HV Diagnostics High-Voltage Test Equipment — VLF, Tan Delta, PD and Oil Testers
Selection and quotation for HV Diagnostics Inc. test systems: oil-free HVA series VLF/DC hipots up to 200 kV, Tan Delta and PD diagnostics, BA-75/BA-100 oil testers, EZ-Cable ID, and Digi-Bridge.
HVA Series VLF and DC Hipot Testers (HVA28TD–HVA200)
Oil-free VLF and DC testers from HVA28TD (29 kV) and HVA34 up to HVA200 (200 kV) test MV cables, motor windings, and vacuum bottles. True RMS metering records load capacitance, resistance, and current. Replaceable items cover shielded HV leads, ground cables, and RS-232 adapters.
- Peak output voltage: 29 to 200 kV (21 to 141 kVrms)
- Capacitive load @ 0.1 Hz: 0.5 to 6.0 uF by model
- Burn-on-arc fault conditioning up to 5 minutes
- HVA Control Center v3.14 software via RS-232 / USB
Tan Delta Cable Diagnostics (TD30, TD60-MC–TD120-MC)
Standalone TD30 (24 kVrms) and modular TD60-MC through TD120-MC (up to 85 kVrms), plus integrated HVA-TD units, assess XLPE, EPR, and PILC cable aging. Measurements pinpoint water treeing, moisture ingress, and splice tracking. Spare components include MC HV interconnects and Bluetooth modules.
- Models: TD30, TD60-MC, TD90-MC, TD120-MC, HVA-TD
- Tan Delta resolution 1e-5, accuracy +/- 1e-4
- Minimum 5,000 pF load capacitance for TD testing
- TD Control Center v3.23 and HVD Control Center v3.70
Partial Discharge and Combo PD/TD Systems (PD30-E–PD120-2/TD)
Partial discharge instrument PD30-E (34 kV) and combo PD60-2/TD, PD90-2/TD, and PD120-2/TD systems (up to 120 kV) pair with HVA VLF units. They localize voids and splice or termination defects under HVD Suite control. Serviceable parts include HV filters, coupling capacitors, and coaxial leads.
- Models: PD30-E, PD60-2/TD, PD90-2/TD, PD120-2/TD
- PD30-E localization: 0.1 m resolution, 1% accuracy
- Simultaneous field VLF, Tan Delta, and PD diagnostics
- Configured and analyzed via HVD Suite software
Automatic Dielectric Oil Testers (BA-75 and BA-100)
Automatic oil testers BA-75 (75 kVrms, 22 kg) and BA-100 (100 kVrms, 32 kg) measure dielectric breakdown of transformer, tap-changer, and breaker oils. Built-in color LCD, temperature sensor, Bluetooth, and printer. Replaceable items cover ASTM/IEC cells, electrodes, and batteries.
- Max output voltage: 75 kVrms (BA-75), 100 kVrms (BA-100)
- Built-in ASTM and IEC international test sequences
- AC or battery operation with Bluetooth and USB PDF
- BA Control Center v3.02 and optional ASTM/IEC cells
Cable Identification and Phasing System (EZ-Cable ID)
The EZ-Cable ID system identifies one, two, or three cables or cores and locates phases under the jacket along LV, MV, and transmission lines. Works on energized or de-energized XLPE, EPR, PVC, and PILC cables without removing grounds. Spare parts include inductive clamps, signal leads, and clips.
- Simultaneous 1 to 3 core and under-jacket phase ID
- Displays 50/60 Hz load current via inductive clamps
- Applicable to point-to-point and branched cable networks
- Exempt from annual calibration requirements per FAQ
Cable Fault Location Bridges and TDR (Digi-Bridge, Tracker Pro)
The automatic HV bridge Digi-Bridge, Tracker Pro, and TDR 1205CXA pinpoint insulation and jacket/sheath faults, including on tape-shielded cables where thumpers struggle. Used in commissioning and outage recovery. Replaceable parts cover HV bridge leads, sheath probes, and coaxial TDR cables.
- Digi-Bridge: automatic insulation and sheath testing
- TDR 1205CXA: time domain reflectometry for dead shorts
- Permanent test van and trailer rig integration support
- Tracker Pro for fault tracing and cable verification
Sizing HVA VLF Testers by Cable Capacitance and Voltage Class
Select an HVA unit by multiplying cable capacitance per unit length by circuit length at 0.1 Hz. For example, HVA34 drives 0.5 uF at 24 kVrms and 0.1 Hz, while HVA30-7 handles up to 6.0 uF at 24 kVrms; lowering frequency to 0.05 Hz doubles testable cable length.
For cables over 2,000 m or voltages above 60 kVrms, HVA90 and HVA120 require a 220/240 VAC 50/60 Hz (3 kVA) supply, and high-output HVA120 and HVA200 systems can be permanently integrated into test vans or trailers with inverters and safety interlocks.
Combining VLF, Tan Delta, PD, Oil Testing, and Fault Location
HVA VLF sources form the high-voltage building block for standalone Tan Delta modules (TD30, TD60-MC to TD120-MC) and PD/TD systems (PD30-E, PD60-2/TD to PD120-2/TD) running TD Control Center v3.23, HVD Control Center v3.70, and HVD Suite.
Substation and utility fleets also deploy BA-75 (75 kVrms) and BA-100 (100 kVrms) dielectric oil testers with ASTM/IEC sequences, EZ-Cable ID for energized 1 to 3 core phase verification without removing grounds, and Digi-Bridge for sheath fault localization.
HV Diagnostics and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of HV Diagnostics and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for HITROL
- Equipment and parts for Ohmite / Ohmite Manufacturing
- Equipment and parts for SOTAX
- Equipment and parts for Schleuniger
- Equipment and parts for LumaSense Technologies
Documents and sources
- HV Diagnostics Inc. official website — equipment overview and US headquarters
- HVA Series VLF/DC hipot cable testers catalog (HVA28TD–HVA200)
- Cable diagnostics systems — Tan Delta and Partial Discharge (TD, PD)
- Dielectric oil breakdown testers BA-75 and BA-100
- EZ-Cable ID cable identification and phasing system
- Cable fault location bridge Digi-Bridge and Tracker Pro
- HV Diagnostics calibration, repair, and test van integration services
- Technical FAQs on HV test leads, software versions, and VLF/TD limits
- Current HV Diagnostics product lineup available for quotation