PCE Instruments Measuring Equipment, Borescopes & Scales
Selection and quotation of PCE Instruments (PCE Holding GmbH / PCE Deutschland GmbH) industrial measuring devices, video endoscopes, thickness gauges, data loggers, multimeters, analytical balances, scales and replacement probes.
PCE-VE Video Endoscopes
PCE-VE 320N/330N/340N endoscopes use 1–10 m cables (5.5 mm probe, 2 GB memory), while PCE-VE 350N/360N add 2-way articulation. PCE-VE 1000 (7" LCD) and VE 380N (30 m, 28 mm) inspect pipes and machinery. Replaceable probes, LED heads, batteries and cables are sourced.
- PCE-VE 320N–380N, VE 1000
- Probe dia 3.9–28 mm
- Cable length 1–30 m
- Probes, LED heads, batteries
PCE-CT & PCE-TG Thickness Gauges
PCE-CT 25–28, 40 and 60 gauges check coatings on ferrous (F) and non-ferrous (N) metals up to 5000 µm. Ultrasonic PCE-TG 50–300 measure walls up to 600 mm and 400 °C (TG 110) at 1000–9999 m/s. External F/FN sensors, ultrasonic probes and cables are supplied.
- PCE-CT 25–60, PCE-TG 50–300
- Coatings 0–5000 µm (F/FN)
- Walls up to 600 mm / 400 °C
- F/FN sensors, UT probes
PCE-RT Surface Roughness Testers
Portable PCE-RT 10, 11 and 1200 testers measure Ra, Rz, Rq and Rt via a diamond inductive sensor. Units follow DIN 4762, 4768, 4771 and 4775 standards with internal memory storage. Diamond stylus probes, probe guards, control cards and accumulators are sourced.
- PCE-RT 10 / 11 / 1200
- Parameters Ra, Rz, Rq, Rt
- DIN 4762 / 4768 / 4775
- Diamond probes, control cards
PCE-318 & PCE-322A Sound Level Meters
PCE-999, PCE-318 and PCE-322A meters monitor workplace and plant noise at ±1.5 dB accuracy. PCE-318 measures from 26 dB with analogue output, while PCE-322A adds logging memory and USB. Microphones, windscreens, extension leads and calibrators are supplied.
- PCE-999 / 318 / 322A / SLT
- From 26 dB, ±1.5 dB accuracy
- Analogue out & USB logging
- Microphones, cables, screens
PCE-HT & PCE-T390 Data Loggers
PCE-HT 71N, PCE-TD 60 (-40 to +85 °C, USB), PCE-THB 40 and 12-channel PCE-T 1200 (Type K, SD) record climate and temperature. PCE-VM 31, VD 3 and HPT 1 (Pt100) track vibration and heat. External probes, Type K sensors, mounts and USB leads are sourced.
- PCE-HT 71N, TD 60, T390, T1200
- -40 to +85 °C, SD / USB
- Up to 12 ch, Pt100 & Type K
- External probes, mounts, cables
PCE-DM & PCE-UT Digital Multimeters
PCE-DM 12 (600 V), DM 22 (1000 V CAT III, RS-232), DM 32 (20 A, +1000 °C) and TRMS PCE-UT 71D up to 100 kHz support electrical commissioning. Compact PCE-PDM 1 and TT 1 testers handle quick checks. Test leads, thermocouples, fuses and RS-232 leads are supplied.
- PCE-DM 12/22/32, UT 71D
- Up to 1000 V CAT III, 20 A
- TRMS to 100 kHz, RS-232
- Test leads, probes, fuses
PCE-AB & PCE-LS Laboratory Balances
PCE-AB, AB-C and ABZ 100C/200C analytical balances feature 0.1 mg readability, internal adjustment and RS-232. PCE-LS/LSM (up to 6000 g), LSZ 200C (up to 20,000 g/m²) and HB serve lab dosing. Replacement pans, wind screens, OIML weights and adaptors are sourced.
- PCE-AB / ABZ / LS / LSZ / HB
- Readability from 0.1 mg
- Capacity up to 6000 g, RS-232
- Pans, wind screens, weights
PCE-PB & PCE-TSS Industrial Scales
PCE-PB (60/150 kg, USB), stainless IP 67 PCE-TSS (up to 15 kg), verified M III PCE-ESM (25 kg) and counting PCE-PCS (6/30 kg, RS-232) run on batteries or 240/12 V mains. Replacement load cells, weight indicators, battery packs and data cables are supplied.
- PCE-PB / TSS / ESM / PCS
- Capacity up to 150 kg, IP 67
- Battery & 240 V / 12 V power
- Load cells, indicators, batteries
Selecting PCE Instruments by Range, Protection and Interface
Selecting PCE Instruments equipment requires matching sensor principle and range (0–5000 µm coating, up to 600 mm wall thickness, 0.1 mg analytical to 150 kg platform scales), IP 67 protection, RS-232 or USB output, and ISO or DAkkS calibration documents.
For automated lines and fixed monitoring, the portfolio covers panel indicators, PID controllers, signal conditioners (4–20 mA, RS-485, Profibus DP) and multi-channel SD-card data loggers.
Factory and Accredited Calibration Protocols
Per PCE Holding GmbH and PCE Deutschland GmbH documentation, instruments leave the factory pre-adjusted and can be ordered with ISO 9000, DAkkS, UKAS or NIST calibration documentation at customer-specified test points.
For verifiable Class II/III balances, gravity zone adjustment by installation postal area and OIML calibration weights are specified in the quotation.
PCE Instruments and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of PCE Instruments and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Vögtlin Instruments
- Equipment and parts for COSMO Instruments
- Equipment and parts for Velleman Instruments
- Equipment and parts for Winters Instruments
Documents and sources
- PCE Holding GmbH — Corporate Information and Group Structure
- PCE Instruments — Global Subsidiaries and Product Overview
- PCE Instruments — Measuring Instruments Portfolio
- PCE Instruments — Calibration Service (ISO 9000, DAkkS, UKAS, NIST)
- PCE-VE & PCE-RVE Industrial Endoscopes Specifications
- PCE-CT Coating & PCE-TG Ultrasonic Thickness Gauges
- PCE-RT 10 / 11 / 1200 Surface Roughness Testers
- PCE-999, PCE-318 & PCE-322A Sound Level Meters
- PCE-HT, PCE-TD, PCE-T & PCE-VM/VD Data Loggers
- PCE-DM & PCE-UT Digital Multimeters Specifications
- PCE-AB, PCE-ABZ & PCE-LS Analytical Balances
- PCE-PB, PCE-TSS, PCE-ESM & PCE-PCS Industrial Scales
- PCE Control Systems, Panel Meters & Signal Converters