UNITERM SRL (UNITERM S.R.L. / OTAM) Custom Heat Exchangers & Air Coolers

Custom-made UNITERM SRL gas-gas and gas-fluid heat exchangers: 1.1–1.5 air condensers, MDTM -53 °C lube oil coolers and 330 barg gas intercoolers, 160 barg / 400 °C air & gas heaters, 116 barg economizers and finned tube coils.

Air Condensers 1.1–1.2

Series 1.1 steam air condensers and 1.2 vapour and solvent condensers operate under positive pressure. Built for power boilers, cogeneration, waste incinerators, chemical and pulp plants. Replaceable parts cover finned tube bundles, headers, gaskets and fan assemblies.

  • Series: 1.1 (steam), 1.2 (vapour & solvents)
  • Duty: positive-pressure air condensation
  • Sectors: power, cogeneration, chemical, pulp
  • Spares: finned bundles, headers, seals, fans

Liquid & Lube Oil Air Coolers 1.3–1.4

Series 1.3 liquid coolers and 1.4 lube oil air coolers serve gas turbines, compressors, pumps and motors. Proven Arctic builds operate down to MDTM -53 °C on Russian gas plants. Key spare parts include finned tube bundles, return bends, manifolds and fan impellers.

  • Series: 1.3 (heavy-duty liquid), 1.4 (lube oil)
  • Verified cold-climate build: MDTM -53 °C
  • Equipment: gas turbines, compressors, pumps
  • Spares: tube bundles, bends, manifolds, fans

Compressed Gas Intercoolers 1.5

Series 1.5 compressed gas air coolers and intercoolers operate on gas process skids and CNG refueling stations. Verified natural gas builds reach 330 barg design pressure. Replaceable parts include high-pressure bundles, flanged headers, gaskets and louver actuators.

  • Series: 1.5 (gas coolers & intercoolers)
  • Verified natural gas duty: up to 330 barg
  • Scope: gas process skids & CNG stations
  • Spares: HP bundles, manifolds, gaskets, louvers

Combustion Air Preheaters 2.1

Series 2.1 combustion air preheaters use steam, condensate, water or thermal oil on coal, oil, biomass and 2×350 MW power boilers plus refinery heaters. Built with embedded, welded or galvanized finned tubes under ASME codes. Spare items cover coil bundles, fins and headers.

  • Series: 2.1 (steam / condensate / water / oil)
  • Power plant reference: 2×350 MW boiler units
  • Fin types: embedded, welded, hot-dip galvanized
  • Design code: ASME & national pressure standards

Flue & Process Gas Heaters 2.2

Series 2.2 cross-flow flue and process gas heaters use bare or finned tubes under ASME and national pressure codes. Verified biomass plant steam bundles operate at 160 barg and 400 °C. Spare parts include high-pressure tube bundles, tube sheets, manifolds and gaskets.

  • Series: 2.2 (cross-flow gas heater bundles)
  • Verified duty: 160 barg at 400 °C
  • Streams: combustion flue gas & process gas
  • Spares: HP tube bundles, tube sheets, gaskets

Economizers & Superheaters 3.1–3.2

Series 3.1 water/condensate economizers (up to 116 barg and 336 °C) and 3.2 steam superheaters operate in boiler and refinery flue gas lines. Built from carbon steel, stainless steel, refractories and nickel alloys. Replaceable parts include tube coils, return bends and housing panels.

  • Series: 3.1 (economizers), 3.2 (superheaters)
  • Verified 3.1 duty: 116 barg and 336 °C
  • Alloys: carbon steel, stainless, nickel alloys
  • Spares: tube coils, return bends, housing panels

Waste Heat Recovery Units 3.3

Series 3.3 gas-gas and gas-liquid heat recovery units capture thermal energy from gas turbines, combustion engines and process gases. They heat water, superheated water, oil or process air, often with non-pressurized sides. Spare parts cover tube banks, dampers, bellows and headers.

  • Series: 3.3 (gas-gas & gas-liquid recovery)
  • Sources: gas turbines, engines, process exhaust
  • Heated media: water, thermal oil, process air
  • Spares: tube banks, dampers, bellows, headers

Finned & Bare Tube Coils 4.1–4.2

Series 4.1–4.2 heavy-duty finned or bare tube coils handle heating, cooling and dehumidification in chemical, pulp, solvent recovery, urea, textile, wood and food dryers, plus turbine sealing air coolers. Built to customer drawing or Uniterm design as drop-in coil assemblies.

  • Series: 4.1 (process plants), 4.2 (dryers/turbines)
  • Sectors: chemical, urea, pulp, textile, wood, food
  • Design: finned or bare tube coil banks
  • Spares: drop-in coil assemblies, frames, flanges

UNITERM SRL Equipment Series & Project Sizing

Founded on OTAM S.r.l. finned-tube heritage since 1959 with over 17,000 heat exchangers installed worldwide, UNITERM SRL designs custom gas-gas and gas-liquid heat exchangers in Cologno Monzese (Milan).

The portfolio spans 1.1–1.2 steam and solvent air condensers, 1.3–1.4 liquid and lube oil coolers (down to MDTM -53 °C), 1.5 compressed gas intercoolers (up to 330 barg), 2.1–2.2 combustion air and gas heaters (up to 160 barg, 400 °C), 3.1–3.3 boiler economizers and waste heat recovery units (up to 116 barg, 336 °C) and 4.1–4.2 finned/bare tube coils.

Engineering selection requires process-side fluid, mass flow, inlet/outlet temperatures, allowable pressure drop, ambient dry/wet bulb conditions and applicable pressure design code (ASME or national standards).

Materials, Fin Geometry & Industrial Applications

Heat transfer bundles are manufactured from carbon steel, stainless steel, nickel alloys and refractory materials with bare or embedded, welded and hot-dip galvanized finned tubes tailored to acidic flue gas or high-pressure hydrocarbon service.

Complete units and drop-in replacement bundles are engineered for power boilers (including 2×350 MW plants), cogeneration, biomass, waste-to-energy, refineries, chemical, pulp and paper, urea and industrial drying lines.

UNITERM SRL and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of UNITERM SRL and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.