LaserPoint laser power and energy meters
Technical selection of LaserPoint equipment: A and W thermal sensors, the W-12K calorimeter, Blink FR and HS sensors, Pulse Controller, Fit, Cronos and EXTREME probes, photodiodes and PLUS 2, PC-Link, HSM-1000 meters.
Low-power thermal sensors
Low-power thermal heads are rated up to 40 W, up to 200 W intermittent, with convection cooling. The A-02-D12-BBF measures 0.1 to 200 mW over 0.19-25 µm. The A-40/200-D60-HPB with a 60 mm aperture measures energy from 250 mJ to 200 J.
- Power up to 40 W
- A-02-D12-BBF: 0.19-25 µm
- A-40/200-D60-HPB: up to 200 J
- Convection cooling
Medium-power thermal sensors
Models from A-200 to A-600 are fan cooled and the W-200 and W-600 models are water cooled; the limit is 600 W continuous and 800 W intermittent. The A-600-D40-HPB measures 0.5-600 W and 1-800 J. The W-600-D70-SHC with SHC coating has a 70 mm aperture.
- Power up to 600 W
- Up to 800 W intermittent
- W-600-D70-SHC: 70 mm aperture
- Fan or water cooling
High-power sensors and calorimeter
Water-cooled heads are rated up to 6 kW continuous and up to 9 kW intermittent: the W-6000-D55-SHC measures 15 W to 6 kW with a 55 mm aperture. The W-3000-D55-SHC weighs 4.2 kg. The W-12K-D55-SHC-U calorimeter measures 100 W to 12 kW without defocusing optics.
- W-6000-D55-SHC: up to 6 kW
- W-12K calorimeter: up to 12 kW
- 55 mm aperture on W-6000, W-12K
- W series: water cooling
Sensors for pulsed lasers
BB, UVA and UVC sensors measure power and single-shot energy with apertures up to 40 mm. The 20-BB-D40 covers 0.4-5.2 µm and 100 mJ to 20 J, the 10-UVC-D25 covers UV at 0.19-0.25 µm. For high energy density there are the A-40-D33-DIF and A-200-D12-SHC-L.
- Aperture up to 40 mm
- 10-UVC-D25: 0.19-0.25 µm
- 20-BB-D40: energy up to 20 J
- A-40-D33-DIF: energy up to 60 J
Blink FR and Blink HS fast thermal sensors
Blink HS measures the energy of each pulse at repetition rates up to 1 MHz: the BM-A-5W-14-T covers 1 mW to 5 W and the water-cooled BM-W-50W-10-B goes up to 50 W. Blink FR has a natural response time of 90 ms typical; the BL-W-100W-12-A measures 100 mW to 100 W.
- Blink HS: up to 1 MHz
- Blink FR: 90 ms typical response
- BM-W-50W-10-B: up to 50 W
- BL-W-100W-12-A: up to 100 W
HSM-1000 meter and Pulse Controller
The HSM-1000 connects Blink HS sensors to a PC over Ethernet: 500 Msamples/s, 14-bit ADC, pulse repetition range 1 kHz to 1 MHz. Pulse Controller with the HSM-1000-PC works at up to 0.8 MHz and flags every missing pulse and every pulse below a user-set energy threshold.
- ADC: 500 Msamples/s
- HSM-1000: 1 kHz to 1 MHz
- Pulse Controller: up to 0.8 MHz
- SMA Trigger IN and OUT
Fit, Cronos and EXTREME power probes
Fit probes are conduction cooled: the Fit-50 covers 0.5-50 W and the Fit-500 covers 5-500 W. The Cronos LP10 measures 200 W to 10 kW with a 65 mm aperture. The EXTREME-40 for 1070 nm measures 500 W to 40 kW without water cooling and comes with a beam positioning target.
- Fit-500: up to 500 W
- Cronos LP10: up to 10 kW
- EXTREME-40: up to 40 kW
- EXTREME-40: 1070 nm
PD photodiodes and PLUS 2, PC-Link meters
The PD-50-D9-UV and PD-500-D9-VIS are silicon photodiodes, the PD-50-D9-IR is germanium for 800-1800 nm, aperture 9.5 mm. The 380 g handheld PLUS 2 works with thermal sensors, FIT-H probes, EXTREME, photodiodes and Blink FR. The 106 g PC-Link connects thermal heads to a PC.
- PD-50-D9-UV: 200-1100 nm
- PD-500-D9-VIS: up to 500 mW
- PLUS 2: 380 g
- PC-Link: 106 g
Choosing a laser power meter
LASERPOINT SRL is an independent company based in Vimodrone (province of Milan, Italy) with more than 30 years of developing and manufacturing laser measurement instruments: laser power and energy meters up to multi-kilowatt levels.
Sensors are chosen by power: low-power thermal heads are rated up to 40 W (up to 200 W intermittent), medium-power heads up to 600 W (up to 800 W intermittent), water-cooled heads up to 6 kW (up to 9 kW intermittent).
The W-12K-D55-SHC-U calorimeter measures 100 W to 12 kW, and the EXTREME-40 probe for 1070 nm measures 500 W to 40 kW without water cooling.
Pulsed and ultrafast lasers
For pulsed lasers the range includes the 20-BB-D40 (0.4-5.2 µm, 100 mJ to 20 J) and the 10-UVC-D25 (0.19-0.25 µm); for high energy density there are the A-40-D33-DIF and A-200-D12-SHC-L.
Blink HS measures the energy of each pulse at repetition rates up to 1 MHz and works with the HSM-1000 meter (500 Msamples/s ADC, Ethernet link). Pulse Controller works at up to 0.8 MHz and flags missing pulses and pulses below the energy threshold.
Blink FR has a natural response time of 90 ms typical.
Meters and photodiodes
The 380 g handheld PLUS 2 works with thermal sensors, FIT-H probes, EXTREME, photodiodes and Blink FR; the 106 g PC-Link turns a PC into a meter for thermal heads and OEM FIT-H probes. Thermal sensors come with a DB15 connector or with USB and RS-232.
The PD-50-D9-UV and PD-500-D9-VIS are silicon photodiodes, the PD-50-D9-IR is germanium for 800-1800 nm; the PD-500-D9-VIS measures up to 500 mW. Fiber adapters SMA, ST, FC, LC and SC are available for the photodiodes.
LaserPoint and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of LaserPoint and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for NPI Lasers
- Equipment and parts for EKSPLA
- Equipment and parts for Wasatch Photonics
- Equipment and parts for BWT Beijing
Documents and sources
- About LaserPoint — company profile
- Thermal sensors — series overview
- Low power thermal sensors — model table
- Medium power thermal sensors — model table
- High power thermal sensors — model table
- W-3000-D55-SHC sensor — specifications
- W-12K-D55-SHC-U calorimeter — specifications
- Sensors for pulsed lasers — model table
- High energy density sensors — model table
- Blink HS sensors — model table
- Blink FR sensors — model table
- Pulse Controller — system overview
- HSM-1000 meter — specifications
- Fit probes — model table
- Cronos probes — model table
- EXTREME probes — model table
- Photodiode sensors — model table
- PLUS 2 meter — specifications
- PC-Link meter — specifications
- Calibrations — recalibration procedure