SPEAG (Schmid & Partner Engineering AG) EM & Antenna Test Systems
SpareX selects Swiss-engineered SPEAG (Schmid & Partner Engineering AG) DASY8, cSAR3D, MAGPy3, DAK, TDS, OH4VNA, EASY6, ICEy, EM phantoms, probes, and SEMCAD X systems matched to your frequency bands and standards.
DASY8 & DASY8 3D Robotic EM Scanning Systems
DASY8 is an 8th-generation robotic EM near-field scanning platform covering 3 kHz to 110 GHz across SAR/APD, mmWave, WPT, and HAC modules. Built on TX2-60L and TX2-90XL robots, it integrates with cSAR3D as DASY8 3D and Sim4Life. Field probes and DAE units are replaceable.
- Frequency span: 3 kHz to 110 GHz across modules
- Robotics: TX2-60L and TX2-90XL platforms
- Modules: SAR/APD, mmWave, WPT, HAC, R&D
- Ecosystem: DASY8 3D integration and Sim4Life
cSAR3D High-Speed Vector Array SAR Systems
cSAR3D captures full 3D SAR distributions at 3 measurements per second in full compliance with IEC 62209-3. Its conformal array of over 1000 sensors is calibrated from 650 MHz to 10 GHz with validation down to 300 MHz. Flat (24 kg) and head (17 kg) phantoms pair with CAMO cameras.
- Throughput: 3 measurements/s, > 1000 sensors
- Frequency: 650 MHz – 10 GHz (val. 300 MHz)
- Phantoms: Flat (24 kg) and Head (17 kg), 3 mm
- Automation: CAMO camera, Python scripting
MAGPy3 Magnetic Amplitude & Gradient Systems
MAGPy3 measures magnetic amplitude and field gradients from 3 kHz to 10 MHz for wireless power transfer (WPT) compliance testing. Offered as a handheld kit or robot-mounted DASY8/6 Module WPT3 with 8H3D+E3D probes, it supports IEC/IEEE 63184 and reduces overestimation by up to 40 dB.
- Frequency range: 3 kHz – 10 MHz near-field/WPT
- Formats: handheld unit and DASY8/6 Module WPT3
- Sensor array: multi-axis 8H3D+E3D probe head
- Standards: IEC/IEEE 63184, ISED RSS-102
DAK, DAK-TL2 & DAKS Dielectric Measurement Kits
The DAK line measures permittivity, conductivity, and loss tangent from 4 MHz to 67 GHz across DAK-R resonators, DAK-TL2 thin-layer probes, and DAKS units. DAK-R characterizes 0.1–3 mm substrates at 10–45 GHz, while DAK-TL2 handles 100 um–10 mm layers and 10–50 ml liquid samples.
- Frequency span: 4 MHz to 67 GHz (DAK-12/3.5/1.2E)
- DAK-R cavity: 10–45 GHz for 0.1–3 mm substrates
- DAK-TL2: 100 um–10 mm thin layers, 10–50 ml
- DAKS units: rigid Copper Mountain R60/R140 VNA
TDS Optical Near-Field Probes & OH4VNA Links
Active optically isolated TDS probes (10 MHz–6 GHz) capture near-field E/H amplitude and phase in time and frequency domains, with rfof1p extending 100 kHz–10 GHz. The bi-directional OH4VNA RF-over-fiber link measures S11 of small antennas across 500 MHz–6 GHz without cable loading.
- TDS probes: active E/H near-field, 10 MHz–6 GHz
- RFoF links: rfof1p and rfof1p4med, 100 kHz–10 GHz
- OH4VNA: S11 antenna link across 500 MHz – 6 GHz
- Isolation: fully fiber-optic, zero battery needed
EASY6 Acquisition Units & ICEy Near-Field Scanners
EASY6 is a stand-alone multi-channel acquisition system (EASY6-1 and EASY6-2) connecting up to 16 E/H-field, dosimetric, and temperature probes via optical link (DAE + EOF + RU) even inside MRI rooms. ICEy scanners provide micrometer-precision near-field EMI/EMC and mmWave measurements.
- EASY6 capacity: up to 16 E/H, SAR, and T channels
- Hardware chain: EASY6-DAE, EOF fiber, USB EASY6-RU
- ICEy modules: EMC (IEC TS 61967-3) and mmW
- Data output: Sim4Life, MATLAB, and SciPy export
EM Phantoms (CTIA / POPEYE10) & SEMCAD X Software
SPEAG whole- and partial-body phantoms (CTIA sub-3 GHz and mmW lossy silicone, POPEYE10, customized models) span <10 MHz to >100 GHz for OTA, SAR, and proximity testing. SEMCAD X Matterhorn adds 3-D full-wave Antenna, EMC, ELF, uWave, Optics, and HPC simulation tied to Sim4Life.
