Ametherm Inrush Current Limiters & NTC Temperature Sensors
Technical specifications and engineering selection for Ametherm SL, MegaSurge MS, AS32, MM35-DIN, Surge-Gard, CL20 PTC inrush current limiters, and PANR, Thermivolt, DG, Accu-Curve, KR/TR NTC sensors.
SL Series Standard Surge Limiters
Ametherm SL series disc NTC thermistors (SL12, SL22, SL32) protect transformers and switching power supplies from turn-on surges. Models such as SL12 10006 and SL32 10015 offer 10.0 ohm cold resistance, 6–15 A steady-state current, and 40–150 J up to 240 V. Rated to 65°C with derating above.
- Parts: SL12 10006, SL22 10008, SL32 10015
- Resistance 10.0 ohm at 25°C, 6–15 A SSI
- Energy rating 40–150 J, max 240 VAC
- UL recognized, rated up to 65°C ambient
MegaSurge (MS) High-Energy Inrush Limiters
UL-recognized MegaSurge NTC thermistors (MS12 to MS35) protect single- and three-phase power supplies, drives, and inverters up to 480 VAC. Ratings span 0.50 to 220.0 ohm, up to 50.0 A steady-state current, and 800 J energy. MS35 handles 62,000 uF at 120 VAC and 1,800 uF at 680 VAC.
- Disc sizes: MS12, MS15, MS22, MS32, MS35
- 0.50–220.0 ohm at 25°C, up to 50.0 A SSI
- Up to 800 J surge energy, UL to 480 VAC
- Max cap 62,000 uF @ 120 VAC (MS35 0R550)
AS32 Series High-Current Surge Limiters
Ametherm AS32 series disc thermistors (29–32 mm diameter) deliver high steady-state current capacity and energy absorption in compact layouts. Covering AS32 0R536 through AS32 50006, the line spans 0.5–50.0 ohm, 6–36 A continuous current, and 250–300 J with UL recognition.
- Models: AS32 0R536 to AS32 50006
- Resistance 0.5–50.0 ohm, 6–36 A SSI
- Energy capacity 250–300 J, UL recognized
- Diameter 29–32 mm, lead spacing 17.1–17.5 mm
MM35-DIN Rail-Mount Industrial Limiters
Ametherm MM35-DIN modules snap onto DIN blocks for high-power control panels without external bypass contactors. Models 0R280-DIN through 1R550-DIN handle 50–80 A up to 65°C, 680 V RMS, and 1,200 J for three-phase motors up to 90 HP and 70 kW drives.
- Parts: MM35 0R280-DIN to 1R550-DIN
- 0.2–1.5 ohm ±25%, 50–80 A continuous
- 680 V RMS max, 1,200 J energy, 38.4 W
- Three-phase drives to 70 kW / 90 HP motors
RTI Surge-Gard (SG) Inrush Limiters
Ametherm owns and manufactures the RTI Surge-Gard metal-oxide NTC line (SG260, SG100, SG220, SG250) to protect diode bridge rectifiers in switching power supplies. Spanning 0.5 to 120 ohm and 1.75–30 A up to 265 V RMS, devices require at least 60 s recovery time.
- Models: SG260, SG100, SG220, SG240, SG250
- 0.5–120 ohm at 25°C, 1.75–30 A Imax
- Max operating voltage 120 / 265 V RMS
- Minimum 60 s cool-down recovery time
CL20 Series Ceramic PTC Precharge Limiters
Ametherm CL20 ceramic PTC thermistors replace fixed resistors in high-voltage precharge and overcurrent protection circuits. Offering five 25°C resistance ratings from 7.0 to 100.0 ohm, CL20 units handle up to 1200 VDC and 600 J across -40°C to +110°C without degradation.
