Seren IPS RF Generators and Matching Networks

Seren IPS (USA): M125, R, L and HR RF generators from 125 W to 30 kW at 100 kHz to 60 MHz, AT and ATS automatic matching networks, RFS switch boxes and filters.

HR601, HR1001 and HR2501 RF Generators

HR1001 delivers 1000 W at 1.7–2.1, 13.56, 27.12 or 40.68 MHz, specified when ordering; a 1200 W version runs at 13.56 MHz. HR601 gives 600 W, including a 60 MHz version. HR2501 gives 2500 W at 13.56 MHz in a 3U full rack package. All three are air cooled.

  • HR1001: 1000 W
  • HR1001 version: 1200 W
  • HR601 version: 60 MHz
  • HR2501: 2500 W

HR2001, HR3001 and HR5001 RF Generators

The water cooled HR2001 (2000 W) and HR3001 (3000 W) come at 1.7–2.1, 13.56, 27.12 and 40.68 MHz. HR5001 (5000 W) is offered at 350–460 kHz, 1.7–2.1, 3.2, 13.56, 27.12 and 40.68 MHz. HR2001 needs 2 GPM of water at 40 °C and runs on 200–240 V single or three phase or 380–415 V.

  • HR2001: 2000 W
  • HR3001: 3000 W
  • HR5001: 5000 W
  • HR2001 water: 2 GPM at 40 °C

HR10001, HR20001 and HR30001 RF Generators

HR10001 (10 kW), HR20001 (20 kW) and HR30001 (30 kW) run at 13.56, 27.12 or 40.68 MHz on three phase power, including 480 V. Water cooling takes 2 GPM at 40 °C on HR10001 and 4 GPM on HR20001 and HR30001. HR20001 and HR30001 are modular master, slave and combiner systems.

  • HR10001: 10,000 W
  • HR20001: 20,000 W
  • HR30001: 30,000 W
  • HR20001 water: 4 GPM

M125, R301, R601 and R1001 RF Generators

M125 gives 125 W at 13.56 MHz with forward, net power and voltage control modes. R301 gives 300 W at 13.56 MHz, R601 600 W at 1.7–2.1, 13.56, 27.12 or 40.68 MHz, and R1001 1000 W at 1.7–2.1 or 13.56 MHz. All four are air cooled half rack units.

  • M125: 125 W
  • R301: 300 W
  • R601: 600 W
  • R1001: 1000 W

L301, L601 and L1001 Low Frequency Generators

L301, L601 and L1001 give 300, 600 and 1000 W at 100–120, 200–300 or 350–460 kHz. All three are air cooled half rack units. L1001 uses 123 CFM of forced air and pulses with a 50 µs minimum pulse width.

  • L301: 300 W
  • L601: 600 W
  • L1001: 1000 W
  • L1001 pulse: from 50 µs

AT Automatic Matching Networks

The AT range runs from AT-3 (300 W, not to exceed 20 A at 2.5 kV) to AT-250/250 (15–30 kW, 250 A, water). AT10 is rated 1000 W, not to exceed 45 A at 6 kV, with a 15 pin control connector, a standard DC probe and optional peak RF and current probes. AT50/140 is a 5000 W water cooled unit.

  • AT-3: 300 W
  • AT10: 1000 W
  • AT50/140: 5000 W
  • AT-250/250: 15–30 kW

ATS and Mini Matching Networks

ATS10 is rated 1000 W at a frequency from 1.7 to 40.68 MHz set when ordering, not to exceed 45 A at 6 kV, on 24 V DC at 3 A, with an RS-232/485/422 serial port and a 25 pin analog connector. The air cooled ATS3M to ATS20M cover 300 to 2000 W at 6 kV; ATS3M runs at 13.56, 27.12 and 40.68 MHz.

  • ATS10: 1000 W
  • ATS10 supply: 24 V DC, 3 A
  • ATS3M: 300 W
  • ATS20M: 2000 W

RF Switch Boxes, Filters and Controls

RFS switch boxes come in 2, 3 or 4 way versions at 7 or 17 A on 24 V DC. LPF low pass filters are rated 600 to 10000 W, and BPF band pass filters reject 13.56, 27.12 or 40.68 MHz. The range also has DMO-4 and DMO-16 master oscillators, the PCS2 phase shifter, PSRS for HR and the MC2 AT controller.

  • RFS4-17: 17 A
  • LPF2S10K: 10000 W
  • BPF1K: 1 kW
  • DMO-16: 16 channels

Selecting Seren IPS Generators and Matching Networks

Seren IPS Inc. (Vineland, NJ, USA) builds RF generators, matching networks and accessories for RF power delivery and offers dedicated application and design engineering services. The series follows power: M125 gives 125 W, R and L up to 1000 W, HR from 600 W to 30 kW.

Frequency is specified when ordering: L at 100–120, 200–300 or 350–460 kHz, HR1001 at 1.7–2.1, 13.56, 27.12 or 40.68 MHz, and HR601 also at 60 MHz.

A matching network is chosen by power and current, from AT-3 at 300 W and 20 A to AT-250/250 at 15–30 kW and 250 A; package, controls, probes and outputs are made to order.

Interfaces and Connection

HR1001, R601, L1001 and M125 use a DB-9 serial port and a DB-25 analog connector; analog interface pinouts for the RLx01, HR and M series and MC2 network controller I/O are published by the maker. HR1001 pulses at 0–100 % duty with a 10 µs minimum pulse width.

ATS10 runs on 24 V DC and has an RS-232, RS-485 or RS-422 serial port and a 25 pin analog connector. AT10 has a 15 pin control connector, a standard DC probe and optional peak RF and current probes.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.