Hankwang Electric Industrial Power Equipment

South Korean switchgear (7.2–24 kV, E-GIS, MCSG), HMC8000 motor control centers, HK-N/TN ATS, ATB-EX/ATBC transfer breakers, BPIS/CTTS bypass systems, and VTB vacuum units.

High-Tension Switchgear, E-GIS & MCSG

Switchboards for 7.2, 15, and 24 kV feature a 3-level compartmentalized layout (2350×1800 mm) for substations. The line covers KERI-tested MCSG, eco-friendly E-GIS, and SIS units with optical arc sensors. Spares cover VCBs, LBS, 200 A fuses, arresters, CTs, and PT trucks.

  • Voltage ratings: 7.2 / 15 / 24 kV
  • Series: MCSG, E-GIS, SIS, F2/G
  • Optical arc & PD detection
  • Parts: VCB, LBS, CT/PT, arresters

HMC8000 Motor Control Centers (MCC)

HMC8000 motor control centers use drawer units up to 800 A in 1/4, 1/2, 1, and 2–3 module sizes. Front 1–3 step withdrawal isolates circuits while keeping enclosure IP protection under live bus. Permanent-magnet contactors (PM MC) cut holding power by 95% without coil heating.

  • Series: HMC8000 up to 800 A
  • Drawers: 1/4, 1/2, 1, 2–3 modules
  • PM MC contactors (-95% standby)
  • Parts: drawers, PM MC, interlocks

Automatic Transfer Switches ATS HK-N / HK-TN

ATS N-type (HK-63N–250N) and TN-type (HK-125TN–3200TN) units operate at AC 600 V / DC 125 V in 2P/3P/4P. Short-time withstand Icw reaches 5 kA on N-type and 50 kA on HK-3000/3200TN with 5,000 electrical cycles. Spares cover A/B close coils, AUX contacts, and control relays.

  • HK-N: 63–250 A | HK-TN: 100–3200 A
  • Rated Ue: AC 600 V / DC 125 V
  • Short-time Icw: 5 to 50 kA
  • Parts: A/B coils, AUX, control units

Automatic Transfer Breakers ATB-EX & ATBC

ATB breakers combine two ACBs per IEC 60947-6-1 (Ui 1000 V, Ue 690 V AC) with overlapping neutral. ATB-EX covers 630–6000 A (Icw 50–100 kA at 460 V), while compact ATBC spans 400–1600 A (32 kA). Spares include 24 VDC–220 VAC motor chargers, coils, and OCR/GR relays.

  • ATB-EX: 630–6000 A (50–100 kA)
  • ATBC: 400–1600 A (32 kA / 67.2 kA)
  • Fixed & draw-out (4-position rail)
  • Parts: motor charger, OCR/GR, coils

BPIS Bypass Isolation, CTTS & HANpro3000

MV BPIS panels (7.2, 12, and 24 kV; 630–1600 A; 25–31.5 kA) isolate the main VTB on bypass without dropping load. Closed-transition CTTS units perform make-before-break transfers (>100 ms) via the HANpro3000 controller. Spares cover HANpro3000 units, interlocks, and bypass drives.

  • MV BPIS: 7.2 / 12 / 24 kV, 630–1600 A
  • Withstand: 31.5 kA (12 kV) / 25 kA (24 kV)
  • CTTS closed-transition (>100 ms)
  • HANpro3000 controller & mimic panel

Double Vacuum Transfer Breakers (VTB)

VTB units (7.2–12 kV and 24 kV) meet IEC 60947-6-1, IEC 62271-100, ANSI C37, and GB/T 1984-2003. Electric motor charging and a dual-OFF neutral position suit draw-out, fixed, and bypass cubicles. Spares include contact arms, plum-blossom contacts, pole posts, and chassis.

  • Ratings: 7.2–12 kV & 24 kV
  • IEC 62271-100 & IEC 60947-6-1
  • Draw-out, fixed & built-in bypass
  • Parts: contact arms, plum contacts, poles

Duplex Distribution Boards & Bus Duct

HKE Duplex boards feature a flame-retardant busbar module with vertical busbars and ELB safety covers, cutting footprint up to 30%. The range also covers KS Bus Duct lines and patented busbar joint kits. Service spares include insulated busbar blocks and ELB protective covers.

  • Up to 30% smaller board footprint
  • Flame-retardant insulated busbar module
  • Bus Duct systems & joint kits
  • Parts: busbar blocks, ELB safety covers

Industrial Switchgear, MCC, and Transfer Switch Portfolio

Founded in 1960 in South Korea, Hankwang Electric Ind. Co., Ltd. (HKE) manufactures low- and medium-voltage power equipment up to 24 kV, including 3-level high-tension switchboards (7.2 / 15 / 24 kV), KERI-tested arc-resistant MCSG, eco-friendly E-GIS, and KS-compliant Bus Duct systems.

For industrial plants, data centers, and power utilities, the lineup includes HMC8000 draw-out motor control centers (up to 800 A) with permanent-magnet contactors, HK-N/TN ATS (63–3200 A), ATB-EX (630–6000 A) and ATBC (400–1600 A) transfer breakers, MV BPIS/CTTS bypass systems with HANpro3000 controllers, and 7.2–24 kV VTB units.

Engineering Selection & Homonym Clarification

Equipment selection relies on system voltage class (600 V / 690 V / 7.2–24 kV), rated current (63–6000 A), short-time withstand current (5–100 kA), pole configuration (2P/3P/4P with overlapping neutral option), fixed or draw-out cassette structure, and IEC 60947-6-1 / IEC 62271-100 compliance.

Hankwang Electric (hkelec.co.kr) strictly denotes the South Korean switchgear and power apparatus manufacturer and should not be confused with Hankwang / HK Laser metal-cutting machinery or Hankwang Opto optical lens producers.

Hankwang Electric and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Hankwang Electric and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.