3M Liqui-Cel / Solventum Membrane Contactors
Selection of 3M Liqui-Cel / Solventum EXF, SP, MM, and TMCS hollow-fiber membrane contactors, replacement cartridges, and seal kits for ultrapure water and process degassing.
3M Liqui-Cel / Solventum EXF (Extra-Flow) Series
The EXF (Extra-Flow) center-baffled series handles 0.7 to 125 m3/hr (3 to 550 gpm) per module and achieves outlet levels down to 1 ppb O2 and 0.5 ppm CO2 without chemical scavengers. Sizes span 2.5x8 to 14x40 (G280–G990R) using X40, X50, or XIND fibers. High-pressure models reach 300 psi (20 bar).
- Flow: 0.7–125 m3/hr
- Outlet: 1 ppb O2 / 0.5 ppm CO2
- Sizes: 2.5x8 to 14x40
- Pressure: up to 20 bar (300 psi)
3M Liqui-Cel / Solventum SP Series
The SP series by 3M Liqui-Cel / Solventum uses dense asymmetric polyolefin fibers (UP I, UP II, UP II+) with a gas-permeable outer layer. It degasses low surface tension fluids containing surfactants, inks, or solvents without wet-out. Available sizes include SP-0.5x1 to SP-4x28.
- Fiber: dense polyolefin UP I / II / II+
- Fluids: surfactants, inks, solvents
- Sizes: SP-0.5x1 to SP-4x28
- Flow: shellside liquid configuration
3M Liqui-Cel / Solventum MM Series
The MM series is the smallest 3M Liqui-Cel / Solventum degasser line for laboratory and analytical systems. Units G541 (1.7x8.75), G542 (1.7x5.5), and G543 use X50 fiber in a 43 mm body. Flow runs shellside on MM-0.5x1/0.75x1 and lumenside on larger MM models.
- Catalog numbers: G541, G542, G543
- Dimensions: 43 mm OD, 140 / 222 mm L
- Fiber: X50 polypropylene
- Use: lab and analytical debubbling
3M Liqui-Cel / Solventum EXF-14x28 TMCS
The EXF-14x28 TMCS contactor recovers ammonia via transmembrane chemisorption with X50 fiber. It features a PVC vessel, FKM seals, and 4 in / 2 in ANSI or JIS flanges rated up to 50% acid. Flow limits are 5–20.4 m3/hr shellside and 2–9.1 m3/hr lumenside at 5–50 °C, 3.1 barg.
- Shell flow: 5–20.4 m3/hr
- Lumen flow: 2–9.1 m3/hr
- Rating: 5–50 °C, 3.1 barg (45 psig)
- Materials: PVC, X50 PP, FKM seals
3M Liqui-Cel / Solventum EXF Replacement Cartridges
Replaceable membrane cartridges restore degassing performance in reusable 3M Liqui-Cel / Solventum EXF housings. Catalog options include G625, M138, M150, M152, M154, and M157 hollow fiber bundles. Each insert matches vessel dimensions and X40/X50 fiber grade.
- Catalog numbers: G625, M138, M150
- Additional codes: M152, M154, M157
- Technology: microporous hollow fiber
- Service: periodic cartridge change-out
Seal Kits, O-Ring Kits, and Gasket Kits
Sealing kits from 3M Liqui-Cel / Solventum prevent liquid bypass into gas ports during cartridge change-outs. Official kits cover Seal Kits (K161, K175, K181, K181EU, K182) and O-ring Kits (K112, K113, K123). Gasket Kit K119 supplies EPDM or Viton gaskets for 4x13 and 4x28 SS vessels.
- Seal Kits: K161, K175, K181, K182
- O-ring Kits: K112, K113, K123
- Gasket Kit: K119 (EPDM / Viton)
- Fit: EXF and SP 4x13 / 4x28 SS
Retention Ring Kits and Mounting Kits
Retention Ring Kits (K107, RAW50242) stop internal cartridge movement inside EXF-4x13, EXF-4x28, SP-4x13, and SP-4x28 contactors. Mounting Kits (K157, K166, K172, K187, K199, K214) include straps, cradles, and hardware for skid framing. Proper anchoring protects membrane ports under pressure.
- Retention kits: K107, RAW50242
- Mounting kits: K157, K166, K172
- Skid options: K187, K199, K214
- Hardware: straps, cradles, brackets
Cartridge Change-Out and End Cap Tools
Change-out Tool Kits (K141, K148, K224) supply O-ring picks and maintenance tools for 3M Liqui-Cel / Solventum service. Removal Tool K218 pulls spent cartridges from EXF-8x40 and 8x80 RO-style vessels. End Cap Assembly Tool K163 secures end caps on stainless steel EXF-10x28 housings.
- Change-out kits: K141, K148, K224
- Removal tool: K218 (EXF-8x40/80)
- End cap tool: K163 (EXF-10x28 SS)
- Purpose: safe cartridge maintenance
Fiber Selection and Flow Architecture
3M Liqui-Cel / Solventum membrane contactors span microporous polypropylene EXF modules (X40 fiber for O2 removal, X50 for CO2 removal and TMCS, XIND for EXF-10x28 Industrial) and dense asymmetric polyolefin SP series (UP I, UP II, UP II+) for surfactant, ink, and solvent streams.
In EXF, SP, MM-0.5x1, and MM-0.75x1 designs, liquid flows outside the hollow fibers (shellside) while vacuum or sweep gas runs through the lumen. Larger MM units reverse the liquid and gas paths.
Train Sizing, Pre-Filtration, and Skid Integration
High-flow systems split streams across parallel EXF trains (0.7 to 125 m3/hr per unit) and stage up to five modules in series to achieve 1 ppb O2 and 0.5 ppm CO2 without chemical oxygen scavengers.
Upstream water softening and 5-micron absolute pre-filtration protect the fiber bundle, while keeping liquid pressure above gas pressure prevents bubble breakthrough. Vacuum manifolds slope downward for vapor condensate drainage, and integrity checks test shellside holding at 4.1 barg (60 psi).
3M Liqui-Cel / Solventum and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of 3M Liqui-Cel / Solventum and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for 3B Filters
- Equipment and parts for Habermann Aurum Pumpen
- Equipment and parts for Hiton Special Valve
- Equipment and parts for HAFNER Pneumatik
Documents and sources
- Solventum — 3M Liqui-Cel EXF Membrane Contactor Series
- Solventum — Liqui-Cel EXF 8x20 G990R Stainless Steel Contactor
- Solventum — Liqui-Cel EXF Replacement Membrane Cartridges
- Solventum — Liqui-Cel MM Series Membrane Contactors
- Solventum — Design and Operating Guidelines for EXF and SP Series (PDF)
- Solventum — Liqui-Cel EXF-14x28 TMCS Data Sheet (PDF)
- Solventum — Seal Kits for Liqui-Cel Membrane Contactors
- Solventum — O-ring Kits for Liqui-Cel Membrane Contactors
- Solventum — Gasket Kits for EXF and SP Stainless Steel Housings
- Solventum — Retention Ring Kits for 4x13 and 4x28 Contactors
- Solventum — Mounting Kits for Liqui-Cel Membrane Contactors
- Solventum — Cartridge Change-out Tool Kits (K141, K148, K224)
- Solventum — Cartridge Removal Tool K218 for EXF-8x40 and 8x80
- Solventum — End Cap Assembly Tool K163 for EXF-10x28