Bentham Instruments (Bentham) — Spectroradiometers, Monochromators & Optical Systems

Export sourcing of Bentham Instruments (Bentham) optical metrology systems: TMc/TMS/DMc/DTMS monochromators, IDR/ISR spectroradiometers, PVE300 EQE/IQE and UMS300 setups, UV-IR detectors, 400 series electronics, and calibration standards.

Single and Double Monochromators TMc, TMS, DMc and DTMS

Single models TMc150/TMc300/TMS300 (150-300 mm) and double DMc150/DTMc300/DTMS300 (300-600 mm) span UV-Vis-IR. Configs support 2-3 grating turrets, motorised slits, and order-sorting filters. We select gratings and slits for Bentham Instruments (Bentham) units.

  • Focal length: 150 / 300 / 600 mm
  • Dual or triple grating turret
  • Coatings: Al, Ag, protected Au
  • Motorised or fixed slits

Integrated Spectroradiometers IDR, ISR and Source Systems

IDR150 (300 mm), IDR300 (600 mm), and ISR300 (300 mm) embed picoammeters and HV supplies controlled via USB. Enviro150/300, IDR300-PSL, DVC150, and PTCal150 handle solar, display, and safety tasks. We source Bentham Instruments (Bentham) electronics and modules.

  • Integrated picoammeter & HV
  • Single USB control interface
  • Safety IDR300-PSL & ISR300-PSL
  • Outdoor Enviro150 / Enviro300

Photovoltaic EQE/IQE and Detector Evaluation Systems PVE300, LuxCal250, PCS300

PVE300 measures EQE (IPCE) and IQE across 300-2500 nm under IEC 60904-8:2014 using a dual Xenon-QTH source and USB 2.0. LuxCal250, PCS300 (ISO/CIE 19476:2014), and ULS300 (250 W QTH) test detectors. We provide Bentham Instruments (Bentham) spares.

  • PVE300 range: 300-2500 nm
  • Dual Xenon + QTH illuminator
  • IEC 60904-8 / ISO 19476:2014
  • ULS300 300 mm 250 W sphere

Material Spectrophotometers UMS300, Goniometers and Tuneable Sources

UMS300 integrates a breadboard, tuneable source, goniometer, and sphere; HUD300 and BPC300-C test layered optics and lenses. TLS120Xe (280-1100 nm), FTMc100-LDS, and FCH homogeniser (U2 >= 98%) deliver uniform illumination for Bentham Instruments (Bentham) setups.

  • UMS300 sphere & goniometer
  • TLS120Xe span: 280-1100 nm
  • FCH field: 60x60 / 120x120 mm
  • HUD300 & BPC300-C platforms

UV-Vis-IR Photodetectors (DH_Si, DH_50, MCT) and Entrance Optics

Detectors cover PMTs DH_3/DH_30 (200-850 nm) and cooled DH_50 (200-930 nm), UV-Si DH_Si (200-1100 nm), Ge, extended InGaAs DH_IGa-Ex-3_TE (900-2550 nm), InSb, and MCT DH-MCT12 (2-12 um). Entrance optics D7, D8, IS75-Env, and TEL301 fit Bentham Instruments (Bentham) systems.

  • PMTs S20 / cooled 200-930 nm
  • DH_Si / Ge / InGaAs to 2550 nm
  • Cryo InSb & MCT to 12 um
  • Optics: D7, D8, IS75-Env, TEL301

400 Series Detection Electronics, Calibration Standards and BenWin+

The 417 mainframe houses 487 picoammeters, 496 DSP lock-in amplifiers, 218M choppers, and 215 HV supplies, alongside ORM400 and CPS50 TEC controllers. Standards CL-Hg, CL6, CL7, SRS12, DRS-Cal, and BenWin+/BenDev software support Bentham Instruments (Bentham) metrology.

  • 417 rack: 487, 496, 215, 218M
  • Standalone ORM400 & 418F
  • Lamps CL-Hg, CL6, CL7, SRS12
  • BenWin+ & Python SCPI BenDev

Selecting Bentham Instruments (Bentham) Monochromators and Spectroradiometers

UK manufacturer Bentham Instruments builds configurable Czerny-Turner monochromators spanning 150 mm single models (TMc150, TMc300, TMS300) to 600 mm double systems (DMc150, DTMc300, DTMS300) with dual or triple grating turrets, aluminium/silver/gold mirror coatings, motorised slits, and order-sorting filters.

Integrated IDR150, IDR300, and ISR300 units embed picoammeters and high-voltage supplies over USB, while the 417 modular mainframe accepts the 487 dual-channel picoammeter, 496 DSP lock-in amplifier, 218M optical chopper, and CPS50 TEC controllers.

Turnkey Systems PVE300, UMS300 and Calibration Traceability

The PVE300 system combines a dual Xenon and quartz tungsten halogen source with a single monochromator (300-2500 nm) to measure EQE (IPCE), IQE, reflectance, and transmittance of single- and multi-junction PV devices under IEC 60904-8:2014 and IEC 60904-8-1:2017.

For optical materials and light sources, UMS300 pairs a tuneable source with a goniometer and integrating sphere, IDR300-PSL evaluates photobiological safety, and traceable standards CL-Hg, CL6, CL7, SRS12, and DRS-Cal support calibration via BenWin+ and Python BenDev.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.