LESSAR Commercial and Industrial HVAC Equipment
Modular chillers LUC, LSF fan coils, LMV VRF systems, VENT air handling units, LUR rooftops, close-control cabinets, LUQ condensing units, and LZ-CG hydronic skids configured to project specs.
LUC Air-Cooled Chillers
Series C modular air-cooled scroll chillers cover 33 to 260 kW and link up to 16 modules for 4160 kW total capacity. The range adds Series X inverter chillers down to -10 °C, LUC-E(I)HA(D)A...CAW to 82 kW, and free-cooling units. Scroll compressors, EEVs, and flow switches are sourced.
- 33–260 kW per module, up to 16 units (4160 kW)
- Economizer +6% capacity, EER up to 7.1
- Free-cooling and Series X inverter operation to -10 °C
- Daikin / Danfoss scroll compressors, shell-and-tube evaporator
LSF Fan Coil Units & Piping Kits
LSF hydronic terminals cover wall KH22, cassette BM22 / BM42 / BP22C, floor-ceiling AQ22, and 30 / 50 Pa ducted DG42 / DD22H(E) units. Both 2-pipe and 4-pipe water circuits serve hotels and commercial halls. Fan motors, PCBs, LZ-V valves, and thermostats are matched.
- 2-pipe and 4-pipe water coils, 30 Pa and 50 Pa static
- Cassette LSF-BM42, B1J22, BP22C, BE42C series
- Ducted LSF-DG42 / DD22H(E) / DR22(E) and Slice units
- LZ-V2 / LZ-V4 3-way actuators and piping valve kits
LMV Multi-Zone VRF Systems
LMV VRF lines cover NEO (Mini C 8–17.5 kW, Citadel V6 20–90 kW, Alliance V6 to 270 kW, Submarine, Heat Recover V6) and EVO (12–101 kW). Full-inverter compressors and fans allow up to 130% indoor load. Inverter boards, EEVs, sensors, and LZ-UPW controllers are available.
- NEO up to 270 kW modular and EVO 12–101 kW lines
- 2-pipe heat pump and 3-pipe heat recovery systems
- Full DC-inverter drive, up to 130% diversity ratio
- Inverter boards, EEV coils, and LZ-UPW / LZ-HJPW controls
VENT Air Handling & ERV Units
Central VENT AHUs span industrial, hygienic (F5–F9, H10–H14, UV stage), arctic (-60 °C without plastics), rooftop, and pool dehumidifier builds. Compact units integrate rotary or membrane heat recovery up to 85% and EC fans. Replacement EC motors, coils, filters, and actuators are sourced.
- Central AHUs: industrial, hygienic, arctic down to -60 °C
- Compact ERVs with up to 85% heat recovery
- Filtration stages G4 / F5–F9 / H10–H14 and UV modules
- EC motor fans, water/electric coils, GTC control panels
LUR Packaged Rooftop Units
Packaged rooftops LUR-WF22...450 (cooling) and LUR-WFR22...450 (heat pump) serve warehouses, retail halls, and bays. Galvanized anti-corrosion housings integrate scroll compressors and factory refrigerant charge. Replacement compressors, blower motors, TXVs, pressure switches, and PCBs are supplied.
- LUR-WF (cooling) and LUR-WFR (heat/cool) 22–450 range
- Factory-charged refrigeration circuit with scroll compressors
- Galvanized anti-corrosion outdoor housing
- Replacement blower motors, belts, pressure controls, PCBs
LSP / LUE Close-Control Units
Precision cabinets span 5.5–20 kW (GMCC rotary inverters, LSP-VCA / LUE-VCP) and 27–120 kW (Hitachi scroll). Built for data centers and labs, they run at -40 to +45 °C with 100 m piping and 30 m lift. EC fans, EEVs, Modbus RS485 controllers, and T/RH sensors are matched.
- 5.5–20 kW (GMCC rotary) and 27–120 kW (Hitachi scroll)
- 100 m piping, 30 m vertical lift, -40 to +45 °C ambient
- EC fans, EEVs, Modbus RS485 and 64-unit group rotation
- Touch display boards, T/RH sensors, and humidifier parts
LUQ Condensing & LZ-CG Hydronics
LUQ-E...AUA2(4)-H(V) inverter condensing units (10–73 kW, linked to 219 kW) feed AHU coils via LZ-AHU kits. Factory LZ-CG...-O and dual-pump LZ-CG...D-O skids deliver 5.7–292 m³/h at 6 bar with Wilo pumps. Wilo pumps, expansion vessels, probes, and EEV kits are sourced.
