QKL / Kao Lu Electronic Proportional Regulators and Flow Control Valves

Sizing and export quotation for QKL / Kao Lu (Kao Lu Enterprise / Genn Dih) proportional pressure, vacuum, and flow controllers (QKL-B1T, B1S, B3, B3-A, B4H, B3V, QKL-HS, FC-3000, PPV) with 0–10V, 4–20mA, and RS485.

Low-Pressure Regulators QKL-B1T, QKL-B1TR and QKL-B4HR

QKL-B1T closed-loop PID regulators control 0–2, 0–4, and 0–8 bar at 4–13 L/min with 0.0005 bar resolution. QKL-B1TR and QKL-B4HR reach ±0.005% F.S. step control via a 0.1 mm bleed orifice. Built for microfluidics, dispensing, and low-pressure leak testing.

  • Output 0–2 / 0–4 / 0–8 bar (B1TR: 2/5/10 bar)
  • Input & monitor: 0–10V, 4–20mA, RS485 Modbus
  • Port PT 1/8", DC 24V, M12 connector, IP65
  • Dual solenoid valves, pressure sensor, PCB

High-Flow Regulators QKL-B3, QKL-B3-A and QKL-B1H

QKL-B3 pairs dual solenoids with an internal volume booster for up to 1200 L/min at 0–8 bar and 0.1–0.25% accuracy. Economic QKL-B3-A (B3-AI) delivers 940 L/min at 7 bar for laser cutting. QKL-B1H reaches 5600 L/min at 8 bar for large chambers.

  • Flow up to 1200 L/min (B3) / 5600 L/min (B1H)
  • QKL-B3-A (B3-AI): 0–7 bar, G1/4", ±1% F.S.
  • Input: 0–10V, 4–20mA, RS485, DC 24V <=4W
  • Internal volume booster, solenoids, M12 lead

Medium-Pressure Regulators QKL-B1S and QKL-B3H (0–30 bar)

QKL-B1S regulates 0–30 bar (34 bar max inlet) at 40 L/min with 5 mV resolution for gauge calibration and leak testing. QKL-B3H delivers up to 6000 L/min at 30 bar with 0.5 s response for blow molding. Both support external pressure sensor feedback.

  • Output 0–30 bar (435 psi), max inlet 34 bar
  • B1S: 40 L/min (PT 1/8"); B3H: 6000 L/min (G3/8")
  • Command 0–10V, 4–20mA, RS485, DC 24V supply
  • High-pressure solenoids, transducer, NBR seals

High-Pressure Regulators QKL-B4H (0–60 and 0–70 bar)

QKL-B4H-P60 and B4H-P70 control 0–60 and 0–70 bar (74 bar max supply) at up to 170 L/min. With ±0.25% F.S. accuracy and 200 ms response, they serve test rigs, MOCVD, and physical foaming. Rated for -196 to +70 °C across inert gases and compressed air.

  • Output 0–60 / 0–70 bar (max supply 74 bar)
  • Flow up to 170 L/min, ±0.25% F.S. accuracy
  • 200 ms response, temp range -196 to +70 °C
  • 0–10V / 4–20mA / RS485, 1/8" PT, IP65, 800 g

Electronic Vacuum Regulators QKL-B3V, QKL-HS1V and B4HV

QKL-B3V electronic vacuum regulators control negative pressure from 0 to -101 kPa at 250–600 L/min via dual solenoid valves, internal sensor feedback, and IP65 M12 protection. QKL-HS1V, HS2V, and B4HV extend control from -101 to +900 kPa up to 900 NI/min.

  • Vacuum 0 to -101 kPa (HS2V: -101 to +900 kPa)
  • Flow 250–600 L/min (B3V) / 900 NI/min (HS2V)
  • Accuracy ±0.5% F.S. (B3V) / ±0.2% F.S. (HS1V)
  • Dual solenoids, vacuum sensor, G1/4", IP65

High-Speed 3/2 Proportional Regulators QKL-HS0, HS1 and HS2

QKL-HS 3/2 directly actuated seating regulators combine a proportional solenoid, pressure transducer, and programmable electronics for fast pressure switching up to 100 bar. Flow reaches 11,000 NI/min with <0.1% FS linearity, supporting air, hydrogen, and oxygen.

  • Pressure up to 0–50 bar (HS0/1) and 0–100 bar (HS2)
  • Flow up to 11,000 NI/min @ 30 bar, <0.1% FS
  • Signals: 0–10V, 4–20mA, RS485, IO-Link option
  • Proportional solenoid, refined spool, FKM/FFKM

Flow Control Valves FC-3000, KLPV and QKL-CLC Controller

Stepper-driven FC-3000 needle valves modulate 0–5000 L/min air or 0–94 L/min water across -1 to 20 bar with ±0.1% F.S. repeatability. KLPV proportional solenoids cover 0–300 L/min with PWM tuning. QKL-CLC adds 12-bit PID closed-loop control via RS485.

  • FC-3000: 0–5000 L/min air, 0–94 L/min water
  • Pressure -1 to 20 bar, PT 1/2", Viton or FFKM
  • KLPV solenoid: 0–32 / 140 / 300 L/min via PWM
  • QKL-CLC: 12-bit PID, 0–5V, 4–20mA, RS485

Proportional Pinch Valves PPV with PM Stepper Driver

PPV-04, PPV-06, and PPV-08 proportional pinch valves modulate flow or pressure by squeezing flexible tubing (3.5–9 mm O.D., heavy-duty up to 1" O.D.) with zero fluid contact. Built for clinical analyzers, dosing, and bioprocessing. Driven by PM controllers over 0–10V, 4–20mA, or RS485.

  • PPV-04 (3.5–4.5 mm), PPV-06 (5.5–7 mm), PPV-08 (7–9 mm)
  • High-torque versions support tubing up to 1" O.D.
  • PM driver: 0–10V, 4–20mA, or RS485 Modbus input
  • Non-contact sterile pinching, quick tube slot

Closed-Loop Architecture of QKL / Kao Lu Regulators

Kao Lu Enterprise Co., Ltd. / Genn Dih Enterprise Co., Ltd. (founded in 1980 in Taichung, Taiwan) builds QKL electronic proportional regulators around dual inlet/exhaust solenoid valves, an internal or external pressure transducer, and a high-speed PID microprocessor board.

For high-flow dynamic lines, QKL-B3, QKL-B1H, and QKL-B3H integrate internal volume boosters, while QKL-HS 3/2 direct-acting seating valves support air, hydrogen, and oxygen up to 100 bar.

Selecting Pressure Range, Flow Capacity and PLC Interfaces

Model selection starts with target pressure (from -101 kPa vacuum on QKL-B3V up to 70 bar on QKL-B4H or 100 bar on QKL-HS2), required ANR flow rate, port threading (PT 1/8", G1/4", G3/8", PT 1/2"), and wetted materials.

Control and feedback options cover 0–10 VDC, 4–20 mA, RS485 Modbus, and IO-Link over 24 VDC with IP65 M12 cabling. Clean dry compressed air filtered to 5 um is recommended for long-term stability.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.