Equipment and parts for Haskel
Select liquid pumps, gas boosters, air amplifiers and valves against the medium, operating point and required system scope.
M, MS and 29723 liquid pumps
Compact air-driven pumps generate liquid pressure for testing and charging circuits. M, MS, 29723 and MDSTV cover different wetted constructions. Pump selection includes the plunger, check valves and seal materials.
- 0.33 hp air drive
- Spring return on M models
- Stainless steel wetted construction on MS
- Model-specific check valves and seals
Industrial liquid pumps, 2 and 2.2 hp
AW, ASF, DSF and high-pressure configurations serve test and process circuits. Select the drive arrangement and pressure ratio against the operating point. Replacement requires matching the plunger, check valves and seal materials.
- 2 and 2.2 hp families
- AW, ASF, DSF, HF and HSF
- Application-specific pressure ratios
- Replaceable plungers, valves and seals
AG, AGD and AGT gas boosters
Air-driven boosters raise gas pressure for transfer, charging and testing. AG, AGD and AGT differ in piston action and staging. Oxygen needs special cleaning, while hydrogen requires an appropriate model and gas-section configuration.
- AG: single acting
- AGD: double acting
- AGT: two stages
- Select gas-section and drive seals separately
H-Drive and Q-Drive gas systems
H-Drive uses hydraulic power for sustained gas compression. Q-Drive combines electric servo actuation with a controller and operator interface. Integration covers cooling, gas connections and access to replaceable seal assemblies.
- Hydraulic H-Drive
- Servo-electric Q-Drive
- Single- and two-stage configurations
- Cooling and controls specified with the system
AA, AAD and AAT air amplifiers
Air-powered amplifiers boost pressure at the point of use. HAA31 and AA are single acting, AAD is double acting and AAT uses two stages. Replacement assemblies include pilot valves, the cycling spool and piston seals.
- Single-stage HAA31 and AA
- AAD, 4AAD-2 and 8AAD-2
- Two-stage AAT
- Size for pressure and total air demand
59015 and 59020 refrigerant pumps
Pneumatic refrigerant pumps handle liquid and vapor during transfer and recovery. The 59015 and 59020 serve these phase-changing duties. Selection includes seal compatibility and downstream overpressure protection.
- Models 59015 and 59020
- Liquid and vapor transfer
- Air-driven operation
- Downstream pressure-relief protection
BuTech valves, fittings and repair assemblies
BuTech components control liquid and gas flow in high-pressure lines. The 30UV, 30V, 40UV and 60UV valve families have replacement assemblies. Select the stem, packing and repair kit from the complete valve designation.
- Needle and check valves
- Fittings, tubing and filters
- Replacement stem and packing kits
- Match cone-and-thread connection geometry
Pressure and flow at the operating point
SpareX sources equipment and replacement assemblies for Haskel systems from a defined process requirement. The operating point combines medium, available inlet pressure, required outlet pressure and flow. A stall-pressure rating does not describe the rate at which a vessel will fill.
Filling a volume and then holding pressure are separate duties.
Pneumatic performance depends on the pressure and air flow available at the drive connection. An air amplifier consumes drive air as well as supplying useful outlet air, so the required plant-air capacity includes both.
Long running periods are subject to the manufacturer's cycle-rate and cooling guidance rather than the extreme point on a performance curve. A receiver supplies brief peak demand from stored air and recharges between cycles.
These inputs allow alternative configurations to be compared under the same operating conditions.
Liquid and wetted construction
M, MS, 29723 and MDSTV configurations differ in their wetted construction and sealing arrangements. For water, hydraulic oil, solvents or a process liquid, wetted materials must suit the actual fluid conditions. Composition and temperature determine compatibility beyond a general fluid name.
An existing pump configuration defines the replacement assembly, including special options.
A bare pump and a packaged pumping station have different supply boundaries. The assembly boundary covers the drive, check valves, controls and connections. Air-drive kits, liquid-section kits and valve assemblies have distinct functions.
Physical separation of the drive and liquid section also separates their sealing requirements. Connection geometry, mounting constraints and maintenance access determine the installation interfaces.
Gas conditions and compression stages
AG, AGD and AGT selection depends on gas, inlet pressure and required delivery. When recovering gas from a cylinder bank, the inlet pressure changes as the source empties. The end-of-transfer condition also affects sizing.