- CL20 ceramic PTC precharge protection line
- Up to 1200 VDC and 600 J max energy rating
- 5 values from 7.0 to 100.0 ohm at 25°C
- Stable across -40°C to +110°C ambient
PANR Ring-Lug & Thermivolt NTC Probes
PANR 103395-34/-342 ring-lug probes feature 10 kOhm ±2% at 25°C, Beta 3950 K ±1%, 18 AWG Teflon leads, and 4000 VAC dielectric withstand from -50°C to +180°C. Thermivolt TVNR 103395-788/-789 integrates a third voltage-monitoring wire rated to 3000 VAC.
- PANR 103395-34/-342 and TVNR 103395-788/-789
- 10 kOhm ±2% at 25°C, Beta 3950 K ±1%
- 4000 VAC (PANR) / 3000 VAC (Thermivolt)
- 10 s thermal time constant, -50°C to +180°C
KR/TR/STC SMD, Glass DG & Accu-Curve Sensors
Ametherm KR (0805/1206) and TR (0603/0805) SMD thermistors cover 250 ohm to 150 kOhm, while STC chips span 100 to 5000 ohm across -55°C to +150°C. Moisture-proof glass DG and interchangeable Accu-Curve (ACL-011) units replace legacy RTI and Ketema-Rodan parts without recalibration.
- KR0805/1206, TR0603/0805, STC0134–STC0144
- SMD 250 ohm–150 kOhm, STC 100–5000 ohm
- Glass-encapsulated DG and Accu-Curve ACL-011
- Supports legacy RTI / Ketema-Rodan / AMETEK-Rodan
Selecting Inrush Current Limiters for Industrial Power Systems
For switching power supplies, VFDs, inverters, and transformers, Ametherm SL, AS32, MegaSurge MS, and MM35-DIN thermistors are sized by cold resistance R25, steady-state current up to 65°C (with derating above), and capacitor bank energy E = 0.5 × C × Vpeak².
High-voltage DC precharge circuits up to 1200 VDC use CL20 ceramic PTC thermistors rated up to 600 J, while three-phase cabinets up to 70 kW / 90 HP mount MM35-DIN rail modules without external bypass relays.
NTC Temperature Sensing Across Probes, SMD Chips, and Legacy Parts
PANR 103395 ring-lug probes provide 4000 VAC dielectric strength for battery terminals and power busbars, while Thermivolt TVNR three-wire sensors combine temperature sensing with voltage monitoring up to 3000 VAC.
Board-level assemblies utilize KR/TR SMD thermistors and STC chips across curves A, B, C, J, and W, moisture-sealed glass DG parts, calibration-free Accu-Curve (ACL-011) elements, and legacy RTI / Ketema-Rodan / AMETEK-Rodan sensors.
Ametherm and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Ametherm and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for TDK / EPCOS
- Equipment and parts for Souriau / SOURIAU-SUNBANK
- Equipment and parts for Samtec
- Equipment and parts for Broadcom / Avago Technologies
Documents and sources
- Ametherm — Official Manufacturer Homepage (Carson City, USA)
- About Ametherm — ISO 9001:2015, UL and CSA Approvals
- Ametherm New Products — Thermivolt, CL20 PTC, PANR 103395-342, ACL-011
- AS32 Series Inrush Current Limiters — Ratings and Dimensions
- MegaSurge Series (MS12–MS35) — High-Energy Inrush Limiters to 480 VAC
- MM35-DIN Series — 50–80 A, 680 V RMS, 1,200 J DIN-Rail Limiters
- Transformer Inrush Protection & SL Series — Energy Selection and 65°C Derating
- RTI Surge-Gard (SG) Inrush Limiters — Specifications and 60 s Recovery
- PANR 103395-34 Lithium-Ion Battery Terminal NTC Sensor (4000 VAC)
- KR, TR and STC Surface Mount NTC Thermistors — Dimensions and R-T Tables
- NTC Thermistor Applications — Glass DG, Accu-Curve and Steinhart-Hart Equations
- Legacy RTI, Ketema-Rodan and AMETEK-Rodan Thermistor Sensor Catalog