Deben In-Situ Testing Stages, Coolstages, and SEM Detectors
Engineering selection of Deben UK Microtest tensile and compression stages (2 N–20 kN), Peltier Coolstages, X-ray CT modules, and Centaurus or ARM2 detectors for SEM, EBSD, and µXCT systems.
Microtest MT200, MT200P and MT1000 (2–1000 N)
Compact tensile and bending stages for polymers, fibers, films, and soft tissues in SEM, AFM, and XRD. Dual leadscrews keep specimens up to 50×15×10 mm centered over 10–20 mm travel at 2–1000 N. Spares include loadcells, bending jaws, optical encoders, and bearings.
- Load range: 2 N to 1000 N (MT200 / MT1000)
- Extensometer resolution: 300 nm
- Linearity: ±1% FS, accuracy ±0.5%
- Spares: loadcells, fiber/bend jaws, leadscrews
Microtest MT2000, MT5000 and Dual-Screw DL (up to 5 kN)
High-load stages for metals, ceramics, and composites under SEM, XRD, and transmission workflows (MT2000DL, MT5000DL). Interchangeable 150–5000 N cells handle specimens up to 67×20×10 mm at 0.2–2.0 mm/min. Spares cover loadcells, dual screws, bearings, and motors.
- Loadcells: 150 N to 5000 N interchangeable
- Extensometer resolution: 3 µm
- Max specimen: 67×20×10 mm, 10/20 mm travel
- Spares: 5 kN cells, dual screws, bearings
EBSD Stages MT2000/5000 ER/EH and Biaxial MT200BA
In-situ EBSD stages (MT2000ER/EH, MT5000ER/EH) pair continuous 5 kN load and 1000 °C heating with clear 70° line of sight, while biaxial MT200BA (200 N) keeps a 30×30 mm centre fixed. Spares cover 70° jaws, water-cooled heaters, and 100 nm optical extensometers.
- EBSD: 70° tilt jaws, 5 kN continuous, 1000 °C
- Dual optical extensometers: 100 nm resolution
- Biaxial MT200BA: 200 N, 30 mm travel, 30×30 mm
- Spares: 70° jaws, heater blocks, optic sensors
SEM Coolstage Series and Variable-Temp MT200VT–MT5000VT
Peltier Standard Coolstage (-25 °C to +50 °C) and Ultra Coolstage (-50 °C to +50 °C) with 0.1 °C readout prevent sublimation in hydrated biological specimens. MT200VT–MT5000VT add -20 °C to +160 °C control under load. Spares include Peltier stacks, flanges, and chillers.
- Coolstage: -25…+50 °C (Standard) / -50…+50 °C (Ultra)
- Accuracy ±1.5 °C, display resolution 0.1 °C
- MT200VT–MT5000VT: mechanical load at -20…+160 °C
- Spares: Peltier modules, vacuum flanges, chillers
X-ray CT and Synchrotron Stages (CT500, CT5000, OF20kN)
Low-attenuation stages CT500, CT5000RT/TEC/H250 (+250 °C), CT160 (-20…+160 °C), CT350 (+350 °C), and 20 kN OF20kN (100 Nm torsion) serve µXCT and beamlines. ULTEM and 67 mm glassy carbon tubes preserve transmission. Spares include tubes, loadcell kits, and rotary adaptors.
- CT load range: 500 N up to 20 kN (OF20kN + 100 Nm)
- Thermal CT stages: CT160 (-20…+160 °C), CT350 (+350 °C)
- Support tubes: ULTEM & 67 mm glassy carbon
- Spares: X-ray tubes, loadcell kits, rotary adaptors
Centaurus Cathodoluminescence (CL) and BSE Detector
Scintillation detector for geology and semiconductors on tungsten and FEG SEMs in HV and LV modes. Captures 185–850 nm CL (opt. 400–1200 nm) and converts to 300–650 nm BSE via exchangeable mirrored, phosphor, or YAG tips. Spares cover tips, PMTs, and bellows drives.
- CL spectral range: 185–850 nm (opt. 400–1200 nm)
- BSE mode: 300–650 nm phosphor or YAG crystal tip
- Low-kV sensitivity in high and low vacuum
- Spares: CL/BSE tips, PMTs, bellows-sealed drives
ARM2 BSE and ARM2 STEM Solid-State Detectors (Gen5)
Modular Gen5 solid-state detectors on motorised ARM2 (<20 µm alignment, 8,000,000:1 gain, <1–30 kV) fit 90° SEM ports. BSE uses 10/14/18 mm 4-quadrant or 26 mm annular diodes; STEM combines 4 DF + BF diodes and a 12-grid holder. Spares cover diodes, holders, and boards.
