Blacoh Industries Fluid Control Equipment and Parts
Selection and export quotation for Blacoh Industries SENTRY pulsation dampeners, SurgeShield vessels, SENTINEL valves, SPILLSTOP systems and spare bladder kits.
AODDampener Series (AOD-10 to AOD-30)
The AODDampener series fits 1 to 3 inch AODD pumps at pressures up to 150 psi (10.3 bar) with automatic air control. A 316 stainless steel housing and PTFE diaphragm damp spikes and cut air use. Spare kits AOD-10-100 to AOD-30-100 simplify service.
- Pump sizes: 1", 1.5", 2", 3"
- 316 SS housing, PTFE diaphragm
- Rating: up to 150 psi (10.3 bar)
- Kits AOD-10-100 to AOD-30-100
SENTRY Pulsation Dampeners and XP Series
The SENTRY XP series handles 2,000 to 15,000 psi using 316L stainless steel housings and ACME threaded caps. Blacoh also builds SENTRY surge suppressors and automatic inlet stabilizers for 1.5 and 2 inch AODD inlets. Replaceable bladders and gas valves support scheduled maintenance.
- XP pressure: 2,000 to 15,000 psi
- 316L SS housing, ACME cap
- Inlet stabilizers: 1.5" and 2"
- Replaceable bladders & O-rings
SurgeShield Surge Vessels and Dampeners
SurgeShield vessels in 15, 25 and 37 gallon (57, 95, 140 L) sizes protect 4 to 6 inch ANSI flange lines up to 250 psig. Housings come in stainless or carbon steel. Field-replaceable PVC F-1, PVC J-22 and Urethane S-1 bladders operate from -29 to 49 °C.
- Volumes: 15, 25, 37 gal (57–140 L)
- 4" to 6" ANSI flange, max 250 psig
- PVC F-1, J-22, Urethane S-1 bladders
- Temp range: -29 to 49 °C (-20 to 120 °F)
SENTRY Hydropneumatic Accumulators
SENTRY hydropneumatic accumulators feature single-body construction with an internal bladder separating fluid from compressed gas. They serve chemical injection, metering pumps, CIP loops and valve actuators. Spare bladders and charging assemblies match ASME-rated units.
- Single-body high-pressure build
- Internal bladder fluid/gas barrier
- Chemical injection, CIP & actuators
- ASME options, spare bladder kits
SENTINEL Valves and Hybrid Valve
SENTINEL back pressure, pressure relief and PVC/CPVC/PVDF degassing valves maintain steady dosing pressure and vent vapors up to 150 psi (10.3 bar). The patented Hybrid Valve merges dampener and back pressure control. Spare diaphragms, springs and seats support valve overhaul.
- Back pressure & relief protection
- Degassing valves: 0.5", 150 psi max
- Patented Hybrid Valve combination
- Replacement diaphragms & springs
SPILLSTOP and SpillGuard Leak Containment
SPILLSTOP and SpillGuard pneumatic units mount on AODD pump exhausts for 1/2 to 2 inch and larger pumps. When a diaphragm fails, the chamber captures leaked fluid and a float cuts pump air automatically. Optional alarm whistles, SCADA switches and seal kits are serviced as spares.
- 100% pneumatic operation, no power
- SpillGuard for 1/2"–2" AODD pumps
- Float-actuated pump air shutoff
- Optional alarm & SCADA switch kits
SENTINEL Seals, Columns and Injection Quills
SENTINEL diaphragm seals in CPVC, PP, PVDF, Alloy 20 and stainless steel protect gauges within +/-2% accuracy up to 1000 psi (68.9 bar). Calibration columns (100 to 20,000 ml) and 0.5 to 1 inch NPT injection quills complete dosing skids. PTFE/EPDM seals, check disks and O-rings are serviceable.
- Gauge guards up to 1000 psi metal
- PVC & glass columns: 100–20,000 ml
- Quills 0.5"–1" NPT, spring check
- EPDM/PTFE bladders & Viton O-rings
SurgeWave Defender Transient Monitoring
SurgeWave Defender captures pipeline pressure spikes and water hammer at 100x/sec (steady state 1x/sec) across two hardwired transducer inputs. Powered at 500 mA and 12 VDC, it uploads event data via cellular cloud telemetry. Replacement transducers, cables and power adapters are supported.
- 100x/sec transient, 1x/sec steady
- 2 hardwired transducer inputs
- 500 mA @ 12 VDC, cellular cloud
- Spare transducers, cables, antennas
Selecting Blacoh Industries Dampeners and Vessels by Pump Type
Sizing a SENTRY, AODDampener or SurgeShield unit starts with the positive displacement pump type (AODD, metering, plunger or peristaltic), flow rate, displacement per stroke, and operating plus peak line pressures.
Wetted housings and bladders match process chemistry and temperature: 316L stainless steel, carbon steel, Alloy 20, PP, PVC, CPVC or PVDF paired with PTFE, EPDM, PVC F-1/J-22 or Urethane S-1 elastomers.
Integrating SENTINEL Valves, SPILLSTOP and Instrumentation
Dosing and transfer skids pair discharge dampeners with SENTINEL back pressure, pressure relief and degassing valves—or a patented Hybrid Valve—alongside SENTRY inlet stabilizers on suction lines to prevent cavitation.
To safeguard operators and gauges, Blacoh systems add pneumatic SPILLSTOP diaphragm-failure shutoff units, SENTINEL diaphragm seals, calibration columns, injection quills and SurgeWave Defender transient monitors.
Blacoh Industries and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Blacoh Industries and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Totton Pumps
- Equipment and parts for Edwards Vacuum / Edwards Limited
- Equipment and parts for Schlick / Düsen-Schlick
- Equipment and parts for Torus Pneumatika
Documents and sources
- Blacoh Industries — official manufacturer website (SENTRY XP, stabilizers, SpillGuard)
- Blacoh AODDampener — specifications and AOD-10-100..AOD-30-100 spare kits
- Blacoh SurgeShield — 15, 25 and 37 gallon surge vessel specifications
- Blacoh SENTRY Accumulators — high-pressure hydropneumatic accumulators
- Blacoh product lineup — SPILLSTOP, SENTINEL valves and Hybrid Valve
- SENTINEL degassing valves — PVC, CPVC, PVDF specs up to 150 psi
- SENTINEL diaphragm seals & gauge guards — specs up to 1000 psi
- SENTINEL calibration columns — ml/min and US GPH dual scale
- SENTINEL injection quills — materials and NPT connection options
- SurgeWave Defender transient monitoring — 100x/sec event recording
- Principles of operation — SENTRY dampeners and SENTINEL valves