Cryomech cryocoolers and helium systems

Technical selection of Cryomech equipment: pulse tube and Gifford-McMahon cryocoolers with helium compressors, HeRL helium reliquefiers, LHeP liquid helium plants and LNP liquid nitrogen plants.

PT410 and PT415 4 K pulse tube cryocoolers

Two-stage pulse tube cryocoolers of the 4 K range. The PT410 gives 1.0 W at 4.2 K and 40 W at 45 K with the CPA289C compressor; the PT415 gives 1.5 W at 4.2 K and 40 W at 45 K with the CPA1110. Both cool down to 4 K in 60 minutes. The 4 K range runs from PT403 to PT450.

  • PT410: 1.0 W at 4.2 K
  • PT415: 1.5 W at 4.2 K
  • Cooldown to 4 K: 60 min
  • PT410/PT415 base: 2.8 K

PT205 compact 2 K cryocooler

A two-stage pulse tube cryocooler for superconducting nanowire single-photon detectors (SNSPDs). It gives 10 mW at 2.5 K and 100 mW at 55 K. The cold head weighs 8.6 kg. It is available with the air-cooled CPA010 compressor for 19-inch racks, using 1.1 kW at 60 Hz.

  • 10 mW at 2.5 K
  • Base: 2.4 K or lower
  • PT205 cold head: 8.6 kg
  • Cold head service: 40,000 h min

Pulse tube cryocoolers for 20 K

Two-stage pulse tube cryocoolers of the 20 K range, from the PT803 (4 W at 20 K) to the PT820 (28 W at 20 K and 130 W at 80 K). The PT810 gives 14 W at 20 K and 80 W at 80 K, has an 8 K base temperature, cools to 10 K in 60 minutes and runs with the CPA289C compressor.

  • PT810: 14 W at 20 K
  • PT810: 80 W at 80 K
  • PT820: 28 W at 20 K
  • PT810 to 10 K: 60 min

Gifford-McMahon cryocoolers for 20–30 K

The 20–30 K GM range runs from the AL63 (18 W at 30 K) to the AL630 (100 W at 20 K). The AL230 gives 60 W at 30 K with a base temperature of 17 K or lower, reached in under an hour. It runs with the CPA2850 compressor; an air-cooled version weighs 174 kg.

  • AL230: 60 W at 30 K
  • AL630: 100 W at 20 K
  • AL230 base: 17 K or lower
  • AL230 to base: under 1 h

Gifford-McMahon cryocoolers for 80 K

The 80 K GM range condenses nitrogen and argon, from the AL60 (60 W at 80 K) to the AL600. The AL600 gives 600 W at 80 K with a base temperature of 25 K or lower; its cold head weighs 42 kg and it runs with the CPA1114 compressor. GM cryocoolers mount vertical, horizontal or angled.

  • AL600: 600 W at 80 K
  • AL60: 60 W at 80 K
  • AL600 base: 25 K or lower
  • AL600 cold head: 42 kg

HeRL helium reliquefiers

HeRL units recondense helium boil-off back into the Dewar or cryostat to close the helium loop and drop in through the existing fill port. They serve MEG magnetometers, MPMS, PPMS, MRI, NMR and superconducting magnets. The HeRL15 on a PT415/CPA1110 liquefies 15 L/day or more.

  • HeRL15: 15 L/day or more
  • HeRL15 recondensing: 27 L/day+
  • HeRL15 to liquid: under 2 h
  • HeRL cooldown: under 4 h

LHeP liquid helium plants

LHeP plants liquefy helium from any room temperature source at 15 to 80 L/day depending on model. They run on a Cryomech pulse tube cryocooler without JT valves and have a touch screen PLC control panel. The LHeP22 gives 22 L/day or more with a 150 L Dewar and a PT415/CPA1110 cryocooler.

  • LHeP22: 22 L/day or more
  • LHeP22 Dewar: 150 L
  • LHeP range: 15–80 L/day
  • LHeP22: 10.0 kW at 60 Hz

LNP liquid nitrogen plants

LNP plants produce liquid nitrogen directly from the air with membrane technology: from 10 L/day on the LNP10 with a 35 L Dewar to 240 L/day on the LNP240 with a 500 L Dewar. Nitrogen purity is 98 % on all models, built on a Gifford-McMahon cryocooler. A level sensor sets standby at a full Dewar.

  • LNP10: 10 L/day, 35 L Dewar
  • LNP240: 240 L/day, 500 L Dewar
  • Nitrogen purity: 98 %
  • Based on a GM cryocooler

Choosing a Cryomech cryocooler

Cryomech is the cryocooler brand of a company in Syracuse, New York, USA, founded in 1963 by William Gifford, one of the inventors of the Gifford-McMahon cycle. In 2023 Bluefors announced the acquisition of Cryomech, which now operates as Bluefors Syracuse.

The type is chosen by temperature. Pulse tube cryocoolers come in 1 K, 2 K, 3 K, 4 K and 20 K ranges plus single-stage 30–80 K units, with no moving parts in the cold head. For 4 K there are the two-stage PT403 to PT450, for 20 K the PT803 to PT820.

GM cryocoolers work at 20–80 K and condense hydrogen, nitrogen and argon: AL63 to AL630 for 20–30 K and AL60 to AL600 for 80 K.

Helium liquefaction and recovery

For a single helium user such as a cryostat, NMR or MRI magnet, HeRL reliquefiers return the boil-off to the Dewar. The HeRL15 on a PT415/CPA1110 cryocooler liquefies 15 L/day or more and draws 10.7 kW at 60 Hz.

For several users there are LHeP liquid helium plants with 15 to 80 L/day and Dewars of 150 to 500 L. With a Cryomech Helium Recovery System, one plant serves several cryostats with different boil-off rates. The LHeP22 gives 22 L/day or more with a 150 L Dewar; the system weighs 434 kg.

Vibration and noise options

A temperature oscillation damping pot fits any Cryomech two-stage pulse tube cryocooler and raises temperature stability to ±5 mK. Only two-stage PT cold heads are offered with a built-in liquefying circuit for external helium circuits, with the liquid leaving through a VCR fitting.

Pulse tube cryocoolers suit vibration-sensitive setups because the cold head has no moving parts, and a low vibration sleeve is offered for them. Electrical isolators are standard on the remote motor line and optional on the compressor and cold head gas ports.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.