Two-stage performance depends on pressure distribution across both stages as well as final outlet pressure. Duty cycle and gas purity also affect configuration.
Oxygen duties require an appropriate cleaning specification, while hydrogen service needs a suitable model and configuration. Those conditions determine gas-section, seal and connection specifications.
The application also matters: a pressure-test rig, occasional cylinder charging and a continuous process supply place different demands on the equipment. Cooling, vent routing, isolation and pressure measurement are part of the system boundary.
A gas name alone is insufficient to establish the suitability of a complete booster installation.
Hydraulic and servo-electric drives
H-Drive depends on its hydraulic power source; Q-Drive depends on electrical supply, controls and cooling services. Available utilities and the choice of module or packaged system establish the supply boundary.
Q-Drive includes a controller and operator interface; the operating sequence must work with the plant's control system.
The H24-63 brochure lists a minimum inlet pressure of 100 psi, or 6.9 bar, a maximum outlet of 15000 psi, or 1034 bar, and a maximum compression ratio of 6:1. These are separate model limits.
Their combined effect determines the operating point; maximum outlet cannot be assumed at every inlet pressure. Q-Drive requires external cooling and service clearance. Sensors, gas connections and control signals form part of a complete working system beyond its compression assembly.
Valves and line protection
BuTech valve and connection selection depends on medium, flow path and operating conditions. Model configuration, cone geometry, thread arrangement and tubing size determine connection compatibility. Replacement stems, packing kits and repair kits serve different purposes.
A change in valve configuration also requires a review of the adjoining components and their connection geometry.
59015 and 59020 refrigerant duties involve liquid and vapor handling, seal compatibility and downstream line protection. The manufacturer recommends downstream pressure relief because pressure can intensify at stall.
Isolation valves, check valves and pressure-relief devices have separate functions within the station. Instrument locations, process connections and recovered-refrigerant handling determine the installation interfaces.
This keeps the equipment boundary clear when the pump is supplied as one component of a larger recovery system.
System boundary and acceptance criteria
The system boundary determines which functions are included in the package. A bare booster may use existing plant instruments and valves, while an assembled station needs an agreed piping and control arrangement.
Pumping or compression hardware, controls, cooling and protective devices are separate specification items. Each new-equipment interface must work with the components remaining in service. This makes configurations technically comparable beyond their main pump designation.
Acceptance criteria follow the actual cycle: filling, pressure buildup, pressure holding or continuous delivery. Each duty has its own parameters and applicable documentation. Control functions and responses to design signals form part of system acceptance.
A station must fit the agreed process arrangement, including its connection and utility boundaries. Packaging and preservation also depend on the destination and the cleanliness requirements of the internal gas or liquid passages.
Industrial liquid-pump duty
Selection of 2 and 2.2 hp pumps depends on pressure ratio, displacement and load profile. AW, ASF, DSF, HF and HSF configurations have different liquid-section constructions. Filling duty needs flow; holding duty requires pressure retention.
Nominal horsepower alone does not determine the right pump. Curves describe performance at defined drive pressures and media, with separate continuous and intermittent duties.
A changed application also requires a review of air preparation, regulation, supply piping and valves, so the replacement scope includes the components that limit delivery.
Air demand and process boundaries
Source capacity must match process demand. An air amplifier's useful output is additional to its drive-air consumption. Peak demand involves both delivery and pressure recovery between cycles. Liquid-pump performance also depends on suction-line conditions and pumping-section filling.
A meaningful comparison uses matching conditions, beyond maximum pressure alone. The control circuit, pressure measurement and actuators form part of the station specification. A functioning booster does not by itself establish the performance of the complete installation.
Haskel and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Haskel and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
Documents and sources
- Liquid pumps: operation and selection
- M, MS, 29723 and MDSTV compact pumps
- Industrial 2 and 2.2 hp pumps: models and materials
- Gas boosters: drives and configurations
- H24 hydraulic gas boosters: brochure
- Q-Drive servo-electric gas systems
- Air pressure amplifier families
- Air amplifiers: performance curves and sizing
- Refrigerant transfer and recovery pumps
- Replacement parts and seal selection
- Seal-kit installation instructions
- BuTech high-pressure valves and connections
- Hydraulic gas boosters: Chinese brochure