KBR Kompensationsanlagenbau / KBR EnergyManagement equipment: PFC systems, harmonic filters, and analyzers
German-engineered reactive power compensation cabinets multicab-R, active and passive mains filters multiwave, Class A analyzers multimess, controllers multicomp, capacitors multicond, and multict current transformers from KBR Schwabach.
PFC systems multicab-R and multimod-R
Regulated power factor correction cabinets multicab-R-S, multicab-R-G, and multicab-R-E up to 500 kvar alongside wall-mounted multicab-R-I and multicab-R-W enclosures. Available with thyristor switches (R-T) and mounting-plate multimod-R units. Key spares: fans, contactors, modules.
- System rating: up to 500 kvar
- Enclosures: R-S, R-G, R-E, R-I, R-W
- Safety: securec monitoring module
- Options: detuned & fire suppression
Power capacitors multicond and multicab-F
Manufactured in Schwabach, multicond power capacitors and multicab-F fixed capacitor units form the active capacitive stages of KBR compensation cabinets. They operate in both conventional and detuned filter circuits. Serviceable items include capacitor cans, discharge resistors, and bus terminals.
- Product lines: multicond, multicab-F
- Use: regulated & fixed PFC steps
- Testing: stage current & capacitance
- Wear parts: discharge resistors
Reactive power controllers multicomp D6 / F144
DIN-rail multicomp D6-xxx-7 and panel-mounted multicomp F144 / F144-3Ph controllers manage capacitor step switching and monitor grid stability. Three-phase 3Ph variants track asymmetrical loads across industrial feeders. Replacement scope covers controller units, terminal plugs, and bus boards.
- Mounting: DIN-rail D6 & panel F144
- Sensing: 1-phase and 3-phase (3Ph)
- Service: parameterization & updates
- Diagnostics: fault memory readout
Filter reactors multiind and thyroswitch
multiind filter circuit reactors prevent harmonic resonance in distribution grids with variable-speed drives. thyroswitch modules plus plug-in multimod-F-S, multimod-F-T, and multimod-SM assemblies enable rapid, wear-free stage switching. Spares include reactors, thyristor bricks, and fans.
- Chokes: multiind filter reactors
- Switching: thyroswitch thyristors
- Plug-in: multimod-F-S / F-T / SM
- Role: detuned dynamic PFC stages
Mains filters multiwave active and passive
multiwave active, multiwave passive, and multiwave passive HF harmonic filters suppress grid interference and feedback generated by power electronics. They safeguard CNC drives and switchgear stability. Serviceable parts cover power modules, cabinet fans, and air filter mats.
- Series: active, passive, passive HF
- Effect: harmonic & feedback suppression
- Standards: EN 50160 / EN 61000-2-2
- Spares: power blocks, fans, filter mats
Energy meters multimess and multilog 3
multimess F96 TFT, F144-LED, D6, D4, MID-compliant multicount D5 meters, and Class A power analyzers (D9-PQ, F144-PQ, mobile multilog 3) capture harmonics up to 20 kHz under DIN EN 50160. Replacement parts include F96 interface retrofit kits, multisys gateways, and D4-PS24V 24 V power supplies.
- Class A PQ: D9-PQ, F144-PQ, multilog 3
- Bandwidth: harmonics up to 20 kHz
- Meters: F96 TFT, D6, D4, multicount D5
- System: multisys gateways & D4-PS24V
Current transformers and Rogowski multict
The multict family covers ASK, CTM7, CTB bushing transformers, KBU split-core sensors, KBR core-balanced, DACT residual current, KSU/SUSK totalizing units, and FASK Rogowski coils. Wideband XCTB, XKBU, and XKBR transducers support measurements up to 20 kHz alongside EASK/ECTB billing models.
- Bushing & billing: ASK, CTB, EASK
- Split-core & sum: KBU, KSU / SUSK
- Rogowski coils: multict FASK
- Wideband XCTB / XKBU / XKBR: 20 kHz
Load optimization multimax and multisio I/O
multimax D6 and multimax IGW monitor power demand, integrate EV chargers or battery storage, and prevent costly load peaks. multisio D2, D4, and D6 modules feed digital and analog field signals into visual energy software. Replacement parts include I/O blocks, gateways, and securec modules.
- Peak shaving: multimax D6 & IGW
- Field I/O: multisio D2 / D4 / D6
- Software: visual energy (ISO 50001)
- Cabinet safety: securec & smoke unit
Selecting KBR Kompensationsanlagenbau / KBR EnergyManagement PFC and filtering systems
When specifying turnkey reactive power compensation systems—floor-standing multicab-R-S, multicab-R-G, multicab-R-E up to 500 kvar, dynamic thyristor-switched multicab-R-T, or wall-mounted multicab-R-I and multicab-R-W enclosures—key sizing inputs include nominal bus voltage, target cos phi, load profile dynamics, and harmonic distortion.
For grids with power-electronic drives or converters, detuned capacitor steps with multiind filter reactors or multiwave active/passive mains filters prevent resonance. Cabinets feature temperature-controlled ventilation, the securec safety module, and optional automatic fire suppression.
Energy metering, power quality monitoring, and visual energy integration
Class A analyzers multimess D9-PQ and F144-PQ as well as mobile multilog 3 recorders monitor voltage quality up to 20 kHz in accordance with DIN EN 50160 and DIN EN 61000-2-2.
Paired with multict bushing, split-core, Rogowski (FASK), or 20 kHz wideband XCTB/XKBU current transformers, they establish traceable ISO 50001 metering.
Field signals from multisio D2/D4/D6 modules and peak-shaving controllers multimax D6/IGW connect via KBR eBus or Modbus to visual energy energy data management software.
KBR Kompensationsanlagenbau / KBR EnergyManagement and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of KBR Kompensationsanlagenbau / KBR EnergyManagement and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Vivax-Metrotech
- Equipment and parts for PCE Instruments
- Equipment and parts for Radiodetection
- Equipment and parts for UniMeasure
Documents and sources
- KBR EnergyManagement (formerly KBR Kompensationsanlagenbau) — company profile
- Reactive current compensation systems multicab-R and multimod-R
- Compensation components: multicomp, multicond, multiind, thyroswitch
- Energy meters multimess, multicount D5 and multisys accessories
- Class A network analyzers multimess D9-PQ, F144-PQ and multilog 3
- multict current transformers and Rogowski coils
- Active and passive mains filters multiwave for grid optimization
- Maintenance and service procedures for compensation systems and visual energy
- Power quality measurement packages up to 170 kHz and 2 MHz transients