Totton Pumps — Industrial Magnetic Drive & Diaphragm Pumps

Non-metallic magnetically coupled centrifugal (NEMP, NDP, GP), regenerative (HPR), semi-submersible column (SPC), 12/24V DC, and multi-chamber diaphragm (AD) pumps for clean chemical and cooling fluids.

NEMP Heavy-Duty Magnetic Drive Centrifugal Pumps

The heavy-duty NEMP series covers 35 to 500 l/min in completely non-metallic chemical-resistant PP or PPS thermoplastics for leak-free continuous transfer of acids, alkalis, solvents, and chilled fluids. Motors use IP54/IP55 enclosures. Spares cover ceramic spindles and O-rings.

  • Models: NEMP 25/5, 20/30 IV, 40/6, 50/7, 60/6, 80/6
  • Wetted parts: PP or PPS body, alumina ceramic spindle
  • Motors: IP54/IP55, 230/110V 1ph or 20/30 IV 0-10V DC
  • Spares: PP magnets, thrust washers, EPDM/Viton O-rings

NDP Compact Magnetic Drive Centrifugal Pumps

The NDP range delivers 10 to 35 l/min for circulation and transfer of chemicals and chilled water in laboratory, print, X-ray, and compact industrial equipment. Model NDP 35/3 reaches 35 l/min at 50 Hz across -20 to +85 deg C. Replaceable parts include spindles, impellers, and O-rings.

  • Models: NDP 14/2, NDP 25/2, NDP 25/4, NDP 35/3
  • Drip-proof IP22 motors, 110/230V 50/60Hz options
  • Wetted parts: PP or PPS housing, PP encapsulated magnet
  • Ports: 13 mm or 22 mm plain tails, 1/4 and 1/2 BSP M

HPR High-Pressure Regenerative Magnetic Pumps

HPR magnetically coupled regenerative pumps (1 to 10 l/min, PPS pump head, Nitrile O-rings, IP54 housing) serve high-pressure recirculation of carbonated and de-ionized water. Model HPR 10/15 delivers up to 10.1 l/min at 90 W across -20 to +85 deg C. Spare parts include PPS heads and O-rings.

  • Models: HPR 6/8, HPR 6/11, HPR 10/15 (up to 10.1 l/min)
  • Pump head: chemical-resistant PPS, Nitrile O-rings
  • Thermal shield coupling preserves fluid temperature
  • Connections: 1/2 inch standard or 15 mm OD plain port

GP Water and Glycol Circulation Pumps

The GP range covers 35 to 80 l/min circulation units plus multistage high-head models for water and glycol loops. Multistage GP 20/12 delivers 17.4 l/min at up to 12.7 m head using a brass spindle and PTFE-graphite thrust washers. Maintenance spares include washers, spindles, and O-rings.

  • Models: GP 20/12 (17.4 l/min, 12.7 m head), GP 20/18
  • Wetted parts: PP/PPS housing, brass spindle, Nitrile O-ring
  • Graphite-loaded PTFE thrust washers, IP44 enclosure
  • Ports: 15 mm plain connections or 3/8 inch BSP M

SPC Semi-Submersible Column Pumps

SPC top-mounted semi-submersible column pumps deliver 2 to 18 l/min for remote chillers, coolers, vending units, and beverage python cooling loops. Model SPC51 provides up to 16.1 l/min at 50 Hz (6.4 m head) with an agitator propeller fitted. Spares include impellers, shafts, and plates.

  • Models: SPC 51, SPC 52, SPC 54, SPC 55 (2 to 18 l/min)
  • Glass-filled ABS column and body with PP impellers
  • Stainless steel shaft, nylon agitator, IPX4 motor
  • Keyhole mounting plate in PP or stainless steel

DC Magnetic and AD Multi-Chamber Diaphragm Pumps

DC series magnetic pumps (DC 15/5, 30/5, 40/10) provide 10 to 40 l/min on 12V and 24V DC with brushless motor options. Aquatec multi-chamber diaphragm pumps (AD550, AD4/90, PCQ 12/10, SD 9/38) offer self-priming and dry-running tolerance up to 89 m head. Spares include valves and O-rings.

  • DC range: 12V/24V DC, strontium ferrite magnet, PP body
  • AD550: 10 l/min, 28 m head, 15 bar max body pressure
  • AD4/90: 3 l/min, 89 m head, 20 bar max body pressure
  • Self-priming diaphragm units allow dry running

Selection Criteria for Totton Pumps Units

Accurate pump selection requires specifying target flow rate (l/min), system head (meters), fluid chemistry, and operating temperature (-20 to +85 deg C on standard magnetic series, -20 to +40 deg C on NEMP 20/30 IV).

Standard builds handle viscosities up to 30 cP and specific gravity up to 1.2, with High SG options available.

Wetted materials are matched to the pumped medium: PP, PPS, or glass-filled ABS housings, alumina ceramic, brass, or stainless steel spindles, and EPDM, Nitrile, Viton, or silicone O-rings.

Installation Limits and Replacement Wet-End Parts

Magnetically coupled centrifugal (NEMP, NDP, GP, DC) and regenerative (HPR) pumps are not self-priming and must not run dry.

Self-priming and dry-running tolerance are supported in Aquatec multi-chamber diaphragm pumps (AD550, AD4/90), while top-mounted tank cooling duties use SPC semi-submersible column units.

All Totton pumps are engineered for clean fluids free of suspended solids or abrasives. Replacement wet-end parts cover encapsulated magnet impellers, spindles, thrust washers, O-rings, agitators, and drive motors.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.