T&C Power Conversion RF Generators, Tuners and Transformers

T&C Power Conversion (USA): 13.56 and 27.12 MHz RF generators, 10 kHz to 20 MHz broadband sources, AIT-600 matching networks, RFSB switchboxes, impedance transformers and DCM supplies.

AG 0x13 13.56 MHz RF Generators

AG 0x13 generators and amplifiers run at 13.56 MHz with 100 W to 2400 W across the series. Interfaces are analog/digital, RS-232 and USB, with automatic and manual gain control and high speed pulsing. The 1000 W units are air cooled, the 1200 W and 2400 W units water cooled.

  • AG 0x13 frequency: 13.56 MHz
  • Series power: 100–2400 W
  • AG 0613: 600 W
  • Interfaces: RS-232, USB

27.12 MHz RF Generators

T&C 27.12 MHz generators come in 300 W, 600 W and 1000 W air-cooled and 1200 W and 2400 W water-cooled versions. The design is compact, for rack mount or stand-alone use. They are aimed at industrial, medical and R&D applications; spec sheets are published for 300 W and 600 W.

  • Frequency: 27.12 MHz
  • Air cooled: 300, 600, 1000 W
  • Water cooled: 1200, 2400 W
  • Spec sheets: 300 and 600 W

AIT-600 RF Matching Networks

T&C 13.56 MHz matching networks handle 100 W to 2400 W and work with any 13.56 MHz RF power source. The AIT-600 automatic impedance tuner comes in 300, 600 and 1000 W, the R-Series in 600, 1200 and 2400 W, and a manual tuner is offered. The tuners use air and vacuum capacitors.

  • Frequency: 13.56 MHz
  • AIT-600: 300, 600, 1000 W
  • R-Series: 600, 1200, 2400 W
  • Tuner capacitors: air and vacuum

RFSB RF Switchboxes

The T&C RF switchbox distributes power from one AG 0x13 generator and matching network system into multiple plasma applications, one source-to-load at a time. RFSB-1-2, RFSB-1-3 and RFSB-1-4 have one input and 2, 3 or 4 outputs. Switching uses 24 V (18 to 26 V) via DB-15.

  • Outputs: 2, 3 or 4
  • Current at 13.56 MHz: ≤ 17 A
  • Voltage at 13.56 MHz: ≤ 8 kV peak
  • Control: 24 V, DB-15

Class A Broadband RF Sources

The T&C Class A broadband series spans 10 kHz to 20 MHz and offers low harmonic distortion and a clean output signal. AG 1017L delivers 500 W over 10 kHz to 15 MHz, AG 1015 delivers 1000 W over 10 kHz to 10 MHz. T&C impedance transformers are compatible with the Class A sources.

  • Class A band: 10 kHz–20 MHz
  • AG 1017L: 500 W
  • AG 1015: 1000 W
  • AG 1015 band: 10 kHz–10 MHz

Class AB Broadband RF Sources

The T&C Class AB series covers 10 kHz to 15 MHz with higher harmonic distortion than Class A. AG 1006 and AG 1007 give 300 W, AG 1016 600 W, AG 1010 and AG 1012 1000 W, and AG 1024 2000 W over 15 kHz to 3 MHz. A separate high voltage AG 0201HV-OS gives 140 W at 200 to 450 kHz.

  • AG 1010: 1000 W
  • AG 1012 band: 20 kHz–8 MHz
  • AG 1024: 2000 W
  • AG 0201HV-OS: 140 W

T01–T4K RF Impedance Transformers

T&C low frequency impedance transformers are step-up or step-down units for 10 kHz to 3 MHz and 100 W to 4000 W, matching 1.2 to 2500 ohms with up to 7 outputs. T01 covers 0.4 to 2 MHz at 100 W continuous; T03 50 to 500 kHz at 300 W; T2K 10 kHz to 3 MHz at 2000 W; T4K 10 kHz to 1 MHz at 4000 W.

  • Matching: 1.2–2500 ohms
  • T01: 100 W continuous
  • T2K: 2000 W continuous
  • T4K: 4000 W continuous

DCM and DCMP DC Power Supplies

The DCM DC power supply comes in 750 W, 1000 W and 1500 W for low power magnetron sputtering or as a bias supply in RF sputtering and RF etching. The 1500 W DCMP pulse DC supply allows pulsing of 10 kHz to 300 kHz at 3 to 70 % duty. Both are compact full rack mount units.

  • DCM: 750, 1000, 1500 W
  • DCMP: 1500 W
  • DCMP pulsing: 10–300 kHz
  • DCMP duty: 3–70 %

Selecting T&C Power Conversion RF Sources

T&C Power Conversion, Inc. (Rochester, NY, USA) builds high and low frequency RF power generators and amplifiers, RF matching networks and transformers, complete 13.56 MHz RF delivery systems and RF switchboxes.

Its fields include ultrasonics, thin film deposition, CVD, PVD and gas plasma generation.

Frequency sets the series: AG 0x13 generators and AIT-600 tuners run at 13.56 MHz, a separate line at 27.12 MHz, and AG 10xx broadband sources cover 10 kHz to 20 MHz. Custom sources use a built-in DDS signal source and front panel meters for forward, reverse and load power.

Base models include the 100 W LA 2030 linear amplifier.

Revisions, Setup and Repair

The generator revision is read from the front panel: CXN is the post-2017 revision, C9N has a large white display, and each has its own GUI software and serial port programming guide. The interlock is set by enabling one jumper.

Quickstart guides cover the 13.56 MHz generator and tuner and the low frequency AG series. A repair request lists the unit and model number, serial number and failure description; equipment is not sent back before an RMA number is issued.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.