7.1), Series X DC-inverter chillers down to -10 °C, and scroll or screw free-cooling chillers.

Hydronic circulation is handled by factory-assembled LZ-CG...-O single-pump and LZ-CG...D-O dual-pump modules equipped with Wilo pumps, expansion tanks, and heated control cabinets for 5.7–292 m³/h flow at 6 bar across water and up to 50% glycol circuits.

VRF Systems LMV & Precision Close Control

LMV multi-zone VRF systems in NEO and EVO series run full-inverter compressors and fans with up to 130% diversity ratio, spanning Mini C (8–17.5 kW), Citadel V6 (20–90 kW), modular Alliance V6 (25.2–270 kW), water-cooled Submarine, and 3-pipe heat recovery units.

Data centers, telecom rooms, and clean laboratories use close-control cabinets from 5.5–20 kW (GMCC rotary inverter) to 27–120 kW (Hitachi scroll inverter) featuring EC fans, EEVs, Modbus RS485 BMS integration, 64-unit group rotation, and -40 to +45 °C operation.

VENT Air Handling, LUR Rooftops & DX Integration

VENT central air handling units cover industrial, hygienic (F5–F9, H10–H14 filters, UV sanitization), arctic (-60 °C without plastic parts), rooftop, and pool dehumidifier builds, while compact ERVs provide up to 85% heat recovery with EC motors and GTC controls.

DX cooling coils in AHUs connect to LUQ-E inverter condensing units (10–73 kW, linked up to 219 kW) via LZ-AHU interface kits, and large single-zone halls use factory-charged LUR-WF / LUR-WFR 22–450 galvanized rooftops.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.