Maccor Battery Test Systems
Maccor manufactures battery test equipment in Tulsa, Oklahoma, USA, since 1987: cabinets with 1–192 channels, a research platform, desktop testers, cell formation systems and temperature chambers.
Series 4000 and 4000H battery test systems
Series 4000 floor-standing cabinets test cells, modules and packs for cycle life, performance and qualification. A system has 1 to 96 channels, up to 1,400 A and 14,400 W with 1 or 4 current ranges. The Series 4000H supports up to 2,400 A and 28,800 W.
- 1 to 96 channels
- Series 4000 up to 1,400 A
- Series 4000H up to 2,400 A
- Minimum step 2 ms
Series 6500 high-power module and pack testers
The Series 6500 is built for high-power EV module and pack testing. It delivers up to 3,200 A and 16,000 W in a compact footprint. It has 3 current ranges, a 10 ms minimum step and the full options suite of the 4000 platform.
- Current up to 3,200 A
- Power up to 16,000 W
- Three current ranges
- Minimum step 10 ms
Series 6600 high-density cell testers
The Series 6600 is a high-density cell tester with the features of the Series 4000 in a compact design. One system has 1 to 192 channels at up to 1 A with 4 current ranges. The minimum step is 20 ms and the full options suite is available.
- 1 to 192 channels
- Up to 1 A per channel
- Four current ranges
- Minimum step 20 ms
Series 6000 battery research platform
The Series 6000 is designed for pulse and impedance research on new cell chemistries. It samples at 20 kHz with 1 μs pulse resolution and ±0.02 % of full scale voltage and current accuracy. Test steps start at 500 μs and waveforms reach 15,000 levels.
- Sampling rate 20 kHz
- Pulse resolution 1 μs
- Accuracy ±0.02 % FS
- Minimum step 500 μs
Series 4200, 4300, 4400 and 6200 desktop testers
Desktop testers pack Series 4000 hardware into a compact footprint and run the same MacTest32 software as the cabinets. The four-range Series 4400 reaches ±30 nA on the bottom range. The Series 4200 and 6200 provide 16 channels at up to 240 A.
- 1 to 16 channels
- Series 4400 ±30 nA
- Series 4200 up to 240 A
- Minimum step 2, 5 or 10 ms
Series 5302 cell formation systems
The Series 5302 runs the first charge and discharge of new cells on production lines and recycles power back to the grid. It has up to 2,048 independent channels per system, a 100 % duty cycle and 0.02 % of full scale voltage accuracy. Grading covers capacity, IR and self-discharge.
- Up to 2,048 channels
- Duty cycle 100 %
- Voltage accuracy 0.02 %
- Cells 18650, 21700, 4680
FUSION integrated test systems
FUSION combines a Maccor cycler, an AES environmental chamber and safety controls in one unit that is factory acceptance tested before shipment. Safety controls include emergency stop, smoke and gas detection and venting. Configurations include 192 channels at 1 A and 64 channels at 15 A.
- Factory acceptance tested
- 192 channels at 1 A
- 64 channels at 15 A
- Emergency stop, gas detection
Temperature chambers for battery testing
The compact heat and cool chamber is controlled as a step in the Maccor test procedure, with no separate chamber software. The range is +10 °C to +100 °C with ±0.5 °C accuracy. One system controls up to 32 chambers, and up to four fit into a 19-inch rack.
- Heat and cool +10…+100 °C
- Accuracy ±0.5 °C
- Up to 32 chambers per system
- Up to four chambers per rack
Selecting Maccor test systems by current and channel count
The platform depends on the device under test and the current.
Series 4000 cabinets with 1–96 channels and up to 1,400 A suit cells and small modules, while high-power modules and packs need the Series 4000H up to 2,400 A or the Series 6500 with up to 3,200 A. For high-volume cell testing the Series 6600 offers 1–192 channels at 1 A.
Pulse and impedance research is served by the Series 6000 with 20 kHz sampling and 1 μs pulse resolution; labs with limited floor space use desktop testers with 1–16 channels.
Cell production and temperature-controlled testing
On production lines the Series 5302 runs the first charge and discharge on 2,048 channels with grading by capacity, IR and self-discharge. It supports cylindrical 18650, 21700 and 4680 cells, prismatic hard-shell and pouch cells.
Temperature-controlled tests run in Maccor chambers from +10 °C to +100 °C or in FUSION systems that combine the cycler, an AES chamber and safety controls in one unit.
Maccor and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Maccor and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for LEAD Intelligent
- Equipment and parts for Labthink
- Equipment and parts for GW Instek
- Equipment and parts for AMETEK Brookfield
- Equipment and parts for Ophir
Documents and sources
- Series 4000, 4000H, 6500 and 6600 — manufacturer page
- Series 6000 platform — manufacturer page
- Desktop testers — manufacturer page
- Series 5302 formation systems — manufacturer page
- FUSION integrated systems — manufacturer page
- Temperature chamber — manufacturer page
- Options and add-ons — manufacturer page
- Accessories and calibration tools — manufacturer page
- Software suite — manufacturer page
- Service and calibration — manufacturer page
- About Maccor — company page