PMA / West Control Solutions PID Temperature Controllers & Safety Limiters

Engineering selection and quotation for PMA / West Control Solutions single-loop and multi-loop PID controllers (KS 40-1, KS 90-1, KS 98-1/98-2, KS vario), EN 14597 / SIL2 limiters (STB 55, TB 45), Rail Line I/O, and spare modules.

Single-loop PID controllers KS 40-1, KS 41-1, KS 42-1 & KS 50-1

Single-loop PID controllers KS 40-1, KS 41-1, KS 42-1, KS 40-1 burner, and KS 50-1 (Pro-8, 1/8 DIN) serve ovens, extruders, and burners. Universal inputs handle TC, Pt100, mV, V, and mA across 3 outputs. BluePort® and BlueControl® speed up setup and module swaps.

  • On/off, PID & 3-point stepping
  • Heater current & remote setpoint
  • 3 outputs: relay, SSR, mA/V
  • KS 50-1 (Pro-8, up to 60 C)

Industrial & O2 process controllers KS 90-1, KS 92-1 & KS 94

Industrial controllers KS 90-1 (1/8 DIN), KS 92-1 (Pro-4, 1/4 DIN), and KS 94 handle heat treatment and process lines. High-impedance mV input supports O2 zirconia probes, and profilers run up to 16x16 segments. Options add Modbus RTU, PROFIBUS DP, and plug-in I/O cards.

  • High-impedance O2 probe mV input
  • Profiler up to 16 x 16 segments
  • Optional 3rd universal input
  • RS-422/485 Modbus & PROFIBUS DP

Multi-function automation controllers KS 98-1 & KS 98-2

Multi-function units KS 98-2 (3.5-inch color touch, 1/4 DIN) and legacy KS 98-1 (160x80 LCD) combine PID loops, sequence logic, and logging. ET/KS98 configures up to 20 extra inputs and 26 outputs across 12 slots. Ports cover Ethernet, USB, CANopen, PROFIBUS DP, and PROFINET.

  • 3.5-inch touchscreen / 160x80 LCD
  • Up to 20 extra inputs & 26 outputs
  • 12 internal I/O module slots
  • Ethernet, CANopen, PROFINET, EN 14597

Modular behind-panel multi-loop system KS vario

Behind-panel system KS vario (12.2x120x71.5 mm DIN slice) serves plastics extrusion and PLC machines. It scales from 4 to 30 PID loops (T4/RTD, T4/UTH, T6/RTD, T8/UTH) with heater current monitoring and spring terminals. Fieldbus covers Modbus TCP, PROFIBUS, PROFINET, and CANopen.

  • Scales from 4 to 30 PID loops
  • T4/RTD, T4/UTH, T6/RTD, T8/UTH units
  • Spring terminals & heater current
  • PROFINET, PROFIBUS, Modbus TCP, CAN

Safety temperature limiters STB 55 & STB 50 (SIL2 / EN 14597)

Safety limiters STB 55 (DIN-rail 100x50x110 mm) and STB 50 (1/8 DIN panel) move boilers and thermal plant to safe state on fault. Type-tested to DIN EN 14597 and SIL2 with graphic LCD, warning alarm, and error memory. Inputs take Pt100 or dual J/K/N/S thermocouples up to 1600 C.

  • Approved to DIN EN 14597 & SIL2
  • Pt100 & dual J/K/N/S up to 1600 C
  • 2 alarm relays + 1 analog output
  • 230/115 VAC or 24 VAC/DC supply

Temperature limiters & monitors TB 45 & TB 40-1

Limiters and monitors TB 45 (22.5 mm DIN rail) and panel-mount TB 40-1 (1/8 and 1/4 DIN, replacing TB 40) protect furnaces and steam systems. Both meet EN 14597 TB/TW classes with universal inputs and up to 3 outputs. Setup uses RS-485 Modbus RTU, system bus, or BlueControl®.

  • Meets EN 14597 TB & TW classes
  • 22.5 mm DIN rail (TB 45) / panel (TB 40-1)
  • Dual-TC or second input option
  • RS-485 Modbus RTU & BlueControl®

Rail Line system (KS 45, CI 45, SG 45, RL40), D280-1 & KS 800

The 22.5 mm Rail Line system handles up to 62 hot-swap modules via RL40 couplers (PROFIBUS DP, PROFINET, Modbus TCP, CANopen). It covers KS 45 controllers, CI 45 transmitters, 24-bit SG 45 bridges, and RL42xx-RL46xx I/O. It also covers D280-1 indicators and KS 800 upgrades.

  • Up to 62 hot-swap RL40 modules
  • 24-bit strain-gauge bridge SG 45
  • 5-digit 20 mm indicator D280-1
  • Legacy KS 800 upgrade to KS vario

Plug-in I/O modules, BluePort® cables, terminals & sensors

We source plug-in screw and spring terminal blocks, BluePort® USB-TTL cables, and BlueControl® / BlueLoader tools. Replaceable items include I/O option cards (KS 98-2, KS 90-1, RL40), Pt100, J/K/L/S thermocouples, and P30-2/P40-2 transmitters, plus legacy KS 30, KS 40, KS 94, and Uniflex.

  • BluePort® USB-TTL cable & BlueControl®
  • Plug-in terminals & RL40/KS98-2 I/O
  • J/K/L/S thermocouples, Pt100, P30/P40
  • Migration for KS 30/40/94 & Uniflex

Selecting PMA / West Control Solutions instrumentation by loop & mounting

Selecting PMA instrumentation starts with loop count (single-loop KS 40-1, KS 50-1, KS 90-1, KS 92-1 versus multi-loop KS 98-2 and KS vario up to 30 loops), panel DIN cutout versus DIN-rail footprint, EN 14597 / SIL2 limiter needs, O2 measurement, and fieldbus integration.

Plastics extrusion lines and PLC-integrated machinery benefit from KS vario (4 to 30 zones with spring-clamp terminals and heating current monitoring), while furnaces and combustion processes rely on KS 90-1 high-impedance O2 inputs and KS 98-2 multi-function sequence logic.

Safety limiters DIN EN 14597 / SIL2 and Rail Line fieldbus architecture

For thermal protection of boilers, steam generators, and heat-treatment furnaces, STB 55 (50 mm DIN rail) and STB 50 (1/8 DIN) are type-tested to DIN EN 14597 and SIL2 for 3-wire Pt100 (-100 to +600 C) and dual thermocouples J/K/N/S up to 1600 C, alongside TB 45 and TB 40-1 EN 14597 TB/TW limiters.

The 22.5 mm Rail Line system links up to 62 hot-swappable modules (KS 45, CI 45, 24-bit strain gauge bridge SG 45, and RL42xx-RL46xx I/O) via RL40 couplers for PROFIBUS DP, PROFINET IO, Modbus TCP, and CANopen.

Legacy PMA controller migration and modular accessories

Official replacement paths protect installed machinery bases: KS 30 and KS 40 migrate to KS 50-1, KS 94 and KS 98-1 migrate to KS 98-2 (3.5-inch touchscreen, up to 26 outputs), KS 800 migrates to KS vario, TB 40 to TB 40-1, and Uniflex converters to CI 45.

Plug-in screw and spring-clamp terminal blocks, BluePort® USB-TTL adapters for BlueControl® software, internal option cards, Pt100/thermocouple probes, and P30-2/P40-2 pressure transmitters support long-term equipment availability.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.