ZIROX (ZIROX Sensoren & Elektronik) Oxygen Analyzers and Probes

Solid-electrolyte zirconia oxygen analyzers, high-temperature and vacuum probes, probe electronics, H2 sensors, and electrolysis dosing systems from ZIROX Sensoren & Elektronik GmbH.

SGM5T and SGM5S Oxygen Analyzers

The compact SGM5T measures from 2.0e5 down to 0.1 Vol.-ppm O2 and computes air factor lambda, redox quotient, and H2O/H2 ratio. The SGM5S variant adds gas filtering and pressure reduction for brewery CO2 lines. Service parts cover zirconia cells, seals, and RS232 boards.

  • 2.0e5 to 0.1 ppm O2
  • 4–20 mA & RS232
  • Rel. error <3–5%
  • Inlet max 80 °C

SGM7 Compact Oxygen Analyzers

The compact SGM7 analyzer measures 2.0e5 down to 1 Vol.-ppm O2 with an integrated sample pump (5 to 10 l/h), 0/4...20 mA output, and optional RS232 interface. Variant SGM7.2.4 serves reflow soldering inert gas lines. Replacement items include pumps, zirconia cells, and seals.

  • 2.0e5 to 1 ppm O2
  • Built-in pump 5–10 l/h
  • Swagelok 3 mm, IP40
  • 135×100×240 mm, 3 kg

ZR5 OEM Oxygen Measuring Modules

The ZR5 19-inch slot module (21 TE) monitors inert and protective gases from 1 Vol.-ppm to 100 Vol.-% O2 with T90 <= 1 s response. It runs on 24 V DC (20 W) with 0/4...20 mA and optional RS232 outputs. Service kits include the internal 8 l/h pump, zirconia cell, and Swagelok fittings.

  • 1 ppm to 100 Vol.-%
  • Response T90 <= 1 s
  • 19" 21 TE, 24 V DC
  • 0/4–20 mA & RS232

SS31H Flue and Process Gas Probes

The SS31H probe in 1.4841 steel (300 to 1800 mm length) measures -0.01 to 20.6 Vol.-% O2 at 700 to 800 °C directly in firing plants and furnaces. An integrated 36 V / 160 VA heater and type B thermocouple keep cell conditions stable. Spares cover heater inserts, terminal heads, and sleeves.

  • -0.01 to 20.6 Vol.-%
  • 700 to 800 °C, 1.4841
  • Length 300–1800 mm
  • Type B, IP52 / IP65

KS20 High-Temperature Ceramic Probes

The KS20 ceramic probe (Al2O3 Ø25 mm, length 300–1500 mm) operates at 700–1400 °C (peaks 1450 °C) across 100 to 10^-29 Vol.-% O2 with TÜV TA Luft approval. Built for boilers, incinerators, and ceramic kilns. Spares cover Al2O3 tubes, type B thermocouples, and sleeves.

  • 700–1400 °C (1450 peak)
  • Al2O3 tube Ø25 mm
  • 100% to 10^-29% O2
  • TÜV TA Luft approved

SS27 and MS27 Miniature Probes

Miniature probes SS27 (oxidizing, 15 ppm to 20.6 Vol.-%) and MS27 (reducing / >100 ppm) feature a 10 mm body, M18x1.5 (65 mm) or DN40KF (75 mm) mounting, and integrated 24 V DC electronics. Warm-up takes 5 min with 4–20 mA output. Service covers full probe assemblies and seals.

  • Ø10 mm, M18x1.5 / KF40
  • 24 V DC, 17 W, IP42
  • 4–20 mA, 5 min warm-up
  • Gas max 300 °C

XS22 Vacuum and SS20.BQ / XS11.QE Probes

The XS22 vacuum probe (KF40 flange, He leak rate < 10^-8 mbar l/s) measures oxygen partial pressure down to 1e-5 Pa in PVD and magnetron sputtering chambers. Combining Q-probe SS20.BQ (500–1100 °C) with QE-probe XS11.QE (760 °C catalyst) controls KN and KC in nitriding furnaces.

  • XS22: KF40, 1e-5 Pa
  • SS20.BQ: 500–1100 °C
  • XS11.QE: 760 °C head
  • 1.4841 steel, 0–1500 mV

E2000 / E2010 / E713 Electronics, TCS and SGM5EL

The E2000 unit (IP65, 110–230 V) drives ZIROX probes with an internal reference pump, cell-resistance check, 2x 0/4–20 mA, and RS232; E2010 and E713 fit 96×96 mm panels (24 V DC). The lineup also includes the TCS thermal conductivity H2 sensor (0–100%, IP65) and SGM5EL electrolysis unit.

  • E2000: IP65, 2x 4–20 mA
  • E2010 / E713: 96×96 mm
  • TCS H2: 0–100%, IP65
  • SGM5EL: test gas dosing

Selecting ZIROX Analyzers vs. Direct Insertion Probes

Choosing between extractive analyzers (SGM5T, SGM5S, SGM7, ZR5) and in-situ probes (SS31H, KS20, SS27/MS27) depends on process gas temperature, pressure, and reducing components.

SGM5T and SGM7 accept gas up to 80 °C at max 100 mbar and 20 mbar overpressure, whereas SS31H (700–800 °C) and ceramic KS20 (700–1400 °C) measure directly inside hot flues and kilns.

Direct in-situ zirconia measurement eliminates sample cooling distortions in reducing atmospheres and enables lambda, H2O/H2, and CO2/CO ratio calculation when paired with the E2000 electronics unit.

Vacuum PVD, Heat Treatment, and Electrolysis Systems

For low-pressure PVD, CVD, and magnetron sputtering chambers, the XS22 vacuum probe (KF40 flange, He leak rate < 10^-8 mbar l/s) tracks oxygen partial pressure down to 1e-21 Pa across chamber pressures from 1.5e5 to 1e-5 Pa.

In nitriding and nitrocarburizing heat-treatment furnaces, combining the SS20.BQ Q-probe and XS11.QE catalytic probe (760 °C head) determines KN and KC potentials, while the SGM5EL electrolysis unit doses or removes O2 in N2, Ar, and CO2 gas streams.

ZIROX Sensoren & Elektronik and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of ZIROX Sensoren & Elektronik and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.