Tool-Temp Equipment — Temperature Control Units and Chillers

Swiss-engineered Tool-Temp AG temperature control units for water (up to 90 °C and pressurized 160 °C), thermal oil (up to 360 °C), and CLASSIC Cool industrial chillers (4.5–259 kW) with MP-888, MP-988, and IRIS controls.

CLASSIC Duo Universal Units (90/150 °C)

CLASSIC Duo units (TT-181, TT-188, 90/150 12 E/H) serve plastics molding with water up to 90 °C and oil up to 150 °C. Heating spans 9–12 kW on water or 3–6 kW on oil with 7–20 L tanks. Replaceable parts cover circulation pumps (4–5 bar), heater banks, heat exchangers, and FeKo Type J probes.

  • Water up to 90 °C / oil up to 150 °C
  • Tank 7–20 L, heating 9–12 / 3–6 kW
  • Pump pressure 4–5 bar, 40–41 l/min
  • MP-888 controller, FeKo Type J

MATIC Duo Automated Units (IRIS)

MATIC Duo (90/150 9 E, 18 E, 18 H, 18 E P, 18 H P) combines 9–18 kW heating, 7–20 L tanks, and IRIS automation for water (90 °C) and oil (150 °C). Frequency-controlled pumps deliver 4.6–7 bar at 52–62 l/min. Service spares include 7-inch IRIS displays, IO1–IO3 modules, and PT-100 probes.

  • Water up to 90 °C / oil up to 150 °C
  • Heating 9–18 kW, tank 7–20 L
  • Pump 4.6–7 bar, 52–62 l/min
  • IRIS controller, PT-100 sensor

Water Temperature Control Units up to 90 °C

CLASSIC Water (TT-170 L, TT-1548 E, TT-1500 W, TT-1368 W/V) and MATIC Water 90 (18–45 K) cover compact molds to large tooling up to 580 l/min. Units provide 3–144 kW heating and 5–100 L tanks. Available spares include centrifugal pumps, mechanical seals, heaters, and heat exchangers.

  • Water temperature up to 90 °C
  • Heating 3–144 kW, tank 5–100 L
  • Flow 19–580 l/min, 2.9–4.6 bar
  • MP-888/MP-988 or IRIS control

Pressurized Water Units (130–160 °C)

CLASSIC Water (TT-1398 N, 140 12 N/NN, TT-138 N, TT-1358 W, TT-DW 160) and MATIC Water 160 (12 B, 24 B) run in closed tankless loops (0 L) at 130–160 °C. Heating spans 6–48 kW with up to 6.5 bar pump pressure. Spares include high-pressure seal pumps, relief valves, and heat exchangers.

  • Pressurized water 130–160 °C
  • Closed tankless loop (0 L)
  • Heating 6–48 kW, flow 36–250 l/min
  • Pump pressure 3.8–6.5 bar

CLASSIC Oil High-Temperature Units (200–360 °C)

CLASSIC Oil high-temperature units (TT-390, TT-390/2, TT-510 X, TT-708 Y, TT-407/409/410 Z) circulate thermal oil at 200 to 360 °C with tank volumes from 8 to 200 L and heating capacities from 8 to 144 kW. Spares cover leak-free oil pumps, staged heater banks, solenoid valves, and level switches.

  • Thermal oil 200–360 °C, dual /2
  • Heating 8–144 kW, tank 8–200 L
  • Pump 3.8–5.5 bar, up to 500 l/min
  • MP-888 / MP-988, Type J or PT-100

MATIC Oil Automated Units with IRIS (200–360 °C)

MATIC Oil units (200 12 A/Z P, 300 12 A/Z, 350 48 X N, 360 16–48 Z, and dual-zone 360/2) operate with thermal oil up to 360 °C in automated molding cells. Heating runs 12–48 kW with flow up to 415 l/min. Service spares cover A/Z oil pumps, PT-100 probes, tubular heat exchangers, and IRIS modules.

  • Thermal oil 200–360 °C, dual /2
  • Heating 12–48 kW, tank 9–75 L
  • Flow 72–415 l/min, 4.2–5.5 bar
  • IRIS + PT-100, OPC UA Euromap 82.1

CLASSIC Cool Industrial Chillers (4.5–259 kW)

CLASSIC Cool chillers (TT-5'500 to TT-216'000) come in air-cooled and water-cooled Standard (R-134a, +10..+40 °C), Performance HP (R-407C, +10..+30 °C), and Eco LG (R-1234yf, GWP < 4) variants. Cooling spans 4.5–259 kW. Spares include compressors, condensers, pumps, and PT-100 probes.

  • Cooling 4.5–259 kW, +10 to +40 °C
  • R-134a, R-407C (HP), R-1234yf (LG)
  • Air-cooled & water-cooled designs
  • Tank 25–600 L, pressure 4.5–8.5 bar

Control Systems IRIS, MP-888, and MP-988

The 24 V DC IRIS system features a 7-inch PCAP IPS screen (1024×600, 1000 cd/m², IP54, IK06) with OPC UA Euromap 82.1, RS-232/485, CAN, Profibus, Profinet, and Ethernet/IP. MP-888 and MP-988 (230 V) provide PID control and 25-point ramp profiles. We source HMI panels, IO1–IO3 modules, and cables.

  • IRIS: 7" IPS 1000 cd/m², IP54/IK06
  • OPC UA Euromap 82.1, Profinet, CAN
  • MP-888/MP-988: 230 V PID regulation
  • MP-988: 25-point / 8-curve ramp

CLASSIC (MP-888/MP-988) vs. MATIC (IRIS) Control Architecture

Tool-Temp AG, founded in 1973 and manufacturing in Sulgen, Switzerland, builds two control lines: CLASSIC units with 230 V MP-888 or MP-988 PID controllers (including 25-point ramp profiles on MP-988) and MATIC units equipped with the modular 24 V DC IRIS system.

IRIS integrates a 7-inch 1024×600 PCAP IPS screen (IP54, IK06), frequency-controlled pump modes, and OPC UA Euromap 82.1, Profinet, Profibus, Ethernet/IP, CAN, RS-232/485, and analog 0–10 V / 0/4–20 mA interfaces.

Selecting Water (90/160 °C), Oil (200–360 °C), and Dual-Zone Units

Standard water units (CLASSIC Water and MATIC Water 90) cover 3–144 kW heating and flow rates up to 580 l/min, while closed tankless pressurized water units (TT-1398 N, TT-138 N, TT-DW 160, MATIC Water 160) reach 130–160 °C at up to 6.5 bar.

Thermal oil units (CLASSIC Oil and MATIC Oil, including dual-circuit /2 models such as TT-390/2 and MATIC Oil 360/2) reach 200–360 °C with 8–200 L tanks and up to 144 kW heating for high-temperature molding, extrusion, and roll heating.

CLASSIC Cool Industrial Chillers: Standard, HP, and Eco LG

CLASSIC Cool units span TT-5'500 through TT-216'000 in air-cooled and water-cooled configurations with 25–600 L tanks, 4.5–8.5 bar pump pressure, and 4.5–259 kW nominal cooling capacity.

Standard units use R-134a for ambient air up to +45 °C (+10..+40 °C fluid), Performance HP uses R-407C for higher capacity at +10..+30 °C, and Eco LG uses low-GWP R-1234yf (GWP < 4).

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.