Tecnocontrol Gas Detectors, Combustion Analyzers & Gas Train Equipment
Italian safety instrumentation and gas train systems from Tecnocontrol: ATEX/SIL GDS800–GDS850 detectors, GDR403/GDR453 refrigerant monitors, CE408 panels, BostonX analyzers, and DN15–DN200 gas valves.
Industrial Fixed Gas Detectors (GDS800 / GDS850, TS255)
Fixed ATEX detectors GDS800 and GDS850 deliver SIL2 hardware and SIL3 software safety for hazardous areas alongside IP65 dual-gas TS255 car park transmitters. TS255CB monitors CO plus petrol vapours, while TS255CN2 tracks CO plus NO₂ via two 4–20 mA outputs and replaceable cartridges.
- ATEX & SIL2 / SIL3 (GDS850)
- Dual 4–20 mA outputs (TS255)
- IP65 housing, 12–24 VDC
- Replaceable sensor cartridges
Gas Detection Control Units (CE408, CE424, CE700, ID250)
The CE408 control panel runs on 230 VAC and accepts 4 to 8 detectors (via ES404 expansion board) plus 5 to 9 SPDT 3 A relays (via ES414). It supports all SE and TS series 4–20 mA transmitters, includes dual 12 V 1.3 Ah backup batteries, and stores 100 log events in an IP54 enclosure.
- Inputs: 4–8 via ES404 board
- Relays: 5–9 SPDT 3 A (ES414)
- IP54 enclosure: 285×230×140 mm
- 2× 12 V 1.3 Ah backup & SD slot
Refrigerant Gas Leak Detectors (GDR300, GDR400, GDR403, GDR450, GDR453)
Industrial GDR403 and GDR453 detectors (remote sensor up to 3 m) monitor NH₃, CO₂, R134a, R404A, R407C, R410A, R507, R449A, R32, R290, and R600 leaks. Each IP67 unit integrates 4–20 mA / 1–5 V / 2–10 V analog outputs, Modbus RS485, 3 relays, Bluetooth diagnostics, and a replaceable cartridge.
- Analog + Modbus RS485 + 3 relays
- Gases: NH₃, CO₂, HFC, R290/R600
- IP67 rated, −40 °C to +60 °C
- Remote probe up to 3 m (GDR453)
Portable Gas Monitors (Easygas, NE700G - G450, NE401, NE700)
Easygas portable monitors provide single-gas personal protection during maintenance in confined spaces and gas trenches. Multigas detectors NE700G - G450, NE401, and NE700 simultaneously track oxygen, flammable gases, and toxic hazards with acoustic and visual alarms.
- Single-gas: Easygas series
- Multigas: NE700G - G450, NE401
- Confined-space safety duty
- Replaceable cells & calibration
Combustion & Tightness Analyzers (BostonX, AN401, ST200PTB, KP400)
The BostonX flue gas analyzer measures boiler emissions and combustion efficiency across commercial and industrial heating plants. Fixed AN401 modules monitor oxygen and toxic flue components, while the ST200PTB digital manometer and KP400 kit automate gas pipeline tightness tests.
- Flue gas analyzer: BostonX
- Fixed sensor unit: AN401
- Tightness testing: ST200PTB
- Sealing kit KP400 & probes
Commercial & Boiler Room Detectors (Beta SE330–SE396, Gamma SE221K, Yukon)
Beta series detectors (SE330, SE333, SE396, SE320EC, SE325EC, SE330IC2) use factory-calibrated replaceable cartridges for natural gas, LPG, CO, and CO₂. Gamma SE221K, Oasi tabletop units, and Yukon Wi-Fi detectors provide acoustic-optical alarms and relay outputs for shut-off valves.
- Beta series: SE330 / SE333 / SE396
- CO & CO₂: SE320EC / SE330IC2
- Replaceable sensor cartridges
- Relay & Wi-Fi versions (Yukon)
Gas Solenoid & Safety Shut-Off Valves (AV, EV, SV OPSO, RV, JV)
Automatic reset solenoid valves (AV015FO-HC, AV040FO, AV025SO, AVD100SO, DN15–DN150) and PED manual reset valves (DN15–DN200, 550 mbar to 6 bar) isolate gas feeds on alarm. Safety devices include SV OPSO slam shut-off valves up to DN100, RV relief valves, and JV/JVD jerk handle valves.
