Hangzhou Shanli Purify (Shanli) Air Dryers, Filters & Chillers

Technical selection of Hangzhou Shanli Purify / Shanli refrigerated and desiccant air dryers, compressed air filters, separators, industrial chillers, and heat recovery units.

SDLF & SDLF-BP Refrigerated Air Dryers

Shanli SDLF and variable-speed SDLF-BP refrigerated dryers stabilize pressure dew point at +2 to +10 °C. Standard units handle 0.6–1.6 MPa and inlet air up to 60 °C using R134a, R410a, or R407c. Serviceable parts cover scroll compressors, expansion valves, plate-fin exchangers, and drains.

  • Flow 0.65–90+ Nm³/min
  • Pressure 0.6–1.6 MPa
  • Dew point +2 to +10 °C
  • Refrigerants R134a / R410a / R407c

SDXW Heatless Desiccant Dryers

SDXW-1PB through SDXW-300PB heatless desiccant dryers run on a 10-minute PSA cycle. Dual towers with activated alumina achieve ≤ -20 °C dew point at 0.5–1.0 MPa and inlet up to 45 °C. Replacement items include desiccant media, switching valves, purge silencers, and PLC controllers.

  • Flow 1.2–310 Nm³/min
  • Pressure 0.5–1.0 MPa
  • Dew point ≤ -20 °C
  • Cycle time 10 min

SDXJ Micro-Heated Desiccant Dryers

Micro-heated SDXJ-1PB to SDXJ-300PB dryers combine thermal heating with low purge over a 2–8 h cycle. Heaters rated 1–120 kW regenerate activated alumina beds evenly at 0.5–1.0 MPa. Service parts cover heating elements, temperature probes, switching valves, and control boards.

  • Flow 1.2–310 Nm³/min
  • Heater power 1–120 kW
  • Cycle time 2–8 hours
  • Power 220V / 380V

SDXY & SDXG Zero-Purge Desiccant Dryers

Compression-heat SDXY-30PB-I to 180PB-I (inlet ≥ 100 °C) and blower-purge SDXG-15PB-I to 150PB-I dryers eliminate purge air loss. An 8-hour cycle with PLC interlocks reaches ≤ -20 °C dew point. Spare parts include blowers, heaters, cooling coils, and switching valves.

  • SDXY: 30–180 Nm³/min
  • SDXG: 16–160 Nm³/min
  • Blowers 2.2–13 kW
  • Three-stage drainage

SDZF/SDZW Combined & SDXM Modular Dryers

Combined SDZF/SDZW units pair refrigerated pre-drying with desiccant towers for -40 to -70 °C dew points. Modular SDXM-1W to 40W dryers (1.2–43.5 Nm³/min) reach -40 °C with 7-inch PLC and RS485. Service parts cover molecular sieves, valves, compressors, and HMI panels.

  • Dew point -40 to -70 °C
  • SDXM: 1.2–43.5 Nm³/min
  • Pressure 0.6–1.0 MPa
  • 7-inch PLC with RS485

SAGL, SAGX & Sterile Compressed Air Filters

Precision filters SAGL (grades HC/HT/HA/HF/HH down to 0.01 µm and 0.003 ppm), dust units FC (≤ 1 µm), oil removers SAGX, and PTFE sterile housings SAGL-CJ operate at 0.6–1.0 MPa. Steam versions SLAF-ZQ handle up to 130 °C. Spares include filter cartridges, O-rings, and differential gauges.

  • Filtration 3 / 1 / 0.01 µm
  • Oil carryover to 0.003 ppm
  • Flow 0.65–310 Nm³/min
  • Sterile SAGL-CJ up to 130 °C

SAZJ Intake Filters, SAYF Separators & SAHL Aftercoolers

SAZJ-40 to 450 self-cleaning compressor intake filters (80–980 Nm³/min, 100%/3 µm, ≤ 270 Pa) feature automatic pulse backflush and 4–20 mA output. SAYF-1 to 450 separators remove ≥ 99% moisture, while SAHL aftercoolers drop gas from 140 °C to ≤ 45 °C. Spares cover cartridges and drains.

  • SAZJ: 80–980 Nm³/min, 4–20 mA
  • SAYF: 1.2–450 Nm³/min, ≥ 99%
  • SAHL: inlet ≤ 140 °C, out ≤ 45 °C
  • SAYF drop ≤ 0.003 MPa

Industrial Water Chillers & Heat Recovery Units

Shanli industrial water chillers (air-cooled scroll and water-cooled screw, +5 °C and -15 °C) run on R134a, R407C, or R22. Waste heat recovery units reclaim compressor thermal energy for plant hot water circuits. Spares include compressors, plate heat exchangers, pumps, and controllers.

  • Chilled water +5 °C and -15 °C
  • Scroll and screw compressor units
  • Refrigerants R134a / R407C / R22
  • Compressor waste heat recovery

Hangzhou Shanli Purify (Shanli) Equipment Portfolio & Dew Point Selection

Hangzhou Shanli Purify (Shanli) builds refrigerated dryers SDLF, desiccant dryers SDXW/SDXJ/SDXY/SDXG/SDXM, combined units SDZF/SDZW, filters SAGL/SAZJ, chillers and heat recovery systems.

SDLF and inverter SDLF-BP refrigerated dryers deliver +2 to +10 °C pressure dew point, while SDXW heatless, SDXJ micro-heated, SDXY compression-heat, SDXG blower-purge, and SDXM modular desiccant units target -20 to -40 °C (and SDZF/SDZW down to -70 °C).

Capacity Correction Factors & Operating Envelope

Catalog capacities of Hangzhou Shanli Purify / Shanli dryers are rated at 0.7 MPa inlet pressure, 38 °C inlet air temperature, and 38 °C ambient temperature. Deviations require pressure and temperature correction factors (CFP/CFT, e.g. 0.75 at 0.5 MPa or 45 °C inlet).

High-inlet applications from ≥ 100 °C match SDXY compression-heat dryers, whereas hot air streams up to 140 °C use SAHL water-cooled finned-copper aftercoolers upstream.

Filtration Stages, Water Chillers & Heat Recovery Integration

Five-grade SAGL coalescing and activated carbon filters (3 µm down to 0.01 µm and 0.003 ppm oil carryover), SAYF cyclone separators (≥ 99% water removal), and SAZJ self-cleaning intake filters (up to 980 Nm³/min, 4–20 mA) safeguard downstream air lines.

Air-cooled scroll and water-cooled screw chillers (+5 °C and -15 °C, R134a/R407C) plus compressor waste heat recovery units complete plant thermal utilities.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.