- Imaging range: <1 kV to 30 kV, 8,000,000:1 gain
- ARM2 BSE: 10/14/18 mm 4-quadrant & 26 mm diodes
- ARM2 STEM: 4-element DF + BF, 12×3 mm grid holder
- Spares: diode assemblies, 12-grid holders, Gen5 boards
SEM Chamberscope, Beam Blankers and Stage Controllers
In-chamber IR Chamberscope cameras (monitor or USB, single/dual view, exchangeable lenses, X-ray shielded) prevent sample collisions with detectors and lenses. Portfolio includes beam blankers and Microtest electronics. Spares cover lenses, IR rings, cables, and boxes.
- Chamberscope: Monitor or USB, single/dual camera
- Illumination: adjustable IR LED, X-ray shielded
- Optics: user-interchangeable wide/narrow lenses
- Spares: lenses, IR rings, control units, vacuum cables
Selecting Microtest, EBSD, and X-ray CT In-Situ Stages
Deben Microtest MT200, MT1000, MT2000, and MT5000 stages combine dual symmetrical leadscrews with interchangeable loadcells from 2 N to 5000 N and optical encoders for in-situ SEM, XRD, AFM, and optical testing. Symmetrical opposing jaw motion keeps the region of interest centred during deformation.
Dedicated EBSD stages (MT2000ER/EH, MT5000ER/EH) provide unobstructed 70° tilt geometry, 100 nm dual optical extensometers, and optional 1000 °C water-cooled heating, while X-ray CT models scale from compact CT500/CT5000 stages with ULTEM or glassy carbon tubes up to the 20 kN open-frame OF20kN with 100 Nm torsion.
Thermal Control Stages for SEM and X-ray Tomography
Peltier-driven Standard Coolstage (-25 °C to +50 °C) and Ultra Coolstage (-50 °C to +50 °C at high vacuum) match sample temperature to chamber pressure (85 Pa at -25 °C, 300 Pa at -9.5 °C) to prevent dehydration in biological and soft materials.
For X-ray CT and synchrotron beamlines, CT160/CT160+ covers -20 °C to +160 °C on 7 mm or 15 mm platens, and CT350 delivers ambient to +350 °C heating at up to 10 °C/min with ±0.2 °C stability.
Centaurus CL/BSE, ARM2 Detectors, and Chamberscope
Centaurus operates as a panchromatic cathodoluminescence detector (185–850 nm, optional 400–1200 nm) and converts to BSE (300–650 nm) by swapping its mirrored tip for a phosphor or YAG tip, with user-exchangeable PMTs and optional bellows-sealed motorised insertion.
Modular Gen5 solid-state detectors on the motorised ARM2 interface (<20 µm alignment, 8,000,000:1 gain from <1 kV to 30 kV) cover BSE (10/14/18 mm four-quadrant or 26 mm annular) and STEM (4-element DF + BF, 12-grid holder), while IR-illuminated Chamberscope cameras protect in-chamber hardware from collisions.
Deben and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Deben and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Bentham Instruments
- Equipment and parts for FemtoTools
- Equipment and parts for PicoQuant
- Equipment and parts for SPEAG
Documents and sources
- About Deben UK Ltd — heritage since 1986, force and temperature ranges
- Microtest MT200 — 2–200 N tensile/compression stage and 300 nm extensometer
- Microtest MT2000VT — 150–2000 N variable temperature stage (-20°C to +160°C)
- Microtest MT5000 — 5 kN tensile and compression stage for SEM, XRD and AFM
- Microtest MT5000EH — 5 kN EBSD stage with 70° tilt jaws and 1000°C heating
- Microtest MT200BA — 200 N bi-axial tensile/compression stage (30x30 mm centre)
- CT160 / CT160+ — Peltier temperature control stage for X-ray CT (-20°C to +160°C)
- CT350 — X-ray CT heating stage up to +350°C at atmospheric pressure
- CT5000TEC ENV — 5 kN environmental X-ray CT stage with glassy carbon tube
- X-ray CT & synchrotron open frame stages — heavy load OF20kN (20 kN)
- Centaurus — panchromatic CL (185–850 nm) and convertible BSE detector
- ARM2 BSE — motorised solid-state Gen5 backscattered electron detector
- ARM2 STEM — solid-state Gen5 BF/DF STEM detector with 12-grid holder
- Standard Coolstage — SEM Peltier stage (-25°C to +50°C) and sublimation control
- Deben tensile & compression stages portfolio — Microtest MT200–MT5000 and CT5000H250 (+250°C)
- Ultra Coolstage — SEM Peltier heating/cooling stage (-50°C to +50°C)
- SEM Chamberscope — IR LED in-chamber camera (monitor or USB, X-ray shielded)