- Phantom band: <10 MHz to >100 GHz (CTIA OTA/SAR)
- Compounds: lossy silicone Type I (<3 GHz) & II
- Models: POPEYE10 whole-body, head, hand, wrist
- SEMCAD X: Antenna, EMC, ELF, uWave, Optics, HPC
Probes, DAE Units, V&V Sources & Simulating Liquids
SPEAG replaceable components include miniature SAR, E-field, H-field, power density (PD), and temperature probes, mechanical dummy probes, DAE acquisition units, and EOF optical fibers. System check hardware covers V&V validation sources, shorting blocks, and tissue-simulating liquids.
- Probes: SAR, E/H-field, PD, temperature, dummy
- Acquisition: DAE modules, EOF fiber cables, RU
- Validation: V&V SAR/mmWave/WPT dipoles & sources
- Liquids: tissue-simulating liquids and dielectric DB
Selecting SPEAG (Schmid & Partner Engineering AG) Systems by Compliance Task
SPEAG (Schmid & Partner Engineering AG) structures its portfolio around international EM exposure, SAR, and antenna testing standards.
DASY8 serves as the flagship 8th-generation robotic near-field platform spanning 3 kHz to 110 GHz on TX2-60L and TX2-90XL robots with dedicated modules for SAR/APD (4 MHz–10 GHz and 10–45 GHz), mmWave incident power density (6–110 GHz), WPT (3 kHz–4 MHz), HAC (IEEE C63.19-2019), and R&D scripting.
Where high throughput is needed for R&D iterations or production QA, cSAR3D captures full 3D SAR in 3 measurements per second under IEC 62209-3 and combines with DASY8 into DASY8 3D.
WPT Exposure (MAGPy3), Dielectric Spectroscopy (DAK) & Antenna S11
Wireless power transfer systems and strong near-field sources between 3 kHz and 10 MHz are evaluated using MAGPy3 handheld units or robot-mounted DASY8/6 Module WPT3 with 8H3D+E3D probes, meeting IEC/IEEE 63184 Tier 2–4 and reducing overestimation by up to 40 dB.
Material dielectric permittivity and loss tangent across 4 MHz to 67 GHz are measured with DAK single probes (DAK-12, DAK-3.5, DAK-1.2e), DAK-TL2 for 100 um–10 mm thin layers and 10–50 ml liquids, DAK-R split-cylinder resonators (10–45 GHz, IPC TM-650), and DAKS units with Copper Mountain R60/R140 reflectometers.
OH4VNA isolates S11 antenna measurements across 500 MHz–6 GHz over fiber.
Multi-Channel EASY6 Acquisition, EM Phantoms & SEMCAD X Simulation
EASY6 (EASY6-1 and EASY6-2) connects up to 16 E/H-field, dosimetric, and temperature probes via optical link (EASY6-DAE + EASY6-EOF + EASY6-RU) for hostile EM environments and MRI testing, while ICEy scanners automate micrometer-scale EMI/EMC and mmWave near-field mapping.
To complete test setups, SPEAG provides CTIA sub-3 GHz and >3 GHz lossy silicone phantoms, the POPEYE10 whole-body phantom (<10 MHz to >100 GHz), tissue-simulating liquids, V&V verification dipoles, and SEMCAD X Matterhorn 3-D full-wave simulation packages coupled with Sim4Life.
SPEAG and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of SPEAG and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Nanosurf
- Equipment and parts for Neware
- Equipment and parts for Testometric
- Equipment and parts for United Automation
Documents and sources
- SPEAG (Schmid & Partner Engineering AG) official homepage
- SPEAG Systems overview (DASY8, cSAR3D, MAGPy, DAK, TDS)
- DASY8 & DASY8 3D specification — modules from 3 kHz to 110 GHz
- cSAR3D vector array SAR system — specs and IEC 62209-3
- MAGPy3 magnetic amplitude and gradient probe system for WPT
- DAK dielectric spectroscopy overview (4 MHz – 67 GHz)
- Time Domain Sensor (TDS) active near-field probes overview
- OH4VNA RF-over-fiber link for small antenna S11 measurements
- EASY6 multi-channel EM exposure acquisition system
- ICEy reactive near-field scanning system (EMC and mmW)
- SPEAG whole- and partial-body EM phantoms overview
- SPEAG miniature EM and thermal field probes overview
- SEMCAD X Matterhorn 3-D full-wave EM simulation solutions
- SPEAG laboratories services and ISO/IEC 17025 calibration
- SPEAG official Chinese homepage (Schmid & Partner Engineering AG)