LOCHNER LB Electronic congress mashing baths
Congress mashing baths LOCHNER LB Electronic deliver standardized malt and wort analysis compliant with MEBAK, EBC and ASBC standards. The baths feature precise electric heating up to 95 °C, a quiet gear drive and a secondary submerged platinum temperature sensor inside the sample.
- Standardized mashing cycles for congress mash and Hartong temperature analysis
- Platinum resistance temperature sensor with direct immersion into wort sample
- Stainless steel bath housing and agitator components built from grade AISI 316
- Mobile external operator control terminal equipped with clear multi-line display
LOCHNER LB 4 to LB 20 laboratory mashing apparatus
The LOCHNER LB mashing apparatus series encompasses models with 4, 8, 12, 16, 18 and 20 beakers configured for single-phase or three-phase power grids. Units feature dedicated gear drive motors for each agitator, Duran laboratory glass dosing tubes and a digital software control unit.
- Scalable instrument sizes ranging from compact LB 4 units to high-volume LB 20
- Precision machined stainless steel stirring paddles and matching sample beakers
- Calibrated dosing feed tubes fabricated from heat-resistant Duran borosilicate
- Computer data interface for real-time visualization and archiving of mash logs
Lochner Force beer aging and stability chambers
Lochner Force forced aging chambers perform cyclic thermal stability testing of packaged beer in strict compliance with MEBAK standards. Dry air temperature conditioning avoids water bath bottle immersion, eliminating humidity hazards and label damage during laboratory inspection.
- Programmable alternating thermal cycles switching between zero and sixty Celsius
- Dry air conditioning technology eliminating external steam and water condensation
- Embedded microprocessor cycle data logger with direct thermal printer connection
- Dual temperature sensor circuit delivering direct bottle thermal monitoring data
LOCHNER brewery laboratory optical microscopes
LOCHNER optical brewery microscopes are configured for rigorous microbiological monitoring of pure yeast strains, fermentation slurries and filtered beer. The microscope integrates a heavy metal stand, coaxial focus knobs, phase contrast condenser and an optimal 63x optical objective.
- Achromatic and plan achromatic optical lenses spanning 4x up to 100x magnification
- Specialized 63x magnification lens engineered for high-precision yeast counting
- Phase contrast module and darkfield condenser for unpigmented cellular imaging
- Precision mechanical specimen stage with graduated coaxial specimen positioner
LOCHNER LL-21 and LL-26 portable pH meters
Electrochemical meters LOCHNER LL-21 and LL-26 deliver accurate monitoring of hydrogen ion activity and redox potential across mashing and fermentation stages. An impact-resistant enclosure rated IP 57 is paired with a bright color screen and digital DHS sensor recognition.
- Digital automatic identification of DHS standard smart electrochemical pH probes
- Waterproof and dustproof IP 57 enclosure equipped with protective rubber armoring
- Automatic three-point buffer calibration with continuous electrode slope status
- Internal GLP datalogger storing 1000 data points with micro-USB communication link
LOCHNER LL-21 and LL-26 conductivity instruments
Portable conductivity instruments LOCHNER LL-21 and LL-26 monitor electrical conductivity and total dissolved solids in brew water, rinse solutions and final beverage products. Supporting 5-point calibration, automatic temperature compensation and long-term parameter logging.
- Broad measurement range spanning electrical conductivity and dissolved TDS levels
- Automatic calibration sequence supporting up to five reference conductivity points
- Precise automatic temperature compensation with user-defined temperature factor
- Non-volatile memory storage keeping complete measurement logs for quality review
Temperature profile control in LB Electronic mashing apparatus
Standardized congress mashing procedures defined by MEBAK and EBC protocols require precise thermal ramp management during malt sample conversion.
Congress mashing baths LOCHNER LB Electronic incorporate a digital controller and a submerged platinum Pt100 temperature sensor that directly monitors liquid temperature inside the sample beaker.
