United Filtration Systems (UFS) Filters & Separators

High-efficiency compressed air, gas, sample conditioning, and liquid filtration housings, Guardian membrane separators, and replacement elements from United Filtration Systems (UFS).

Compressed Air & Gas Housings 360 / 370 / 380AHP / 385AHP

Machined anodized aluminum 380AHP (up to 1500 PSIG), 360/370 (up to 500 PSIG), and 385AHP/390AHP housings paired with 70CS coalescing elements reaching 99.99% efficiency at 0.01 micron. Float drains (>12 psi) and 2–16 psi DP gauges are optional. Spares: 70CS elements and seals.

  • Rating 500–1500 PSIG
  • 0.01 micron (70CS, 99.99%)
  • 1/4 to 2 inch ports
  • Float drains (>12 psi), 2–16 psi DP

Mini SS 5000 PSIG Sample Housings 110 / 120

Weld-free 316L stainless steel 110 and 120 series housings comply with NACE MR-01-75 up to 5000 PSIG and 900°F for gas and liquid analyzers. Compact 2-port particulate and 3-port coalescing or bypass ports ensure fast response. Service parts cover cartridges, Viton seals, and relief valves.

  • 316L SS (NACE MR-01-75)
  • Up to 5000 PSIG and 900°F
  • 2-port & 3-port bypass flow
  • Hastelloy & Monel options

Guardian Membrane Separators GMS100 / GMS170 / GMSL205

Precision 316L SS Guardian separators (up to 2200 PSIG, 70 LPM) block entrained liquids and solids before online analyzers. GMS170-4791 integrates a 50C coalescing pre-filter, while GMSL205 removes water from hydrocarbons. Service parts include bonded Viton membranes and 50C elements.

  • Up to 2000–2200 PSIG rating
  • Flow up to 70 LPM (2.5 SCFM)
  • GMS100, GMS170, GMS205, GMSL205
  • Bonded Viton O-ring membranes

CNG / NGV / LPG Fuel Filters (325ALHP & PF113)

The anodized aluminum 325ALHP assembly (3600 PSIG, 1/4 NPT) ships with a 1-micron 325ALHP-01NGV polyethylene element or 12-57-70CS coalescer for city gates. PF113 cartridges replace Parker DLS113 in FM80 modules. Service kits cover NGV coalescers and LPG housings.

  • 325ALHP rated to 3600 PSIG
  • 1-micron 325ALHP-01NGV element
  • PF113 cartridge for FM80
  • NGV & LPG service kits

Disposable Filters DIF/DIA & ADS Adsorption Dryers

Permanently welded DIF filters and DIA adsorbers use transparent nylon or virgin Kynar bodies in 2- and 3-port layouts across five grades. ADS dryer housings (up to 5000 PSIG) hold indicating silica gel (-40°F dew point) or 4A molecular sieve. Spares include DIF units, 5-micron pads, and media.

  • Welded nylon/Kynar DIF series
  • Granular media DIA adsorbers
  • ADS dryers up to 5000 PSIG
  • Dew point to -40°F (Silica/4A)

Heatable CEMS Filter Modules & Acid-Wash (AW) Elements

Heatable housings and heated filter modules with form-fitted silicone heating jackets eliminate cold spots in diesel exhaust and CEMS sampling. Acid-washed (AW) borosilicate microfiber elements scrub excess ammonia (NH3). Service spares include heating jackets, AW elements, and seals.

  • Silicone heating jacket module
  • CEMS & diesel exhaust sampling
  • AW elements for NH3 scrubbing
  • Low-pressure 316L & nylon

Filter Elements: Microfiber 70CS, LSS/CSS & 5-Layer Mesh

Along with 70CS and 50C borosilicate microfiber cartridges, UFS supplies LSS/CSS wire-screen elements and 5-layer sintered stainless mesh for heavily contaminated gas, polymer, and steam lines. Liquid streams use melt-blown depth and pleated cartridges, plus vapor adsorption cores.

  • 70CS / 50C / AW microfiber
  • LSS & CSS mesh screens
  • 5-layer sintered SS mesh
  • Melt-blown & pleated liquid

PTFE, PVDF (Kynar), Polypropylene & Exotic Alloy Housings

Corrosive chemical and low-adsorption sampling streams rely on virgin PTFE, PVDF (Kynar), polypropylene (with clear polycarbonate bowls), plus Hastelloy C, Monel 400, and Titanium housings. Service spares cover polymer bowls, PTFE-encapsulated Viton, Kalrez, EPDM, and Buna O-rings.

  • PTFE & PVDF (Kynar) bodies
  • Polypropylene & clear PC bowls
  • Hastelloy C, Monel 400, Titanium
  • Kalrez, EPDM & PTFE-Viton seals

Selecting Housing Pressure Rating & Wetted Material

Machined anodized aluminum 360A (up to 500 PSIG), 380AHP (up to 1500 PSIG), and 325ALHP (up to 3600 PSIG) assemblies pair with 70CS 0.01-micron coalescing elements for compressed air, instrument gas, and CNG.

Process analyzer and sour-gas sampling lines use weld-free 316L stainless steel 110 and 120 housings (NACE MR-01-75, up to 5000 PSIG and 900°F), or virgin PTFE, PVDF (Kynar), Hastelloy C, Monel 400, and Titanium.

Membrane Separation, CEMS Heating & Adsorption Drying

Guardian membrane separators (GMS100, GMS170-4791 with integral 50C pre-filter, and GMSL205 hydrocarbon water separators) safeguard gas chromatographs without disturbing process tubing during membrane replacement.

Heatable CEMS filter modules with silicone jackets prevent sample condensation, while ADS dryer housings (up to 5000 PSIG) reach -40°F dew points using indicating silica gel or type 4A molecular sieve.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.