- Sizes: DN15–DN200, up to 6 bar
- Fast & slow opening models
- SV OPSO shut-off & RV relief
- Magnetic sensor & ATEX box
Gas Filters, Pressure Regulators & Diesel Pumps (Rexi-HC, DIN 3386, PO150)
Balanced Rexi and Rexi-HC regulators (up to 20 bar), UNI EN 88 governors (DN15–DN100), and RG-SSV units stabilize burner pressure. EN 13611 / DIN 3386 gas filters (DN15–DN200, 6 bar) use replaceable cartridges, alongside CPI indicators, VR001 modules, and PO150/EL200 pumps.
- Rexi / Rexi-HC up to 20 bar
- DIN 3386 filters up to DN200
- CPI indicators & VR001 units
- PO150 / EL200 diesel pumps
Selecting Tecnocontrol Gas Detection & Combustion Analysis Systems
For boiler rooms, industrial refrigeration plants, and underground car parks, Tecnocontrol pairs fixed detectors with centralized CE408 (4–8 channels via ES404, up to 9 relays via ES414), CE424, or CE700 panels.
Hazardous-area installations deploy ATEX and SIL2/SIL3 rated GDS800/GDS850 transmitters, while parking garages rely on IP65 dual-gas TS255CB and TS255CN2 units.
Refrigeration machinery rooms monitoring NH₃, CO₂, or HFC/HFO refrigerants use IP67-rated GDR403 and GDR453 detectors featuring 4–20 mA / 1–5 V / 2–10 V analog signals, Modbus RS485, Bluetooth diagnostics, and remote probes up to 3 m. Commissioning teams rely on the BostonX combustion analyzer and ST200PTB digital pipeline tightness manometer.
Gas Train Equipment & Burner Line Sizing
Industrial gas train assemblies combine DIN 3386 / EN 13611 filters (DN15–DN200, up to 6 bar), balanced direct-acting Rexi / Rexi-HC pressure regulators (up to 20 bar) or UNI EN 88 governors, and fast- or slow-opening solenoid shut-off valves from DN15 to DN200 with optional ATEX enclosures and CPI position indicators.
Overpressure protection is handled by SV OPSO slam shut-off valves up to DN100, RV relief valves, and JV/JVD emergency jerk valves, while remote diesel burner installations integrate IP65 floating-piston PO150/PO141 or rotary EL200/EL201 transfer pumps.
Tecnocontrol and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Tecnocontrol and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Sencon
- Equipment and parts for VYC Industrial
- Equipment and parts for Seatronics
- Equipment and parts for Impact Subsea
Documents and sources
- Tecnocontrol official site — product overview and 50+ years profile
- Tecnocontrol Industrial Gas Detection — control units and fixed detectors
- CE408 gas detection control unit for 4–8 sensors (ES404, ES414)
- GDR403 industrial refrigerant gas detector with Modbus RS485 and IP67
- GDR453 refrigerant gas detector with remote sensor up to 3 m
- TS255 dual-gas car park transmitter (IP65, replaceable cartridges)
- Tecnocontrol portable measurement and leak detection instruments
- Gas pipeline leak test systems — ST200PTB automatic manometer
- Tecnocontrol Gas Train Equipment — valves, filters and regulators overview
- Automatic reset gas solenoid valves DN15–DN150
- Manual reset gas solenoid valves DN15–DN200 (PED CE 0496/0497)
- Gas safety devices — SV OPSO slam shut-off, RV relief and JV/JVD valves
- Gas filters DIN 3386 / EN 13611 (DN15–DN200, up to 6 bar)
- Gas pressure regulators Rexi / Rexi-HC (20 bar) and UNI EN 88 governors
- Gas train accessories — CPI position indicators, VR001, PS003 switches
- Diesel oil auxiliary motor pumps PO150/PO141 (IP65) and EL200/EL201