Blancett / Badger Meter Turbine & Positive Displacement Flow Meters

Engineering selection and quotation for Blancett / Badger Meter turbine and gear flow meters (Model 1100, QuikSert, 1200, B1500, FloClean, B1750, 900 Series), B3000/B2900 monitors, pickups, and repair kits.

Blancett / Badger Meter Model 1100 Turbine Flow Meters

Model 1100 turbine meters use a 316 stainless steel housing, CD4MCU rotor, and tungsten carbide bearings for 0.6–5,000 gpm liquid flows up to 5,000 psi with ±1% reading accuracy. Sizes 3/8 to 10 in. fit NPT, BSP, grooved, or flanged lines. Spares include B251 kits and B111109 pickups.

  • Flow 0.6–5,000 gpm (3/8–10 in.)
  • 316 SS body, CD4MCU rotor, ±1%
  • Up to 5,000 psi, −101 to +232 °C
  • B251 kits and B111109 pickup

QuikSert Wafer-Style Turbine Flow Meters (Liquid & Gas B142)

QuikSert wafer meters (B131–B139 liquid, B142 gas) fit between ASME B16.5 flanges without mating flanges. Built in 316L SS with flow straighteners, they meter 0.6–5,000 gpm liquids and 7–350 ACFM gas. Spares include B253 repair kits and B111109 or B111113 pickups.

  • Wafer ASME B16.5 flange mount
  • Liquids 0.6–5,000 gpm, up to 255 bar
  • Gas B142: 7–350 ACFM (−40 to +165 °C)
  • B253 kits, B111109 & B111113 pickups

Model 1200 Corrosive-Environment Turbine Flow Meters

Model 1200 turbine meters (B121-225, B121-275) handle corrosive chemical flows in 1/4 to 3/4 in. NPT lines. Built with 303 SS bodies, CD4MCU rotors, and 440 SS bearings, they rate to 4,000 psi and 0.25–25 gpm. Spares cover B111117 RF pickups, B120101, and B222228 preamps.

  • Flow 0.25–25 gpm (1/4–3/4 in. NPT)
  • 303 SS body, type-440 SS bearings
  • 4,000 psi max, ±1.0% reading accuracy
  • B111117 RF pickup & B222228 preamp

Model 1500 (B1500) High-Linearity Precision Turbine Meters

Model 1500 meters (B150-501 to B150-120) use a helical 17-4 PH rotor and ceramic bearings for clean filtered batching. They achieve ±0.25% accuracy with linearization, ±0.02% repeatability, 0.25–250 gpm range, and up to 408 bar. Spares include B111113 pickups and B220-950 converters.

  • ±0.25% accuracy, ±0.02% repeatability
  • 17-4 PH rotor & ceramic ball bearings
  • 0.25–250 gpm, up to 408 bar (5,922 psi)
  • B111113 pickup & B220-950/951 units

FloClean B16D / B16C 3-A Sanitary Turbine Flow Meters

FloClean B16D / B16C sanitary meters meet 3-A Standard 28-04 for COP/SOP food and pharma lines with Tri-Clamp ends. Built in 316L SS, they meter 0.6–400 gpm up to 69 bar and 149 °C at ±1% accuracy. Spares cover B16C-K03A–K20A repair kits and NEMA 6 B161109 pickups.

  • 3-A Sanitary 28-04 (COP / SOP)
  • 316L SS, Tri-Clamp 3/4 to 2-1/2 in.
  • 0.6–400 gpm, up to 69 bar & 149 °C
  • B16C-K03A–K20A kits & B161109

Positive Displacement Gear Meters B1750 & 900 Series Water Flood Meters

B1750 gear meters (B175-A12 to S90) meter viscous oils and fuels at 0.003–120 gpm (400:1 turndown, ±0.5%, 5,000 psi) without straight runs. 900 Series water-flood vane meters rate to 5,000 psi. Spares include B170109–B170180 sensors and B250-921–932 repair kits.

  • B1750: 0.003–120 gpm, up to 400:1
  • No straight pipe runs, 5,000 psi max
  • 900 Series: 2–90 gpm rotary vane
  • B170109–180 sensors & B250-921–932

Digital Flow Monitors B3000, B2900, B2800 & Explosion-Proof E110

Monitors B3000 (B30AM/AR/XR/ZR-CS), B2900, B2800, and Ex d E110 accept 1–3,500 Hz signals to display rate and total. Options add 4–20 mA loop, 3.6V battery or solar power (B30S), and Modbus RTU over RS-485. Hazardous-area builds use B280-737/742 mount kits.

  • 1–3,500 Hz input, 0.05–0.1% accuracy
  • 4–20 mA, pulse & Modbus RTU RS-485
  • Battery, 4–20 mA loop or solar B30S
  • NEMA 4X / IP66, Ex d & B280-737/742

Repair Kits B251 / B253 / B16C, Pickups, K-Factor Scalers & Converters

Calibrated repair kits B251 (1100), B253 (QuikSert), B16C-KxxA (FloClean), and B250 (900) rebuild rotor assemblies in-line with a new K-factor (except NCC). Spares include B111109/B111126 pickups, B220-885 scalers, B220-873/874/950/951 converters, and B220-220 cables.

  • Kits B251, B253, B16C-KxxA & B250
  • Factory K-factor calibrated (or NCC)
  • Pickups B111109, B111126, B220111
  • B220-885 scalers & B220-873/950

Selecting Blancett / Badger Meter Flow Meters by Fluid, Pressure & Line Size

Selection starts with fluid chemistry, viscosity, line pressure, and end connections: Model 1100 (316 SS, up to 5,000 psi) and wafer-style QuikSert B131–B139 cover 3/8 to 10 in. water and industrial liquid lines, while Model 1200 (303 SS) serves corrosive 1/4 to 3/4 in. chemical streams.

For precision batching and blending, Model 1500 offers ±0.25% linearized accuracy with ceramic bearings; FloClean B16D/B16C meets 3-A 28-04 sanitary rules; Gas QuikSert B142 meters 7–350 ACFM gases; and B1750 gear meters handle high-viscosity oils up to 400:1 turndown.

Flow Monitors B3000 / B2900 / B2800 / E110 & Signal Conditioning

Microprocessor monitors B2800, B2900, B3000, and explosion-proof E110 accept 1–3,500 Hz pickup frequencies and output 4–20 mA, totalizing pulses, and Modbus RTU over RS-485 (up to 127 addresses on B2900 and B3000 Advanced B30A/B30Z).

Power options span 3.6V lithium battery, two-wire 4–20 mA loop, and solar B30S units, alongside B220-885 K-factor scalers and B220-873/874/950/951 frequency-to-analog converters in NEMA 4X / IP66 or Class I Div 1 / ATEX Ex d enclosures.

Field-Replaceable Repair Kits, K-Factor Calibration & Piping Rules

Inline turbine housings stay piped during service when using factory-calibrated rotor kits B251 (Model 1100), B253 (QuikSert), B16C-KxxA (FloClean), or B250 (900 Series), each accompanied by a NIST-traceable K-factor (except nominal NCC kits).

Turbine lines require at least 10 pipe diameters upstream and 5 downstream plus 4–60 mesh upstream strainers, whereas B1750 positive displacement gear meters operate accurately with zero straight-run piping.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.