Electric heating elements increase the water bath temperature at a rate of one degree Celsius per minute up to seventy degrees. Continuous circulation prevents local thermal stratification around the beaker walls.
Operators follow temperature-time curves on the mobile terminal display and export complete logs via standard interfaces.
Preparation of stainless beakers, agitators and Duran dosing tubes
Accurate determination of malt extract yields depends upon the physical precision and surface finish of laboratory sample containers. Operating beakers for LOCHNER LB mashing units with 4 to 20 positions are manufactured from polished AISI 316 stainless steel alloy.
Before starting an analysis series, empty numbered beakers undergo precision weighing on analytical balances. Flat-blade stirring paddles lock securely into bayonet drive chucks to maintain uniform clearance against vessel walls.
Distilled water addition is conducted through precision calibrated dosing tubes made of heat-resistant Duran borosilicate glass to compensate for evaporation loss.
Forced beer aging protocols in dry air Lochner Force chambers
Predicting shelf life stability of filtered and unfiltered beers requires controlled temperature cycling to accelerate haze formation. The Lochner Force beer aging chamber executes automated temperature alternation between zero and forty or sixty degrees Celsius without requiring a messy water bath.
Conditioning beer bottles in dry air flow preserves paper labels and prevents humidity build-up inside laboratory facilities.
An integrated microprocessor records measurements from a secondary temperature sensor placed directly inside a reference container, delivering verification logs to an external printer terminal.
Optical alignment and phase contrast setup on LOCHNER microscopes
Microbiological control of brewing yeast cultures and packaged beer is routinely conducted using LOCHNER laboratory optical microscopes. The instrument is positioned on a vibration-isolated work table and aligned according to Koehler illumination principles for uniform field brightness.
A specialized 63x plan achromatic objective provides high-contrast visualization of Saccharomyces yeast cell walls without requiring immersion oil. For detecting wild bacterial contaminants, the revolving nosepiece switches to a phase contrast condenser turret.
Dimmable LED illumination maintains stable color temperature during digital imaging.
Calibration of LL-21 digital pH meters and DHS sensor maintenance
Hydrogen ion activity in mash, sweet wort and finished beer represents a decisive parameter for enzymatic conversion and biological stability. LOCHNER LL-21 portable analyzers utilize smart DHS digital sensor technology, storing calibration factors and verification timestamps within the probe chip.
Prior to production monitoring, operators conduct automated three-point calibration using standard buffer solutions while checking electrode slope efficiency. The sealed IP 57 housing protects internal circuitry from liquid splashes.
Glass measuring electrodes are rinsed with deionized water and preserved in liquid storage electrolyte.
Conductivity monitoring in water treatment and cleaning solutions
Electrical conductivity of municipal and brewing liquor determines mineral balance and buffer capacity throughout mashing.
LOCHNER LL-21 and LL-26 conductivity meters feature four-electrode cells with automatic temperature compensation, providing linear measurement response across varied dilution ranges.
During verification of rinse water following automated clean-in-place cycles, the instrument applies a temperature coefficient of two percent per degree Celsius. Storing logged measurement profiles in non-volatile memory ensures traceable data records during internal brewery quality reviews.
LOCHNER / Lochner Labor + Technik and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of LOCHNER / Lochner Labor + Technik and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for SparkFun Electronics
- Equipment and parts for Nationstar
- Equipment and parts for K.S.Terminals
- Equipment and parts for WEROCO
Documents and sources
- German manufacturer LOCHNER Labor + Technik — official laboratory equipment engineering portal
- LB Electronic mashing bath series — standardized congress mashing instruments for malt analysis
- Lochner Force beer aging test chambers — forced stability testing equipment compliant with MEBAK
- LOCHNER brewery optical microscopes — specialized laboratory instruments for yeast microbiology
- LL-21 series electrochemical instruments — portable pH meters and conductivity testers for breweries
- Sauergut biological acidification kits — pure culture wort pH management for brew mash optimization
- LOCHNER manufacturing facility and contacts — technical service headquarters in Berching Germany