KBR Kompensationsanlagenbau / KBR EnergyManagement equipment: PFC systems, harmonic filters, and analyzers

German-engineered reactive power compensation cabinets multicab-R, active and passive mains filters multiwave, Class A analyzers multimess, controllers multicomp, capacitors multicond, and multict current transformers from KBR Schwabach.

PFC systems multicab-R and multimod-R

Regulated power factor correction cabinets multicab-R-S, multicab-R-G, and multicab-R-E up to 500 kvar alongside wall-mounted multicab-R-I and multicab-R-W enclosures. Available with thyristor switches (R-T) and mounting-plate multimod-R units. Key spares: fans, contactors, modules.

  • System rating: up to 500 kvar
  • Enclosures: R-S, R-G, R-E, R-I, R-W
  • Safety: securec monitoring module
  • Options: detuned & fire suppression

Power capacitors multicond and multicab-F

Manufactured in Schwabach, multicond power capacitors and multicab-F fixed capacitor units form the active capacitive stages of KBR compensation cabinets. They operate in both conventional and detuned filter circuits. Serviceable items include capacitor cans, discharge resistors, and bus terminals.

  • Product lines: multicond, multicab-F
  • Use: regulated & fixed PFC steps
  • Testing: stage current & capacitance
  • Wear parts: discharge resistors

Reactive power controllers multicomp D6 / F144

DIN-rail multicomp D6-xxx-7 and panel-mounted multicomp F144 / F144-3Ph controllers manage capacitor step switching and monitor grid stability. Three-phase 3Ph variants track asymmetrical loads across industrial feeders. Replacement scope covers controller units, terminal plugs, and bus boards.

  • Mounting: DIN-rail D6 & panel F144
  • Sensing: 1-phase and 3-phase (3Ph)
  • Service: parameterization & updates
  • Diagnostics: fault memory readout

Filter reactors multiind and thyroswitch

multiind filter circuit reactors prevent harmonic resonance in distribution grids with variable-speed drives. thyroswitch modules plus plug-in multimod-F-S, multimod-F-T, and multimod-SM assemblies enable rapid, wear-free stage switching. Spares include reactors, thyristor bricks, and fans.

  • Chokes: multiind filter reactors
  • Switching: thyroswitch thyristors
  • Plug-in: multimod-F-S / F-T / SM
  • Role: detuned dynamic PFC stages

Mains filters multiwave active and passive

multiwave active, multiwave passive, and multiwave passive HF harmonic filters suppress grid interference and feedback generated by power electronics. They safeguard CNC drives and switchgear stability. Serviceable parts cover power modules, cabinet fans, and air filter mats.

  • Series: active, passive, passive HF
  • Effect: harmonic & feedback suppression
  • Standards: EN 50160 / EN 61000-2-2
  • Spares: power blocks, fans, filter mats

Energy meters multimess and multilog 3

multimess F96 TFT, F144-LED, D6, D4, MID-compliant multicount D5 meters, and Class A power analyzers (D9-PQ, F144-PQ, mobile multilog 3) capture harmonics up to 20 kHz under DIN EN 50160. Replacement parts include F96 interface retrofit kits, multisys gateways, and D4-PS24V 24 V power supplies.

  • Class A PQ: D9-PQ, F144-PQ, multilog 3
  • Bandwidth: harmonics up to 20 kHz
  • Meters: F96 TFT, D6, D4, multicount D5
  • System: multisys gateways & D4-PS24V

Current transformers and Rogowski multict

The multict family covers ASK, CTM7, CTB bushing transformers, KBU split-core sensors, KBR core-balanced, DACT residual current, KSU/SUSK totalizing units, and FASK Rogowski coils. Wideband XCTB, XKBU, and XKBR transducers support measurements up to 20 kHz alongside EASK/ECTB billing models.

  • Bushing & billing: ASK, CTB, EASK
  • Split-core & sum: KBU, KSU / SUSK
  • Rogowski coils: multict FASK
  • Wideband XCTB / XKBU / XKBR: 20 kHz

Load optimization multimax and multisio I/O

multimax D6 and multimax IGW monitor power demand, integrate EV chargers or battery storage, and prevent costly load peaks. multisio D2, D4, and D6 modules feed digital and analog field signals into visual energy software. Replacement parts include I/O blocks, gateways, and securec modules.

  • Peak shaving: multimax D6 & IGW
  • Field I/O: multisio D2 / D4 / D6
  • Software: visual energy (ISO 50001)
  • Cabinet safety: securec & smoke unit

Selecting KBR Kompensationsanlagenbau / KBR EnergyManagement PFC and filtering systems

When specifying turnkey reactive power compensation systems—floor-standing multicab-R-S, multicab-R-G, multicab-R-E up to 500 kvar, dynamic thyristor-switched multicab-R-T, or wall-mounted multicab-R-I and multicab-R-W enclosures—key sizing inputs include nominal bus voltage, target cos phi, load profile dynamics, and harmonic distortion.

For grids with power-electronic drives or converters, detuned capacitor steps with multiind filter reactors or multiwave active/passive mains filters prevent resonance. Cabinets feature temperature-controlled ventilation, the securec safety module, and optional automatic fire suppression.

Energy metering, power quality monitoring, and visual energy integration

Class A analyzers multimess D9-PQ and F144-PQ as well as mobile multilog 3 recorders monitor voltage quality up to 20 kHz in accordance with DIN EN 50160 and DIN EN 61000-2-2.

Paired with multict bushing, split-core, Rogowski (FASK), or 20 kHz wideband XCTB/XKBU current transformers, they establish traceable ISO 50001 metering.

Field signals from multisio D2/D4/D6 modules and peak-shaving controllers multimax D6/IGW connect via KBR eBus or Modbus to visual energy energy data management software.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.