Spellman High Voltage Power Supplies and X-Ray Generators
Spellman (USA): SL rack mount supplies of 1–130 kV, UM modules, XRV X-ray generators of 160–450 kV and HFe of 40–80 kW, the XRB160PN480/1 Monoblock®, ECHUCK and EBM-FEG supplies and PFE-HV equipment.
SL Series Rack Mount Supplies
SL rack mount supplies cover 1 kV to 130 kV and 10 W to 1200 W with positive, negative or reversible polarity; reversible is standard up to 8 kV. A resonant inverter gives greater than 85% efficiency. The 1200 W model runs on 200/220 Vac only; the eSL option adds a VFD panel and Ethernet.
- SL voltage: 1–130 kV
- SL power: 10–1200 W
- Reversible: up to 8 kV
- Efficiency: over 85 %
UM Series PCB Mount Modules
UM modules mount on a printed circuit board and come in 8 voltage ranges from 62.5 V to 6 kV, fixed negative or positive polarity, at 4, 20 or 30 W. Zero voltage switching is used, units are fully arc and short circuit protected, and current limits at 103% of rating. Voltage is set by 0 to 4.64 Vdc.
- UM range: 62.5 V–6 kV
- UM power: 4, 20, 30 W
- Current limit: 103 %
- Programming: 0–4.64 Vdc
XRV Industrial X-Ray Generators
XRV industrial X-ray generators come in 160, 225, 320, 350 and 450 kV models at 1.8 kW to 6 kW, with negative, positive or bipolar output. Two filament supplies give 0 to 6 A; USB, Ethernet, RS-232 and analog are standard. 1.8–4.5 kW models take 180–264 Vac single phase, 6 kW models 208 or 400 Vac.
- XRV voltage: 160–450 kV
- XRV power: 1.8–6 kW
- Filament: 0–6 A
- Cooling: forced air
XRB160PN480/1 Monoblock X-Ray Source
The XRB160PN480/1 Monoblock® integrates the HV supply, filament supply, X-ray tube, beam port and control electronics. Tube voltage is 80 kV to 160 kV and tube current 0.25 mA to 3 mA; the glass tube has a tungsten target and a 0.8 × 0.8 mm focal spot. Analog and RS-232 interfaces.
- Tube voltage: 80–160 kV
- Tube current: 0.25–3 mA
- Focal spot: 0.8 × 0.8 mm
- Beam: fan 80° × 10°
HFe Medical X-Ray Generators
HFe high frequency X-ray generators from Spellman Germany serve radiography and fluoroscopy at 40, 50, 65 or 80 kW. Radiographic units take single or three phase input; fluoroscopic units are three phase and power 1 or 2 tubes. Isolated circuit breakers power down generator sections one at a time.
- HFe output: 40, 50, 65, 80 kW
- Modes: radiography, fluoroscopy
- Fluoroscopy: 1 or 2 tubes
- Fluoroscopy input: 3 phase
ECHUCK Electrostatic Chuck Supplies
ECHUCK (ESC) supplies power electrostatic chucks in wafer processing. Type 1 has a ground referenced output from +2 kV to -5 kV, 2 mA at +2 kV and 5 mA at -5 kV. Type 2 has a floating bipolar output of 0 to ±750 Vdc (1500 Vdc total) at 5 mA. Input is +24 Vdc, with up to 10 cycles per second.
- Type 1: +2 to -5 kV
- Type 2: 0 to ±750 Vdc, 5 mA
- Input: +24 Vdc
- Cycle rate: up to 10 per second
EBM-FEG Field Emission SEM Supply
EBM-FEG is an integrated tetrode supply that drives field emission SEM columns. The main acceleration voltage is a high stability 30 kV supply (-20 V to -30 kV) with integrated floating filament, extractor and suppressor outputs. Control is via fiber optic RS-232; input is +24 Vdc, weight 20 kg.
- Acceleration: 30 kV
- Outputs: filament, extractor, suppressor
- Control: fiber optic RS-232
- Weight: 20 kg
PFE-HV Power Feed Equipment
PFE-HV is high voltage power feed equipment for long submarine cable installations in telecom. Versions are 6, 9, 12, 15 and 18 kV, up to 22.5 kW for n+1 converter redundancy, input -40.5 to -60 Vdc. A data logger captures data every 10 ms; a converter can be replaced while the PFE powers the cable.
- Versions: 6–18 kV
- Power: up to 22.5 kW
- Redundancy: n+1
- Data logging: every 10 ms
Selecting Spellman High Voltage Supplies
Spellman High Voltage Electronics Corporation (USA), established in 1947, builds precision DC high voltage power supplies, X-ray generators and Monoblock® X-ray sources.
The catalog is split into modules, rack mount supplies, X-ray generators, Monoblocks®, portable X-ray imaging products and application specific units.
The series follows the task: SL rack mount supplies of 1–130 kV for analytical X-ray, electrostatics, e-beam systems, general laboratory and hipot testing; UM PCB modules up to 6 kV; XRV industrial X-ray generators of 160–450 kV; HFe medical generators of 40–80 kW; ECHUCK supplies for wafer chucks; PFE-HV for submarine cables.
Service and Factory Repair
For factory repair Spellman asks for the model and serial numbers from the rear panel of the power supply and the reason for return; every return needs an RMA or SVO number.
Manufacturer service programs include a global repair network, preventative maintenance, calibration, recycling and repair and high voltage training courses.
HFe generators have isolated circuit breakers so service engineers can power down sections of the generator one at a time. In PFE-HV a converter can be replaced while the equipment still powers the cable, and the converters have n+1 redundancy.
Spellman and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Spellman and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Comet Group
- Equipment and parts for XP Power
- Equipment and parts for T&C Power Conversion
- Equipment and parts for MDC Precision
Documents and sources
- Home page — product lines
- About Spellman — company profile
- Brands — company history
- Product catalog — categories
- Service and technical support — returns
- SL Series — product page
- UM Series — product page
- XRV Series — product page
- XRB160PN480/1 Monoblock — product page
- HFe Series — product page
- ECHUCK Series — product page
- EBM-FEG — product page
- PFE-HV Series — product page