BioLogic Potentiostats and Battery Cyclers

BioLogic is a French electrochemical instrument manufacturer based in the Grenoble area, with a history dating back to 1983: potentiostats, battery cyclers, scanning workstations and fuel cell test stations.

Premium potentiostats VMP-300, SP-300 and SP-200

The VMP-300 is a modular chassis with 16 slots for potentiostat, EIS and booster boards. The SP-300 is a two-channel unit with a 500 mA to 10 A range, the SP-200 a compact single-channel unit for in-situ work. EIS reaches 11 MHz, the ULC option goes down to ±1 pA.

  • VMP-300: 16 slots
  • EIS up to 11 MHz
  • ULC option down to ±1 pA
  • Calibration board, 100+ points

Essential potentiostats VMP-3e, VSP-3e, SP-150e and SP-50e

The VMP-3e holds 16 channels, the VSP-3e 8, the SP-150e two and the SP-50e one. Channel current is ±1 A; on the VMP-3e, VSP-3e and SP-150e it extends to 800 A with FlexP0012 boosters. EIS covers 10 µHz to 1 MHz, and range modules are added in-situ by the user.

  • VMP-3e: 16 channels
  • ±1 A per channel
  • Up to 800 A with boosters
  • EIS up to 1 MHz

High-current potentiostats HCP-803, HCP-1005 and boosters

The HCP-803 combines a research-grade potentiostat and an 80 A booster in one chassis for fuel cells and supercapacitors. The HCP-1005 delivers ±100 A at 0.6–5 V for Li-ion cells. The FlexP0012 booster gives -200/+195 A, and four units in parallel reach -800/+780 A.

  • HCP-803 up to 80 A
  • HCP-1005 up to ±100 A
  • FlexP0012: -200/+195 A
  • Overheat shutdown at 70 °C

BCS-900 Premium battery cyclers

The BCS-900 series consists of BCS-905, BCS-910, BCS-915 and BCS-975R modules with 8 independent channels each. Channel current is ±150 mA, ±1.5 A, ±15 A and ±75 A respectively, and the BCS-975R reaches 300 A in parallel for pouch and prismatic cells. EIS is optional on each module.

  • 8 channels per module
  • Up to ±75 A per channel
  • Up to 300 A in parallel
  • Optional EIS per module

BCS-1012 battery cyclers and MPG-200 research systems

The Essential BCS-1012 is built for high-volume aging studies: 32 channels at ±6 A in an 8U module, with a 0 V to 5 V range. The MPG-200 series serves R&D labs: the MPG-2 has 16 channels at 100 mA, the MPG-205 8 channels at 5 A, with or without EIS.

  • BCS-1012: 32 channels
  • Up to ±6 A per channel
  • MPG-2: 16 channels, 100 mA
  • MPG-205: 8 channels, 5 A

M470 scanning electrochemistry workstation

The modular M470 supports 9 local electrochemistry techniques for mapping sample surfaces. The scan range is 110 × 110 × 110 mm with closed loop positioning and a zero hysteresis encoder. It integrates an SP-300 potentiostat with EIS from 10 µHz to 3 MHz.

  • 9 local techniques
  • 110 mm travel on 3 axes
  • Built-in SP-300 potentiostat
  • EIS up to 3 MHz

BluPEM test station and BluRev rotating electrodes

BluPEM is a PEM fuel cell test station rated up to 100 W as standard and customizable up to 2 kW. H2 flow reaches 3 L/min, cell temperature 20 °C to 100 °C. BluRev RDE and RRDE electrodes rotate from 100 to 10,000 rpm, the RRDE up to 9,000 rpm.

  • Cells up to 2 kW
  • H2 flow up to 3 L/min
  • Cell 20 °C to 100 °C
  • Up to 10,000 rpm

SFM-4000 stopped-flow and MOS-500 spectrometer

SFM-4000 stopped-flow systems mix two, three or four solutions and record the kinetics of fast reactions. Dead time is down to 200 µs with the microvolume cuvette; the mixing ratio varies from 1:1 to 1:100. The MOS-500 spectropolarimeter measures circular dichroism from 163 to 950 nm.

  • Dead time from 200 µs
  • Mixing ratio 1:1 to 1:100
  • Up to 4 syringes, 3 mixers
  • CD from 163 to 950 nm

Selecting BioLogic potentiostats by current and channel count

The instrument depends on channel count, current and EIS range. One or two channels are covered by the SP-50e, SP-150e, SP-200 and SP-300, multichannel work by the 8-channel VSP-3e and the 16-channel VMP-3e and VMP-300. Premium units add EIS up to 11 MHz and ultra low current ranges.

High-capacity cells and fuel cells need the 80 A HCP-803, the ±100 A HCP-1005 or FlexP0012 boosters up to -800/+780 A. Electrical properties of materials are measured with the MTZ-35 impedance analyzer from 10 µHz to 35 MHz.

Battery cyclers and research workstations

Cell aging and cycling studies use BCS-900 cyclers with 8-channel modules from ±150 mA to ±75 A or the BCS-1012 with 32 channels at ±6 A. MPG-200 lab systems run 16 channels at 100 mA or 8 channels at 5 A.

Local surface electrochemistry is studied on the M470 workstation, PEM fuel cells on the BluPEM station up to 2 kW, and fast reaction kinetics on SFM-4000 stopped-flow systems.

BioLogic and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of BioLogic and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.