HANLA IMS Equipment — Level Gauges, Sensors, VRCS & EcoGuardian
Marine and industrial instrumentation from HANLA IMS (formerly Hanla Level): RLG/FLG level gauges, PL-40 transmitters, TLP-100, CT-180, HGS-100 gas detection, VRCS, and EcoGuardian BWTS.
Level Gauges RLG, FLG, HB-SPCG & FW-DF
HANLA IMS RLG, FLG, HB-SPCG, and FW-DF level gauges cover local level indication for water, fuel, and oil tanks in marine and plant service. The RLG flat glass line operates up to 50 kg/cm2 and 300 C. Replaceable parts include borosilicate glasses, gaskets, floats, and isolating valves.
- RLG-LP/HP/TB: up to 50 kg/cm2, 300 C, SUS304 column
- FLG-FA/FB/FCG/MS/MT: float & magnetic up to 120 kg/cm2
- HB-SPCG-B150/V150: 1-50 m depth, ±1.0% accuracy, SUS304
- FW-DF: dial float gauge 0-6 m range, ±15 mm accuracy
Level Switches FMS, DMS, OMS & TMR
HANLA IMS FMS, DMS, OMS, and TMR switches monitor high and low limits across HFO, diesel, lube oil, sludge, and water tanks. TMR reed units offer up to 6 switching points with IP56 or Exd IIC T6 protection. Service spares cover floats, reed tubes, microswitches, and chambers.
- FMS-H/V: 10 kg/cm2, 180 C, 250 VAC 5 A, IP56 / Exd IIC T6
- DMS/OMS: 220-5000 mm range, up to 41 bar / 400 C
- TMR/HTUM: up to 6 points, SUS304/316/PVC, IP68 options
- FWS-3P, RN 3000, CAP 63, HVPS: flow, solids & oil-in-water
Transmitters PL-40, FLT-100, CER-8000 & Radar
Hydrostatic PL-40 (PL40-I-P), ceramic CER-8000, and magnetic float FLT-100 transmitters output 4-20 mA signals with ±0.2% accuracy. EM540 and PS60 radars support Modbus RTU up to 70 m. Spare parts include ceramic cells, vented cables, reed chains, and amplifier boards.
- PL40-I-P / PL-40: 0-19.99 mH2O, 4-20 mA, IP68, ATEX Ex ia
- FLT-100: magnetic float up to 30 m, 4-20 mA / HART, 5 mm step
- CER-8000: 0-350 bar, 96% Al2O3 ceramic diaphragm, ±0.2%
- EM540 / PS60: 10 GHz FMCW & C/K-band radar up to 70 m
Tank Systems TLP-100, CT-180, LIDEC & Dynamic-A
TLP-100 Hall IC gauges, CT-180 air-purge systems, and Dynamic-A IAMCS automate cargo and ballast monitoring. High/overfill safety and bulk hold protection use TMR-701T/702T, CMS-LIDEC, and HWID. Spares cover I.S. barriers, AU-160D/HPI-100 modules, and probes.
- TLP-100: Hall IC sensor, 3-point Pt100 RTD, 10.4" touch LCD
- CT-180-OPN/EPN/MPN: air purge up to 40 m, 24-tank HPI-100
- TMR-701T/702T & CMS-LIDEC: 95%/98% alarm, EEx ia IIC T6
- Dynamic-A, AU-100/160/240L, HWID: IAMCS & SOLAS water ingress
Gas Detection HGS-100 & OVMS-50
HGS-100 fixed gas sampling systems monitor pump rooms, ballast tanks, and void spaces under IGC and ISGOTT rules. OVMS-50 monitors vapour line pressure (0-200 mbar) and O2 concentration (0-25%). Spares include sampling pumps, gas sensors, flame arrestors, and solenoid valves.
- HGS-100: up to 48 suction channels, 500 m copper pipe run
- HGS-100: 4x RS-485 Modbus RTU, up to 7 IR/catalytic sensors
- OVMS-50: 0-25% O2, 0-200 mbar pressure, EEx ia IIC T4
- Spares: suction pumps, water trap filters, flame arrestors
VRCS Actuators & EcoGuardian BWTS
HANLA IMS VRCS actuators and EcoGuardian BWTS (EG-0500 to EG-3000-Ex and EGNF0130 to EGNF6000) are sized by ballast pump flow rate and hazardous-area rating. VRCS combines actuators, HPUs, solenoid cabinets, and consoles. Spare parts cover TRO sensors, electrodes, and valve seals.
- VRCS: hydraulic, electric, and pneumatic valve actuators
- VRCS: hydraulic power units (HPU), solenoid cabinets & consoles
- EcoGuardian / NFTM: 130-6000 m3/h filtration & electrochlorination
- Approvals: USCG & LISCR listed Non-Ex and Ex-proof BWMS models
About HANLA IMS Co., Ltd. (formerly Hanla Level)
Established in 1989 in Busan, South Korea as Hanla Level Instrument and listed on KOSDAQ (092460), HANLA IMS Co., Ltd.
designs and manufactures marine instrumentation, tank level gauging systems, fixed gas sampling panels, valve remote control systems (VRCS), Dynamic-A integrated alarm and monitoring systems, and EcoGuardian ballast water treatment systems.
Products hold type approvals from ABS, BV, DNV, GL, KR, LR, NK, and RINA, with USCG and LISCR listings for EcoGuardian BWTS and ATEX/IECEx explosion-proof approvals for hazardous tank zones.
Technical Selection Criteria for Shipyards & Plants
When specifying RLG, FLG, PL-40, CT-180, TLP-100, or EM540/PS60 radar systems, match the measured medium, tank height (up to 70 m for radar or 50 m for content gauges), operating pressure and temperature limits, 4-20 mA / HART / Modbus RTU output requirements, and Ex-proof rating.
For VRCS packages and EcoGuardian BWTS, sizing depends on valve actuator type (hydraulic, electric, or pneumatic), required torque, ballast pump flow rate (130-6000 m3/h), and Non-Ex or Ex-proof zone classification.
HANLA IMS and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of HANLA IMS and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Zama Seter / Zama Sensor
- Equipment and parts for AirTAC
- Equipment and parts for Hangzhou Xinglong Pump
- Equipment and parts for Hangzhou Shanli Purify
Documents and sources
- HANLA IMS verified manufacturer profile (Komachine) — instrumentation, VRCS, Dynamic-A, certifications
- HANLA IMS Vol. 1 Catalog — RLG/FLG/HB-SPCG gauges, FMS/DMS/TMR switches, PL-40/FLT-100 transmitters (PDF)
- HANLA IMS Vol. 2 Catalog — EM540, PS60, TLP-100, CT-180, LIDEC, HGS-100, and HWID systems (PDF)
- LISCR Approved Ballast Water Management Systems — EcoGuardian and EcoGuardian NFTM models
- HANLA IMS corporate history (Korean Wikipedia) — established 1989, KOSDAQ 092460