- LUQ-E inverter condensing units 10–73 kW (up to 219 kW)
- LZ-CG...-O / D-O pump skids: 5.7–292 m³/h, 6 bar max
- Wilo circulation pumps for water and 50% glycol loops
- Heated control panels, expansion tanks, and LZ-AHU kits
LZ Controls, Valves & Interfaces
Factory controls cover LZ-AHU155VA2 / 360TA2 / 560TA2 DX interface kits with EEVs and probes, chiller remotes LZ-MIPW / MIPS / MPPW2 / CEPW5, and VRF remotes LZ-UPW4F / UPW6 / UPW7 / HJPW. Piping assemblies use LZ-V2 / V4 valves and ZRU-P kits. Exact spares match by code.
- LZ-AHU155VA2 / 360TA2 / 560TA2 DX interface modules
- Chiller controllers LZ-MIPW, LZ-MIPS, LZ-MPPW2, LZ-CEPW5
- Wired and touch VRF remotes LZ-UPW / LZ-HJPW / LZ-KMP
- LZ-V2 / LZ-V4 3-way motorized valves and ZRU-P kits
Chiller Plant Architecture & Hydronic Skids
Central chilled-water plants combine Series C modular air-cooled scroll chillers (33–260 kW per module, linking up to 16 units to 4160 kW with economizers and EER up to 7.1), Series X DC-inverter chillers down to -10 °C, and scroll or screw free-cooling chillers.
Hydronic circulation is handled by factory-assembled LZ-CG...-O single-pump and LZ-CG...D-O dual-pump modules equipped with Wilo pumps, expansion tanks, and heated control cabinets for 5.7–292 m³/h flow at 6 bar across water and up to 50% glycol circuits.
VRF Systems LMV & Precision Close Control
LMV multi-zone VRF systems in NEO and EVO series run full-inverter compressors and fans with up to 130% diversity ratio, spanning Mini C (8–17.5 kW), Citadel V6 (20–90 kW), modular Alliance V6 (25.2–270 kW), water-cooled Submarine, and 3-pipe heat recovery units.
Data centers, telecom rooms, and clean laboratories use close-control cabinets from 5.5–20 kW (GMCC rotary inverter) to 27–120 kW (Hitachi scroll inverter) featuring EC fans, EEVs, Modbus RS485 BMS integration, 64-unit group rotation, and -40 to +45 °C operation.
VENT Air Handling, LUR Rooftops & DX Integration
VENT central air handling units cover industrial, hygienic (F5–F9, H10–H14 filters, UV sanitization), arctic (-60 °C without plastic parts), rooftop, and pool dehumidifier builds, while compact ERVs provide up to 85% heat recovery with EC motors and GTC controls.
DX cooling coils in AHUs connect to LUQ-E inverter condensing units (10–73 kW, linked up to 219 kW) via LZ-AHU interface kits, and large single-zone halls use factory-charged LUR-WF / LUR-WFR 22–450 galvanized rooftops.
LESSAR and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of LESSAR and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for ULT AG
- Equipment and parts for Ultrafilter Belux
- Equipment and parts for VYC Industrial
- Equipment and parts for Tecnocontrol
Documents and sources
- LESSAR official global website
- About LESSAR brand and Tradecon LLC
- LESSAR PROF series and LZ-CG hydronic modules
- LESSAR chillers and free-cooling systems
- LESSAR LSF fan coil units
- LESSAR LMV VRF systems (NEO and EVO)
- LESSAR NEO VRF outdoor units
- LESSAR EVO VRF outdoor units
- LESSAR VENT central air handling units
- LESSAR VENT compact ERV and AHU units
- LESSAR LUR-WF / WFR rooftop air conditioners
- LESSAR close-control units up to 20 kW
- LESSAR close-control units up to 120 kW
- LESSAR LUQ-E inverter condensing units
- LESSAR LZ-AHU interface kits for condensing units
- LESSAR LZ-V2 / LZ-V4 3-way valve kits
- LESSAR chiller control systems LZ-MIPW / MIPS
- LESSAR ZRU-P piping valve assemblies for fan coils
- LESSAR accessories and control components catalog