Hansen Technologies Industrial Refrigeration Valves & Controls
Engineering selection and export of Hansen Technologies MVP valve stations, HS solenoid valves, HA4A/CARW regulators, Pop-Eye relief valves, Auto-Purgers, and Vari-Level controls.
MVP13–MVP100 Multi-Valve Stations
Hansen MVP stations combine shut-off, solenoid, regulator, and check functions in one body. Removing flange gaskets reduces refrigerant leak risk on evaporators. MVP20–MVP50 add five gauge ports and a 3/4 inch pilot port. Connections span 1/2 to 4 inch in FPT, SW, BW, and ODS.
- Port sizes: 1/2"–4" (13–100 mm)
- Gauge ports: 5 on MVP20–MVP50
- Side pilot port: 3/4" NPT
- Ends: FPT, SW, BW, ODS
Solenoid Valves HS2, HS4A, HS6, HS7, HS8A
Hansen solenoid valves serve liquid, suction, and hot-gas defrost lines in refrigeration loops. Stainless pistons with Teflon seals resist sticking in low-oil systems. Units handle 300 psi (20 bar) MOPD with removable tubes. One standard encapsulated coil fits all Hansen valves.
- Series: HS2, HS4A, HS4D, HS6–8A
- MOPD rating: 300 psi (20 bar)
- Teflon disc and stainless trim
- Universal low-wattage coil
Pressure Regulators HA4A, HA4AM, HA2A, CARW
Modular regulators control inlet, outlet, or differential pressure across evaporators and vessels. HA4A and CARW series handle ammonia, halocarbon, and subcritical CO2 circuits. Compact HA2A and HA2B models fit small branch lines. Replaceable control modules simplify tuning.
- Series: HA4A, HA4AM, HA2A, HA2B
- Modulating series: CARW
- Inlet, outlet, delta-P control
- Modular pilot kits
Motorized MCV & Pulse Valves PXV / PXVW
Hansen MCV motorized valves (1/2 to 4 inch) use IP67 actuators rated at 800 psig weld-in-line or 400 psig flanged. PLC inputs accept 4–20 mA, 0–10 V, and dry contacts. PXV and PXVW60 pulse valves handle 15 to 60 tons of ammonia. PXVW60 integrates a 100-mesh (150-micron) strainer.
- MCV: 1/2"–4", 800 psig SWP, IP67
- Inputs: 4–20 mA, 0–10 V, 24 V
- PXVW60: 15–60 tons, 100 mesh
- Coils: 115 V, 220 V, 24 V AC
Safety Relief Valves H56xx Pop-Eye & EZ-SRV
H56xx relief valves and EZ-SRV cartridges conform to ASME UV and ANSI/ASHRAE 15 codes. Pop-Eye detection blinks a 360-degree LED for over two weeks on a 7+ year battery. Rupture disc assemblies with switches are also offered. Discharged valves require prompt replacement.
- Series: H56xx Pop-Eye, EZ-SRV
- Code: ASME UV & National Board
- 360° lift LED (7+ yr battery)
- Rupture discs & pressure switches
Check Valves HCK & Industrial Shut-Off Valves
Hansen check valves include HCK1 piston, HCK4 inline, HCK4LR gravity drain, and HSCK combination stop-check units. They mount in any orientation with low opening pressure differentials. Industrial shut-off valves are produced in threaded, socket-weld, and butt-weld ends for ammonia and CO2.
- Check: HCK1, HCK4, HCK4LR
- Stop-check combination: HSCK
- Shut-off: Threaded, SW, BW
- Low opening pressure drop
Auto-Purger Non-Condensable Gas Removers
Auto-Purger units vent air to lower condensing pressure and compressor load. APWT models purge 8, 16, or 24 ammonia points with a touchscreen HMI and NEMA 4 enclosure. Compact APM/APMF serve up to 4 points and 200 tons (703 kW). APP and NEAP complete the range.
- APWT: 8, 16, or 24 points (NH3)
- APM/APMF: 4 pts, 200 tons (703 kW)
- Touchscreen HMI & water bubbler
- APP & NEAP mini auto-purgers
Vari-Level Controls, Gas Detectors & Pump Guardian
Vari-Level controls and WLT probes handle up to five relay set points in a NEMA 4 (IP65) housing. HLL float switches seal a 10 A SPDT contact in inert gas. Gas detectors monitor ammonia and CO2 via 4–20 mA signals. Pump Guardian protects pumps via thermistors and RS232.
- Vari-Level: up to 5 relays, IP65
- HLL: 10 A SPDT, 3/4" FPT / 1" BW
- Gas detector: NH3, CO2, 4–20 mA
- Pump Guardian: thermistor & RS232
Selection of Hansen Technologies Industrial Valves & Controls
We configure Hansen Technologies industrial refrigeration valves, MVP stations, Auto-Purger units, Vari-Level controls, and rebuild kits for ammonia, CO2, and halocarbon systems.
Specification covers refrigerant compatibility, port sizing from 1/2 to 4 inch, FPT/SW/BW/ODS end connections, and safe working pressures up to 800 psig weld-in-line.
PLC Integration & ASME Safety Compliance
Hansen MCV motorized valves (IP67) and PXV/PXVW60 pulse expansion valves integrate directly with plant PLCs via 4–20 mA, 0–5 V, 0–10 V, and dry-contact signals.
H56xx Pop-Eye and EZ-SRV pressure relief devices meet ASME Boiler and Pressure Vessel Code (UV stamp) and ANSI/ASHRAE 15 safety mandates.
Purging Efficiency & Level Monitoring Systems
APWT Auto-Purgers handle 8, 16, or 24 ammonia purge points with touchscreen HMI and NEMA 4 protection, while APM/APMF cover medium systems up to 200 tons (703 kW).
Vari-Level probes with up to five set-point relays, HLL inert-gas float switches, and Pump Guardian RS232 controllers protect evaporators and liquid recirculation loops.
Hansen Technologies and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Hansen Technologies and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for ZOOK Enterprises
- Equipment and parts for Wilspec Technologies
- Equipment and parts for Instrument Technology / ITI
- Equipment and parts for ZEN Group / ZEN Bearings
Documents and sources
- About Hansen Technologies — valves and controls overview
- Hansen Technologies USA and China (Nantong) locations
- MVP Valve Stations — port sizes and specifications
- Hansen Solenoid Valves series catalog
- HS2 Solenoid Valve — 300 psi MOPD and standard coil
- Hansen Pressure Regulators series catalog
- Pressure Relief Valves and EZ-SRV catalog
- POP-EYE self-alerting safety relief valves
- Hansen Auto-Purgers non-condensable gas removers
- APWT Auto-Purger — 8, 16, and 24 purge points
- APM and APMF Auto-Purger up to 200 tons (703 kW)
- Motorized Control Valves — 800 psig and IP67 specs
- PXV & PXVW pulse modulating expansion valves
- Hansen Level Controls and transducer probes
- Vari-Level Adjustable Level Control specs
- Refrigerant Float Switch HLL series
- Hansen Check Valves HCK and HSCK series
- Hansen Shut-Off Valves end connections
- Hansen Gas Detector — NH3, CO2, 4-20mA output
- Pump Guardian refrigerant pump controller
- Hansen Technologies China portal