GL Sciences & GL Sciences B.V. Chromatography Equipment and Columns

OPTIC-4 and OPTIC-5 multimode GC inlets (GL Sciences B.V.), CryoFocus cold traps, HandyTD TD265, PT7000, ASPE900 automated SPE, InertSustain/Inertsil/InertCap columns, and FLOM LC fluidics.

OPTIC-4 and OPTIC-5 Multimode GC Inlets (GL Sciences B.V.)

GL Sciences B.V. OPTIC-4 and OPTIC-5 multimode GC inlets support PTV, thermal desorption, and pyrolysis up to 1000 °C. CryoFocus traps focus volatiles via a silent LN2 valve. PAL3-based LINEX automates liner swapping. Spare parts include 81 × 5 mm liners, split filters, and Siltite ferrules.

  • OPTIC-5 pyrolyzer inlet rated up to 1000 °C
  • CryoFocus cold trap with silent LN2 valve
  • LINEX automatic liner exchanger on PAL3
  • 81 × 5 mm liners, split filters, Merlin seals

InertSustain, Inertsil, and InertCore HPLC / UHPLC Columns

InertSustain, Inertsil, and core-shell InertCore columns serve analytical HPLC and LC/MS workflows. Phases include C18, AQ-C18, C30, Bio C18, ODS-3V, ODS-4V, and Hybrid-Z HILIC for USP/EP and PFAS methods. Replaceable hardware covers Silfilter guard columns, PEEK hardware, and end-fitting filters.

  • InertSustain C18, AQ-C18, C30, Bio C18, Swift
  • Inertsil ODS-3V, ODS-4V, Hybrid-Z, Hybrid-Si
  • Core-shell InertCore Plus C18, Biphenyl, PFP
  • Guard cartridges, end-fitting filters, PEEK hardware

InertCap GC Capillary Columns and Injection Accessories

Low-bleed InertCap columns support GC and GC-MS analysis of volatiles, amines, pesticides, and solvents. ProGuard and T.L. series integrate built-in guard columns or transfer lines. Spares include Siltite ferrules, Merlin MicroSeal septa, μ-unions, and host-GC inlet liners.

  • InertCap 1MS, 5MS/EX, 5MS/Sil, 624MS, Pure-WAX
  • Built-in guard ProGuard and transfer line T.L.
  • TB-PLOT, WondaCap, and TC packed columns
  • Siltite ferrules, Merlin MicroSeal, μ-unions

GC Instruments: HandyTD TD265, PT7000, VPS2800, and LD249

GC hardware covers the HandyTD TD265 thermal desorber, PT7000 purge-and-trap concentrator, VPS2800 fraction collector, and Phaser Pro GC-O port. LD249 leak detectors and GF1010 flowmeters support diagnostics. Spares include TD tubes, trap tubes, and 6-port switching valves.

  • HandyTD TD265 desorber and PT7000 concentrator
  • VPS2800 fraction collector and Phaser Pro GC-O
  • LD249 gas leak detector and GF1010 flowmeter
  • Glass TD tubes, traps, 6-port valves, tubing

HPLC Hardware: CO903 Oven, ED743 Detector, and FLOM Modules

LC hardware spans the CO903 column oven, ED743 electrochemical detector, and FLOM pumps, degassers, and valves. High-pressure fluidics use MarvelXACT, VHP PK fittings, and gradient mixers. Replaceable modules cover flow cells, vacuum degasser chambers, and pump seals.

  • CO903 column oven and ED743 electrochemical detector
  • FLOM LC pumps, vacuum degassers, switching valves
  • MarvelXACT, MarvelX, and VHP PK UHPLC fittings
  • Electrode flow cells, check valves, pump seals

Sample Preparation: InertSep SPE, MonoSpin, and ASPE900 Systems

Sample prep spans InertSep SPE cartridges, QuEChERS kits, MonoSpin spin columns, and MonoTrap sorbents. Automated units include ASPE899, ASPE900, and EL870 elution systems plus SP209 air pumps. Spares cover vacuum manifolds, valveless pump plungers, tubing, and vials.

  • InertSep SPE, QuEChERS, MonoSpin, and MonoTrap
  • Automated ASPE899, ASPE900, and EL870 SPE systems
  • SP209 air sampling pump and Smart Bag PA bags
  • Vacuum manifolds, pump plungers, filters, vials

GL Sciences B.V. (Netherlands) Sample Introduction Systems

Multimode GC inlets OPTIC-4 and OPTIC-5, CryoFocus cryogenic traps, LINEX automatic liner exchangers, and Phaser Pro GC-olfactory ports are engineered and manufactured by GL Sciences B.V. in Eindhoven, Netherlands (part of GL Sciences Inc. since 2001).

These modules integrate with host GC and GC-MS instruments for large volume injection, thermal desorption, difficult matrix introduction, and pyrolysis up to 1000 °C.

Japanese Analytical Hardware and FLOM Fluidics

GL Sciences Inc. in Japan manufactures InertSustain, Inertsil, and InertCore HPLC columns, InertCap GC capillary columns, HandyTD TD265 thermal desorbers, PT7000 purge-and-trap concentrators, CO903 ovens, ED743 electrochemical detectors, and ASPE899/900 automated SPE workstations.

Tokyo-based subsidiary FLOM Corporation designs compact HPLC pumps, vacuum degassers, and multi-port valves for analytical and flow-chemistry platforms.

Configuration Inputs for Equipment Selection

To configure an OPTIC-4 or OPTIC-5 system, specify the host GC/GC-MS model, required injection modes (PTV, LVI, 3.5 × 1/4 inch TDU, or pyrolysis), and CryoFocus coolant (LN2 or CO2).

For PT7000, ASPE900, EL870, or HPLC/GC column batches, provide catalog part numbers, sample throughput, solvent compatibility, and target pharmacopeia or EPA analytical methods.

GL Sciences and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of GL Sciences and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.