Bentham Instruments (Bentham) — Spectroradiometers, Monochromators & Optical Systems
Export sourcing of Bentham Instruments (Bentham) optical metrology systems: TMc/TMS/DMc/DTMS monochromators, IDR/ISR spectroradiometers, PVE300 EQE/IQE and UMS300 setups, UV-IR detectors, 400 series electronics, and calibration standards.
Single and Double Monochromators TMc, TMS, DMc and DTMS
Single models TMc150/TMc300/TMS300 (150-300 mm) and double DMc150/DTMc300/DTMS300 (300-600 mm) span UV-Vis-IR. Configs support 2-3 grating turrets, motorised slits, and order-sorting filters. We select gratings and slits for Bentham Instruments (Bentham) units.
- Focal length: 150 / 300 / 600 mm
- Dual or triple grating turret
- Coatings: Al, Ag, protected Au
- Motorised or fixed slits
Integrated Spectroradiometers IDR, ISR and Source Systems
IDR150 (300 mm), IDR300 (600 mm), and ISR300 (300 mm) embed picoammeters and HV supplies controlled via USB. Enviro150/300, IDR300-PSL, DVC150, and PTCal150 handle solar, display, and safety tasks. We source Bentham Instruments (Bentham) electronics and modules.
- Integrated picoammeter & HV
- Single USB control interface
- Safety IDR300-PSL & ISR300-PSL
- Outdoor Enviro150 / Enviro300
Photovoltaic EQE/IQE and Detector Evaluation Systems PVE300, LuxCal250, PCS300
PVE300 measures EQE (IPCE) and IQE across 300-2500 nm under IEC 60904-8:2014 using a dual Xenon-QTH source and USB 2.0. LuxCal250, PCS300 (ISO/CIE 19476:2014), and ULS300 (250 W QTH) test detectors. We provide Bentham Instruments (Bentham) spares.
- PVE300 range: 300-2500 nm
- Dual Xenon + QTH illuminator
- IEC 60904-8 / ISO 19476:2014
- ULS300 300 mm 250 W sphere
Material Spectrophotometers UMS300, Goniometers and Tuneable Sources
UMS300 integrates a breadboard, tuneable source, goniometer, and sphere; HUD300 and BPC300-C test layered optics and lenses. TLS120Xe (280-1100 nm), FTMc100-LDS, and FCH homogeniser (U2 >= 98%) deliver uniform illumination for Bentham Instruments (Bentham) setups.
- UMS300 sphere & goniometer
- TLS120Xe span: 280-1100 nm
- FCH field: 60x60 / 120x120 mm
- HUD300 & BPC300-C platforms
UV-Vis-IR Photodetectors (DH_Si, DH_50, MCT) and Entrance Optics
Detectors cover PMTs DH_3/DH_30 (200-850 nm) and cooled DH_50 (200-930 nm), UV-Si DH_Si (200-1100 nm), Ge, extended InGaAs DH_IGa-Ex-3_TE (900-2550 nm), InSb, and MCT DH-MCT12 (2-12 um). Entrance optics D7, D8, IS75-Env, and TEL301 fit Bentham Instruments (Bentham) systems.
- PMTs S20 / cooled 200-930 nm
- DH_Si / Ge / InGaAs to 2550 nm
- Cryo InSb & MCT to 12 um
- Optics: D7, D8, IS75-Env, TEL301
400 Series Detection Electronics, Calibration Standards and BenWin+
The 417 mainframe houses 487 picoammeters, 496 DSP lock-in amplifiers, 218M choppers, and 215 HV supplies, alongside ORM400 and CPS50 TEC controllers. Standards CL-Hg, CL6, CL7, SRS12, DRS-Cal, and BenWin+/BenDev software support Bentham Instruments (Bentham) metrology.
- 417 rack: 487, 496, 215, 218M
- Standalone ORM400 & 418F
- Lamps CL-Hg, CL6, CL7, SRS12
- BenWin+ & Python SCPI BenDev
Selecting Bentham Instruments (Bentham) Monochromators and Spectroradiometers
UK manufacturer Bentham Instruments builds configurable Czerny-Turner monochromators spanning 150 mm single models (TMc150, TMc300, TMS300) to 600 mm double systems (DMc150, DTMc300, DTMS300) with dual or triple grating turrets, aluminium/silver/gold mirror coatings, motorised slits, and order-sorting filters.
Integrated IDR150, IDR300, and ISR300 units embed picoammeters and high-voltage supplies over USB, while the 417 modular mainframe accepts the 487 dual-channel picoammeter, 496 DSP lock-in amplifier, 218M optical chopper, and CPS50 TEC controllers.
Turnkey Systems PVE300, UMS300 and Calibration Traceability
The PVE300 system combines a dual Xenon and quartz tungsten halogen source with a single monochromator (300-2500 nm) to measure EQE (IPCE), IQE, reflectance, and transmittance of single- and multi-junction PV devices under IEC 60904-8:2014 and IEC 60904-8-1:2017.
For optical materials and light sources, UMS300 pairs a tuneable source with a goniometer and integrating sphere, IDR300-PSL evaluates photobiological safety, and traceable standards CL-Hg, CL6, CL7, SRS12, and DRS-Cal support calibration via BenWin+ and Python BenDev.
Bentham Instruments and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Bentham Instruments and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for FemtoTools
- Equipment and parts for SPEAG
- Equipment and parts for PicoQuant
- Equipment and parts for Nanosurf
Documents and sources
- Bentham Instruments — Official Manufacturer Website
- Bentham — Monochromators TMc, TMS, DMc, DTMS, IDR & ISR
- Bentham — Detector Evaluation Systems
- Bentham PVE300 — Photovoltaic EQE (IPCE) and IQE Solution
- Bentham — Source Characterisation Systems
- Bentham — UV-Vis-IR Detectors Portfolio
- Bentham — 400 Series Detection Electronics
- Bentham — Traceable Calibration Standards
- Bentham — Entrance Optics & Integrating Spheres
- Bentham — BenWin+ & BenDev Software Suite
- Bentham — Optical Metrology Systems
- Bentham — Optical Metrology Components