ULT AG (ULT) industrial air filtration, fume extraction & drying systems

Industrial extraction, filtration and process air drying systems from ULT AG (ULT): LAS, LRA, ASD, ACD, AOD, JUMBO Filtertrolley and ULT Dry-Tec.

Laser fume extraction — LAS series

The LAS series covers storage-filter units (LAS 160.1 to LAS 1200) and pulse-jet cartridge collectors (LAS 300 PF to ULT 2500.1) delivering 190 to 6,800 m³/h and up to 20,200 Pa. Multi-stage media protect optics during cutting, marking and welding. H-Ex variants handle combustible laser dust.

  • LAS 160.1–1200 / 300 PF–2500.1
  • Airflow 190–6,800 m³/h
  • Vacuum up to 20,200 Pa
  • HEPA H13/H14, carbon & pulse-jet

Soldering fume extraction — LRA series

LRA extractors (LRA 160.1, LRA 200.1, LRA 400.1 and LRA 1200) serve hand soldering benches as well as wave, selective and reflow lines. Standard HEPA H13 stages (upgradable to H14) and gas filters capture sticky flux aerosols and aldehydes. Mobile JUMBO LRA adds benchtop flexibility.

  • LRA 160.1 / 200.1 / 400.1 / 1200
  • Airflow 190–1,500 m³/h
  • Vacuum 2,600–9,000 Pa
  • Standard HEPA H13, H14 option

Industrial dust collectors — ASD series

The ASD line combines storage units (ASD 160.1 to 1200 SF) and cleanable cartridge collectors (ASD 300 PF, ASD 500, ASD 1500 and ULT 2500.1). Systems meet dust classes L (<1%), M (<0.1%) and H (<0.005%) with ATEX H-Ex options. Ideal for grinding, milling and powder handling.

  • ASD 160.1–1200 SF / 300 PF–2500.1
  • Dust classes L, M and H
  • ATEX / H-Ex options
  • Airflow 190–6,800 m³/h

Vapors, gases & odors — ACD series

ACD adsorption units (ACD 160.1 to 1200 plus Ex-rated ACD 220 Ex, ACD 400.1 Ex and ACD 1200 Ex) remove solvent vapors, adhesives and chemical odors. Filtration pairs coarse >10 µm pre-filters and HEPA/ULPA stages with activated carbon or chemisorption beds.

  • ACD 160.1–1200 & Ex models
  • Airflow 190–1,700 m³/h
  • Vacuum 1,100–9,000 Pa
  • Activated carbon & chemisorption

Oil & emulsion mist separators — AOD series

The AOD series (including AOD 200 and AOD 1000) extracts oil and coolant emulsion mist from CNC turning, milling and drilling enclosures. Separated lubricant drains into a collector for reuse while HEPA and sorption stages clean exhaust air for workshop recirculation.

  • AOD 200 & AOD 1000 units
  • Oil & emulsion mist separation
  • HEPA & sorption after-filters
  • Coolant recovery drainage

JUMBO Filtertrolley & extraction arms

Mobile JUMBO Filtertrolley units (LAS, LRA, ASD, ACD plus LabCat, Med and Restauro editions) support flexible point-of-use extraction with low noise. Source capture uses Alsident arms (System 50, 63, 75, 100) and Flextractor hoses, nozzles and hoods positioned right at the emission zone.

  • JUMBO LAS / LRA / ASD / ACD
  • LabCat, Med & Restauro editions
  • Alsident System 50 / 63 / 75 / 100
  • Flextractor arms & capture hoods

Process air drying — ULT Dry-Tec & CoTes

Modular ULT Dry-Tec and ULT CoTes-Line adsorption dryers deliver dew points down to -70 °C (-94 °F) and residual humidity of 0.05–40% RH. A rotating sorption wheel removes moisture continuously for battery cell, chemical and pharma lines, paired with ULT Cool-Tec heat-recovery modules.

  • ULT Dry-Tec & CoTes-Line
  • Dew point down to -70 °C (-94 °F)
  • 0.05–40% relative humidity
  • ULT Cool-Tec pre/after-coolers

Legacy systems — SRA, AMS & 150–1000 series

ULT continues filter element and spare part support for discontinued welding units SRA (200–1200, SRA PN, SKP 220, SKW 20/30), earlier LAS/LRA/ASD/ACD 150–1000 models, AOD 220/250 and AMS dry dust collectors. Replacement filters and upgrade selection remain available.

  • SRA 200–1200 / SKP 220 / SKW
  • Early LAS/LRA/ASD/ACD 150–1000
  • AMS series (discontinued 2012)
  • Continued filter & spare support

Selecting ULT AG (ULT) systems by contaminant, airflow and vacuum

ULT AG systems are matched to process emissions, required airflow (190 to 6,800 m³/h) and static vacuum (1,100 to 20,200 Pa).

The LAS series serves laser processing, LRA handles soldering fumes, ASD targets dry dust in classes L/M/H, ACD adsorbs solvent vapors and odors, and AOD separates oil and emulsion mist.

High-dust applications use pulse-jet cleanable cartridge units (LAS/ASD 300 PF through ULT 2500.1), while explosive atmospheres require ATEX / H-Ex variants equipped with safety vents and flame barriers.

ULT Dry-Tec process air drying and ULT ProSight control

For moisture-critical lines such as lithium-ion battery cell assembly, pharmaceuticals, chemicals and electronics, ULT Dry-Tec Line and ULT CoTes-Line adsorption dryers combine rotating sorption wheels and ULT Cool-Tec heat-recovery modules to reach dew points down to -70 °C (-94 °F) and 0.05–40% relative humidity.

Modern units integrate the ULT ProSight touchscreen controller with multi-level PIN protection, differential pressure analytics across filter stages, M12 digital I/O, OPC UA machine connectivity and energy-efficient 0.75 kW MD.20 blowers.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.