Xylem Analytics Analytical Instruments and Process Systems
Selection and specification matching for Xylem Analytics (WTW, YSI, SI Analytics, Bellingham + Stanley, TriOS) online water networks, laboratory titrators, spectrophotometers, refractometers, and replacement sensors.
WTW IQ SensorNet Process Networks
WTW IQ SensorNet System 2020 3G connects up to 20 digital IQ sensors via Ethernet/LAN with backup control. System 282/284 handles up to 4 sensors with RS-485 and USB. Options include System 281, FDO 700 IQ, Varion Plus, and NiCaVis 701/705 IQ NI.
- System 2020 3G: up to 20 sensors
- System 282/284: up to 4 sensors
- Ethernet/LAN, RS-485, USB logbook
- FDO 700 IQ, Varion Plus, NiCaVis
Process Analyzers and Inline Electrodes
Continuous process control pairs wet-chemical Alyza IQ analyzers for ammonium and orthophosphate with Drinking Water Panels. SI Analytics ProcessLine and sterilizable SteamLine pH/ORP electrodes work alongside Ex level sensors, samplers, and armatures.
- Alyza IQ NH4 and PO4 analyzers
- SI Analytics ProcessLine inline pH
- SteamLine sterilizable electrodes
- Ex level sensors and samplers
Electrochemistry and IDS Digital Platform
WTW and SI Analytics meters measure pH, ORP, ISE, conductivity, and dissolved oxygen in labs and field sites. IDS sensors digitize signals inside the probe head for 100 m cables or 10 m Bluetooth modules while storing GxP calibration history.
- inoLab Multi IDS & MultiLab Pro IDS
- Direct A/D conversion inside sensor head
- Up to 100 m cable or 10 m Bluetooth
- Built-in GxP calibration status memory
Electrodes, Cells, and SC-FDO Replacement Caps
Spare parts cover SenTix 41/81/Top 41/940 and ScienceLine electrodes with S7, DIN, BNC, or IDS plugs and DIN 19266/19267 buffers. Calibration-free SC-FDO 700 and 701 optical oxygen caps run 3–5 years at up to 10 bar across 0–20.00 mg/l O2.
- SC-FDO 700 / 701 caps (3–5 years)
- 0–20.00 mg/l O2, up to 10 bar
- SenTix & ScienceLine, S7/DIN/BNC/IDS
- DIN 19266/19267 buffers & 3 mol/l KCl
SI Analytics Automatic Titrators and Burettes
SI Analytics offers TITRONIC 300/500 piston burettes and TitroLine 5000, 7000, 7750, and 7800 titrators with exchangeable units and IDS input. Volumetric TitroLine 7500 KF and 7500 KF trace pair with TW 7200 (38) or TW 7450 (72) changers.
- TITRONIC 300 & 500 piston burettes
- TitroLine 5000, 7000, 7750, 7800 IDS
- TitroLine 7500 KF & 7500 KF trace
- TW 7200 (38) & TW 7450 (72) changers
photoLab Spectrophotometers and TriOS Sensors
WTW photoLab 7000 spectrophotometers cover 190–1100 nm, filter photometers use 6 or 12 wavelengths, and pHotoFlex colorimeters pair with 16 mm vial thermoreactors. Inline optics include TriOS LISA UV254, NICO, OPUS, TW Turb, and microFlu V2/HC.
- photoLab 7000 Series: 190–1100 nm
- Filter photometers: 6 or 12 wavelengths
- pHotoFlex & 16 mm vial thermoreactors
- TriOS LISA UV254, NICO, OPUS, microFlu
Bellingham + Stanley Refractometers and Polarimeters
Bellingham + Stanley RFM-T touchscreen and RFM-M keypad refractometers feature IP65 housings, flat prism dishes, over 100,000 readings memory, and sub-15 s results. They support RFID, USB PDF/CSV export, FDA 21 CFR Part 11, plus OPTi handhelds.
- RFM-T, RFM-M & OPTi handhelds
- IP65 housing, reading under 15 s
- Memory for over 100,000 readings
- RFID, PDF/CSV export, 21 CFR Part 11
SI Analytics Capillary Viscometry Systems
SI Analytics viscometry combines Ubbelohde glass capillaries with the ViscoClock Plus electronic timing unit for polymer solutions. Automated setups scale from stand-alone AVS 470 and AVS 370 to AVS Pro III autosamplers, CT 72 thermostats, and CK 310 coolers.
- Ubbelohde capillaries & ViscoClock Plus
- Stand-alone AVS 470 viscosity meter
- AVS 370 & AVS Pro III autosampler
- CT 72 thermostat & CK 310 cooler
Xylem Analytics Multi-Brand Portfolio
Operating within Xylem Inc., Xylem Analytics integrates WTW, YSI, SI Analytics, Bellingham + Stanley, ebro, MJK, OI Analytical, SonTek, and TriOS instrumentation for wastewater plants, drinking water utilities, food and beverage QA, life sciences, and environmental monitoring.
Online Process Monitoring vs. Laboratory Benches
Continuous process control relies on WTW IQ SensorNet System 2020 3G (up to 20 digital sensors, Ethernet/LAN, backup controller) and System 282/284 (up to 4 sensors, RS-485), alongside Alyza IQ wet-chemical analyzers and TriOS spectral sensors.
Laboratory benches feature SI Analytics TitroLine titrators, photoLab 7000 UV-VIS spectrophotometers (190–1100 nm), RFM-T/RFM-M refractometers (IP65, 21 CFR Part 11), and AVS viscometers.
Digital IDS Platform and Consumable Assemblies
IDS sensors digitize signals directly in the probe head for up to 100 m cable runs or 10 m wireless Bluetooth operation while storing GxP calibration history.
Calibration-free SC-FDO 700/701 oxygen sensor caps last 3–5 years up to 10 bar, and SenTix/ScienceLine electrodes match S7, DIN, BNC, or IDS ports.
Xylem Analytics and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Xylem Analytics and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Texas Instruments
- Equipment and parts for MDC Precision
- Equipment and parts for Nor-Cal Products
- Equipment and parts for YORK Co Ltd
Documents and sources
- About Xylem Analytics and brand portfolio (WTW, YSI, SI Analytics, Bellingham + Stanley, TriOS)
- Xylem Analytics China official portal — analyzers and water monitoring systems
- WTW IQ SensorNet modular online process measuring systems
- Process analytics: Alyza IQ analyzers and ProcessLine / SteamLine sensors
- The IDS (Intelligent Digital Sensors) system overview
- Meters and sensors from WTW and SI Analytics for pH/ORP, ISE, DO, conductivity
- Replacement caps SC-FDO 700 / SC-FDO 701 for WTW FDO optical oxygen sensors
- Electrodes, sensors and measurement cells for pH/ORP, conductivity, oxygen and ISE
- TriOS optical water quality monitoring solutions
- SI Analytics titration systems (TITRONIC 300/500, TitroLine 5000–7800, 7500 KF)
- WTW photoLab 7000 spectrophotometers and pHotoFlex colorimeters
- Bellingham + Stanley RFM-T, RFM-M and OPTi digital refractometers
- SI Analytics capillary viscometry (ViscoClock Plus, AVS 470/370/Pro III, CT 72)